Jana Korte

Ms. Jana Korte


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2023 in Cardiovascular Engineering and Technology
Verified
Journal Article
Open access
PDF file
JKJana Korte
Jana Korte
SVSamuel Voß
Samuel Voß
GJGábor Janiga
Gábor Janiga
OBOliver Beuing
Oliver Beuing
DBDaniel Behme
Daniel Behme
PBPhilipp Berg
Philipp Berg
Purpose: Image-based blood flow simulations are increasingly used to investigate the hemodynamics in intracranial aneurysms (IAs). However, a strong variability in segmentation approaches as well as the absence of individualized boundary conditions (BCs) influence the quality of these simulation results leading to imprecision and decreased reliability. This study aims to analyze these influences on relevant hemodynamic parameters within IAs. Methods: As a follow-up study of an international multiple aneurysms challenge, the segmentation results of five IAs differing in size and location were investigated. Specifically, five possible outlet BCs were considered in each of the IAs. These are comprised of the zero-pressure condition (BC1), a flow distribution based on Murray’s law with the exponents n = 2 (BC2) and n = 3 (BC3) as well as two advanced flow-splitting models considering the real vessels by including circular cross sections (BC4) or anatomical cross sections (BC5), respectively. In total, 120 time-dependent blood flow simulations were analyzed qualitatively and quantitatively, focusing on five representative intra-aneurysmal flow and five shear parameters such as vorticity and wall shear stress. Results: The outlet BC variation revealed substantial differences. Higher shear stresses (up to Δ9.69 Pa), intrasaccular velocities (up to Δ0.15 m/s) and vorticities (up to Δ629.22 1/s) were detected when advanced flow-splitting was applied compared to the widely used zero-pressure BC. The tendency of outlets BCs to over- or underestimate hemodynamic parameters is consistent across different segmentations of a single aneurysm model. Segmentation-induced variability reaches Δ19.58 Pa, Δ0.42 m/s and Δ957.27 1/s, respectively. Excluding low fidelity segmentations, however, (a) reduces the deviation drastically (>43%) and (b) leads to a lower impact of the outlet BC on hemodynamic predictions. Conclusion: With a more realistic lumen segmentation, the influence of the BC on the resulting hemodynamics is decreased. A realistic lumen segmentation can be ensured, e.g., by using high-resolved 2D images. Furthermore, the selection of an advanced outflow-splitting model is advised and the use of a zero-pressure BC and BC based on Murray’s law with exponent n = 3 should be avoided.

16 February 2023 in Fluids
Verified
Journal Article
Open access
PDF file
JKJana Korte
Jana Korte
TRThomas P Rauwolf
Thomas P Rauwolf
JTJan-Niklas Thiel
Jan-Niklas Thiel
AMAndreas Mitrasch
Andreas Mitrasch
PGPaulina Groschopp
Paulina Groschopp
PBPhilipp Berg
Philipp Berg
Purpose: The analysis of pathological human left ventricular hemodynamics using high-resolved image-based blood flow simulations shows a major potential for examining mitral valve insufficiency (MI) under exercise conditions. Since capturing and simulating the patient-specific movement of the left ventricle (LV) during rest and exercise is challenging, this study aims to propose a workflow to analyze the hemodynamics within the pathologically moving LV. Methods: Patient-specific ultrasound (US) data of ten patients with MI in different stages were captured with three-dimensional real-time echocardiography. US measurements were performed while patients were resting and while doing handgrip exercise (2–4 min work). Patient-specific hemodynamic simulations were carried out based on the captured ventricular wall movement. Velocity and kinetic energy were analyzed for rest and exercise and for the different MI stages. Results: The results reveal a dependency of the kinetic energy over time in the ventricular volume curves. Concerning the comparison between rest and exercise, the left ventricular function reveals lower systolic kinetic energy under exercise (kinetic energy normalized by EDV; mean ± standard deviation: rest = 0.16 ± 0.14; exercise = 0.06 ± 0.05; p-value = 0.04). Comparing patients with non-limiting (MI I) and mild/moderate (MI II/III) MI, lower velocities (mean ± standard deviation: non-limiting = 0.10 ± 0.03; mild/moderate = 0.06 ± 0.02; p-value = 0.01) and lower diastolic kinetic energy (kinetic energy normalized by EDV; mean ± standard deviation: non-limiting = 0.45 ± 0.30; mild/moderate = 0.20 ± 0.19; p-value = 0.03) were found for the latter. Conclusion: With the proposed workflow, the hemodynamics within LVs with MI can be analyzed under rest and exercise. The results reveal the importance of the patient-specific wall movement when analyzing intraventricular hemodynamics. These findings can be further used within patient-specific simulations, based on varying the imaging and segmentation methods.

18 October 2023 in Journal of NeuroInterventional Surgery
Verified
Journal Article
Open access
PDF file
JKJana Korte
Jana Korte
FGFranziska Gaidzik
Franziska Gaidzik
NLNaomi Larsen
Naomi Larsen
ESErik Schütz
Erik Schütz
TDTimo Damm
Timo Damm
MPMariya Stanislavovna Pravdivtseva
Mariya Stanislavovna Pravdivtseva
Background The novel Contour Neurovascular System (Contour) has been reported to be efficient and safe for the treatment of intracranial, wide-necked bifurcation aneurysms. Flow in the aneurysm and posterior cerebral arteries (PCAs) after Contour deployment has not been analyzed in detail yet. However, this information is crucial for predicting aneurysm treatment outcomes. Methods Time-resolved three-dimensional velocity maps in 14 combinations of patient-based basilar tip aneurysm models with and without Contour devices (sizes between 5 and 14 mm) were analyzed using four-dimensionsal (4D) flow MRI and numerical/image-based flow simulations. A complex virtual processing pipeline was developed to mimic the experimental shape and position of the Contour together with the simulations. Results On average, the Contour significantly reduced intra-aneurysmal flow velocity by 67% (mean w/ = 0.03m/s; mean w/o = 0.12m/s; p-value=0.002), and the time-averaged wall shear stress by more than 87% (mean w/ = 0.17Pa; mean w/o = 1.35Pa; p-value=0.002), as observed both by numerical simulations and 4D flow MRI. Furthermore, a significant reduction in flow (P<0.01) was confirmed by the neck inflow rate, kinetic energy, and inflow concentration index after Contour deployment. Notably, device size has a stronger effect on reducing flow than device positioning. However, positioning affected flow in the PCAs, while being robust in effectively reducing flow. Conclusions This study showed the high efficacy of the Contour device in reducing flow within aneurysms regardless of the exact position. However, we observed an effect on the flow in PCAs, which needs to be investigated further.

11 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
JKJana Korte
Jana Korte
EKEhlar Sophie Klopp
Ehlar Sophie Klopp
PBPhilipp Berg
Philipp Berg
The Circle of Willis (CoW) describes the arterial system in the human brain enabling the neurovascular blood supply. Neurovascular diseases like intracranial aneurysms (IAs) can occur within the CoW and carry the risk of rupture, which can lead to subarachnoid hemorrhage. The assessment of hemodynamic information in these pathologies is crucial for their understanding regarding detection, diagnosis and treatment. Multi-dimensional in silico approaches exist to evaluate these hemodynamics based on patient-specific input data. The approaches comprise low-scale (zero-dimensional, one-dimensional) and high-scale (three-dimensional) models as well as multi-scale coupled models. The input data can be derived from medical imaging, numerical models, literature-based assumptions or from measurements within healthy subjects. Thus, the most realistic description of neurovascular hemodynamics is still controversial. Within this systematic review, first, the models of the three scales (0D, 1D, 3D) and second, the multi-scale models, which are coupled versions of the three scales, were discussed. Current best practices in describing neurovascular hemodynamics most realistically and their clinical applicablility were elucidated. The performance of 3D simulation entails high computational expenses, which could be reduced by analyzing solely the region of interest in detail. Medical imaging to establish patient-specific boundary conditions is usually rare, and thus, lower dimensional models provide a realistic mimicking of the surrounding hemodynamics. Multi-scale coupling, however, is computationally expensive as well, especially when taking all dimensions into account. In conclusion, the 0D–1D–3D multi-scale approach provides the most realistic outcome; nevertheless, it is least applicable. A 1D–3D multi-scale model can be considered regarding a beneficial trade-off between realistic results and applicable performance.

28 August 2025 in Computers in Biology and Medicine
Verified
Journal Article
Open access
JKJana Korte
Jana Korte
FGFranziska Gaidzik
Franziska Gaidzik
LSLena Spitz
Lena Spitz
MPMariya Stanislavovna Pravdivtseva
Mariya Stanislavovna Pravdivtseva
DBDaniel Behme
Daniel Behme
PBPhilipp Berg
Philipp Berg
The Contour Neurovascular System (Contour) is a novel device designed for the endovascular treatment of wide-necked bifurcation aneurysms (WNBAs). While clinical reports have shown promising results, some cases have failed to achieve satisfactory angiographic outcomes, and the mechanisms driving these differences remain unclear. Detailed hemodynamic analysis is critical to understanding the device's performance and optimizing treatment strategies. Based on in vivo medical images of eight patients from eight pre-, eight post-interventional, six first, and six second follow-up examinations, virtual configurations of the Contour placements were established. Based on a complex workflow, the realistic in vivo Contour deformation was virtually simulated. Subsequently, 28 patient-specific hemodynamic simulations were performed, analyzing the intra-aneurysmal blood flow in detail. Neck- and aneurysm-related hemodynamics and morphological changes in Contour and ostium over time were assessed and correlated. The Contour reduced time-averaged intra-aneurysmal velocity (TAv) and wall shear stress (TAWSS) significantly post-intervention in all cases (mean TAv: pre = 0.1 m/s, post = 0.04 m/s; mean TAWSS: pre = 0.57 Pa, post = 0.16 Pa). Long-term follow-up analysis showed a significant reduction when compared to the pre-interventional state. Due to the limitation of missing thrombus modeling, no longitudinal reduction could be derived. Uncovered ostium area was significantly related to TAv and neck inflow rate over time. In this study the immediate efficacy of the Contour on reducing flow into WNBAs based on in vivo data was demonstrated through numerical analysis. Sufficient ostium coverage by the Contour was found to be important for flow reduction in WNBAs and proper device positioning a key factor for ensuring the long-term efficacy of the Contour.

11 January 2024 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
FGFranziska Gaidzik
Franziska Gaidzik
JKJana Korte
Jana Korte
SSSylvia Saalfeld
Sylvia Saalfeld
GJGabor Janiga
Gabor Janiga
PBPhilipp Berg
Philipp Berg
Purpose: Hemodynamics play an important role in the assessment of intracranial aneurysm (IA) development and rupture risk. The purpose of this study was to examine the impact of complex vasculatures onto the intra-vessel and intra-aneurysmal blood flow. Methods: Complex segmentation of a subject-specific, 60-outlet and 3-inlet circle of Willis model captured with 7T magnetic resonance imaging was performed. This model was trimmed to a 10-outlet model version. Two patient-specific IAs were added onto both models yielding two pathological versions, and image-based blood flow simulations of the four resulting cases were carried out. To capture the differences between complex and trimmed model, time-averaged and centerline velocities were compared. The assessment of intra-saccular blood flow within the IAs involved the evaluation of wall shear stresses (WSS) at the IA wall and neck inflow rates (NIR). Results: Lower flow values are observed in the majority of the complex model. However, at specific locations (left middle cerebral artery 0.5 m/s, left posterior cerebral artery 0.25 m/s), higher flow rates were visible when compared to the trimmed counterpart. Furthermore, at the centerlines the total velocity values reveal differences up to 0.15 m/s. In the IAs, the reduction in the neck inflow rate and WSS in the complex model was observed for the first IA (IA-A δNIRmean = − 0.07ml/s, PCA.l δWSSmean = − 0.05 Pa). The second IA featured an increase in the neck inflow rate and WSS (IA-B δNIRmean = 0.04 ml/s, PCA.l δWSSmean = 0.07 Pa). Conclusion: Both the magnitude and shape of the flow distribution vary depending on the model’s complexity. The magnitude is primarily influenced by the global vessel model, while the shape is determined by the local structure. Furthermore, intra-aneurysmal flow strongly depends on the location in the vessel tree, emphasizing the need for complex model geometries for realistic hemodynamic assessment and rupture risk analysis.