Health professionals extensively use Two-Dimensional (2D) Ultrasound (US) videos and images to visualize and measure internal organs for various purposes including evaluation of muscle architectural changes. US images can be used to measure abdominal muscles dimensions for the diagnosis and creation of customized treatment plans for patients with Low Back Pain (LBP), however, they are difficult to interpret. Due to high variability, skilled professionals with specialized training are required to take measurements to avoid low intra-observer reliability. This variability stems from the challenging nature of accurately finding the correct spatial location of measurement endpoints in abdominal US images. In this paper, we use a Deep Learning (DL) approach to automate the measurement of the abdominal muscle thickness in 2D US images. By treating the problem as a localization task, we develop a modified Fully Convolutional Network (FCN) architecture to generate blobs of coordinate locations of measurement endpoints, similar to what a human operator does. We demonstrate that using the TrA400 US image dataset, our network achieves a Mean Absolute Error (MAE) of 0.3125 on the test set, which almost matches the performance of skilled ultrasound technicians. Our approach can facilitate next steps for automating the process of measurements in 2D US images, while reducing inter-observer as well as intra-observer variability for more effective clinical outcomes.
Background: Falls have high socioeconomic costs. Information and communication technologies may support provision and monitoring of multisensory (MSR) physiotherapy programmes. The HOLOBalance platform used augmented reality holograms to provide patient-centred, individualised MSR.Objectives: To determine the platform’s safety, acceptability and feasibility, investigate functional gait and dynamic balance benefits and provide data for a definitive trial.Design and setting: Single-blinded pilot randomised controlled feasibility study. Interventions were conducted at clinical sites or participants’ homes in three European countries.Participants: Community-dwelling older adults (median age 73 years; 64.2% female) at risk of falls were enrolled (May 2020-August 2021).Methods: Participants were randomised to an 8-week clinic or home-based telerehabilitation MSR or OTAGO (control group) programme. Compliance, satisfaction, and adverse events determined feasibility. Clinical outcomes, assessed (blinded) within one-week prior to and post-intervention, included functional gait assessment (FGA), Mini BESTest and cognitive function.Results: Randomisation to completion rate was 76.15% with 109 participants recruited (n = 289 screened). Drop-out rate was similar between groups. Adverse events were reported (n = 3) in the control group. Sixty-nine percent would recommend the HOLOBalance intervention. Findings were similar for the home and clinic-based arms of each intervention; data was combined for analysis. FGA (95%CI [1.63, 4.19]) and Mini-BESTest (95%CI [1.46, 3.93]) showed greater improvement in the HOLOBalance group with a clinically meaningful change of 4/30 noted for the FGA.Conclusions: HOLObalance was feasible to implement and acceptable to older adults at risk of falls, with FGA and Mini-BEST improvements exceeding those for the OTAGO programme. A definitive trial is warranted.
A “free hand” real-time-ultrasound method is commonly applied to measure transversus abdominis. Potentially, this increases transversus abdominis measurement error due to uncontrolled variability in probe to skin force, inclination, and roll, particularly for novice examiners. This single-group repeated-measures reliability study compared the intra-rater reliability of transversus abdominis thickness and activation measurement by a novice examiner between free hand and a standardized probe force device method. The examiner captured ultrasound videos of transversus abdominis in a single session in healthy participants (n = 33). Free hand ultrasound featured uncontrolled probe force, inclination, and roll, while probe force device method ultrasound standardized these parameters. Images of transversus abdominis at rest and contracted were measured and transversus abdominis activation calculated. Intraclass correlation coefficient, coefficient of variation, standard error of measurement, and worthwhile differences were calculated. The probe force device method resulted in greater reliability (intraclass correlation coefficient = 0.75–0.96) and lower measurement error (coefficient of variation = 8.89–28.7%) compared to free hand (intraclass correlation coefficient = 0.63–0.93; coefficient of variation = 6.52–29.4%). Reliability was good for all measurements except free hand TrA-C, which was moderate. TrA-C had the lowest reliability, followed by contracted thickness of the transverse abdominis, with resting thickness of the transverse abdominis being highest. Worthwhile differences were lower using a probe force device method versus free hand for resting thickness of the transverse abdominis and contracted thickness of the transverse abdominis and similar for TrA-C. Standardization using probe force device method ultrasound to measure transversus abdominis improved intra-rater reliability in a novice examiner. Use of a probe force device method is recommended to improve reliability through reduced sources of measurement error. Probe force device method intra- and inter-rater reliability in examiners of varying experience, in clinical populations, and to visualize other structures merits exploration.
Real-time ultrasound imaging (US) to measure abdominal muscle dimensions has aided low back pain rehabilitation and research. Notwithstanding, ultrasound imaging measurement of transversus abdominis muscle activation in chronic low back pain populations has been characterized by variable and generally suboptimal intra-observer reliability. Methodological deficiencies of ‘freehand’ ultrasound imaging are uncontrolled probe–skin pressure, inclination and roll of the probe. Despite previous attempts to standardize these parameters, intra-observer reliability in chronic low back pain was poor to moderate (0.32–0.62). Therefore, a standardized method that controls and records probe force, inclination and roll during ultrasound imaging may optimize measurement reliability in chronic low back pain. This pilot study investigated utility, standardization and intra-observer reliability of ultrasound imaging transversus abdominis thickness measurement in chronic low back pain patients (n = 17). Transversus abdominis imaging over two separate measurement sessions was conducted using a novel method to standardize probe parameters. Resting and contracted transversus abdominis thickness, and transversus abdominis activation measurements were obtained from duplicate paired images (n = 68). Intra-class correlation coefficients were reported with 95% confidence intervals. Transversus abdominis thickness at rest (intra-class correlation coefficient = 0.97 confidence interval: 0.93, 0.99), when contracted (intra-class correlation coefficient = 0.99 confidence interval: 0.97, 0.99) and transversus abdominis activation (intra-class correlation coefficient = 0.93 confidence interval: 0.81, 0.97) measurements were highly reliable. Ultrasound imaging of transversus abdominis using the novel standardized ultrasound imaging method produced highly reliable intra-observer transversus abdominis measurements, superior to ‘freehand’ ultrasound imaging, despite the physical limitations typically associated with a chronic low back pain population. Unique standardizing ranges for ‘probe force device’ probe parameters were obtained. This novel standardized ultrasound imaging method may optimize transversus abdominis activation assessment in chronic low back pain and other populations, aiding future research.
20 December 2016 in Journal of Back and Musculoskeletal Rehabilitation
BACKGROUND: Measurement of lumbar spine movement and neuro-dynamic flexibility is fundamental to clinical examination and forms part of most systems or protocols used to classify patients with low back pain. However, the increased age and body mass i