Thomas P Rauwolf

Dr. Thomas P Rauwolf

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 November 2020 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Closed access
ASAlexander Schmeisser
Alexander Schmeisser
TRThomas P Rauwolf
Thomas P Rauwolf
TGThomas Groscheck
Thomas Groscheck
SKSiegfried Kropf
Siegfried Kropf
BLBlerim Luani
Blerim Luani
RBRuediger C Braun-Dullaeus
Ruediger C Braun-Dullaeus
Aims: The aim of this study was to validate the tricuspid annular plane systolic excursion/systolic pulmonary artery (PA) pressure (TAPSE/PASP) ratio with the invasive pressure–volume (PV) loop-derived end-systolic right ventricular (RV) elastance/PA elastance (Ees/Ea) ratio in patients with heart failure with reduced ejection fraction (HFREF) and secondary pulmonary hypertension (PH).Methods and results: The relationship of TAPSE and TAPSE/PASP with RV-PV loop (single-beat)-derived contractility Ees, afterload Ea, and Ees/Ea was assessed in 110 patients with HFREF with and without secondary PH. The results were compared with other surrogate parameters such as the fractional area change/PASP ratio. The association of the surrogates with all-cause mortality was evaluated. In patients with PH (n = 74, 67%), TAPSE significantly correlated with Ees (r = 0.356), inverse with Ea (r = −0.514) but was most closely associated with Ees/Ea (r = 0.77). Placing TAPSE in a ratio with PASP slightly reduced the relationship to Ees/Ea (r = 0.71) but was more closely related to the parameters of PA vascular load, diastolic RV function, and RV energetics. The area under the curve of TAPSE/PASP and TAPSE for discriminating overall survival in receiver operating characteristic analysis was not different (P = 0.78. Prognostic relevant cut-offs were 17 mm for TAPSE and 0.38 mm/mmHg for TAPSE/PASP. Both parameters in multivariate cox regression remained independently prognostically relevant.Conclusion: TAPSE is an easily and reliably obtainable and valid surrogate parameter for RV–PA coupling in PH due to HFREF. Putting TAPSE into a ratio with PASP did not further improve the coupling information or prognostic assessment.Trial Identifier: DRKS—German Clinical Trials Register (DRKS00011133; https://www.drks.de/drks_web/navigate.do?navigationId=trial.HTML&TRIAL_ID=DRKS00011133).

2 May 2021 in ESC Heart Failure
Verified
Journal Article
Open access
PDF file
ASAlexander Schmeißer
Alexander Schmeißer
TRThomas P Rauwolf
Thomas P Rauwolf
TGThomas Groscheck
Thomas Groscheck
KFKatharina Fischbach
Katharina Fischbach
SKSiegfried Kropf
Siegfried Kropf
RBRuediger C. Braun-Dullaeus
Ruediger C. Braun-Dullaeus
Aims Failure of right ventricular (RV) function worsens outcome in pulmonary hypertension (PH). The adaptation of RV contractility to afterload, the RV‐pulmonary artery (PA) coupling, is defined by the ratio of RV end‐systolic to PA elastances (Ees/Ea). Using pressure–volume loop (PV‐L) technique we aimed to identify an Ees/Ea cut‐off predictive for overall survival and to assess hemodynamic and morphologic conditions for adapted RV function in secondary PH due to heart failure with reduced ejection fraction (HFREF). Methods and results This post hoc analysis is based on 112 patients of the prospective Magdeburger Resynchronization Responder Trial. All patients underwent right and left heart echocardiography and a baseline PV‐L and RV catheter measurement. A subgroup of patients (n = 50) without a pre‐implanted cardiac device underwent magnetic resonance imaging at baseline. The analysis revealed that 0.68 is an optimal Ees/Ea cut‐off (area under the curve: 0.697, P < 0.001) predictive for overall survival (median follow up = 4.7 years, Ees/Ea ≥ 0.68 vs. <0.68, log‐rank 8.9, P = 0.003). In patients with PH (n = 76, 68%) multivariate Cox regression demonstrated the independent prognostic value of RV‐Ees/Ea in PH patients (hazard ratio 0.2, P < 0.038). Patients without PH (n = 36, 32%) and those with PH but RV‐Ees/Ea ≥ 0.68 showed comparable RV‐Ees/Ea ratios (0.88 vs. 0.9, P = 0.39), RV size/function, and survival. In contrast, secondary PH with RV‐PA coupling ratio Ees/Ea < 0.68 corresponded extremely close to cut‐off values that define RV dilatation/remodelling (RV end‐diastolic volume >160 mL, RV‐mass/volume‐ratio ≤0.37 g/mL) and dysfunction (right ventricular ejection fraction <38%, tricuspid annular plane systolic excursion <16 mm, fractional area change <42%, and stroke‐volume/end‐systolic volume ratio <0.59) and is associated with a dramatically increased short and medium‐term all‐cause mortality. Independent predictors of prognostically unfavourable RV‐PA coupling (Ees/Ea < 0.68) in secondary PH were a pre‐existent dilated RV [end‐diastolic volume >171 mL, odds ratio (OR) 0.96, P = 0.021], high pulsatile load (PA compliance <2.3 mL/mmHg, OR 8.6, P = 0.003), and advanced systolic left heart failure (left ventricular ejection fraction <30%, OR 1.23, P = 0.028). Conclusions The RV‐PA coupling ratio Ees/Ea predicts overall survival in PH due to HFREF and is mainly affected by pulsatile load, RV remodelling, and left ventricular dysfunction. Prognostically favourable coupling (RV‐Ees/Ea ≥ 0.68) in PH was associated with preserved RV size/function and mid‐term survival, comparable with HFREF without PH.

15 May 2019 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
BLBlerim Luani
Blerim Luani
CGConrad Genz
Conrad Genz
JHJoerg Herold
Joerg Herold
AMAndreas Mitrasch
Andreas Mitrasch
JMJulius Mitusch
Julius Mitusch
TRThomas P Rauwolf
Thomas P Rauwolf
Impaired renal function increases the bleeding risk, leading to a conservative prescription and frequent discontinuation of oral anticoagulation in atrial fibrillation patients with chronic kidney disease (CKD). Interventional left atrial appendage closure (LAAC) might be an alternative therapeutic strategy for these patients. We aimed to prospectively assess cerebrovascular (CE) and bleeding events, as well as peri-procedural and long-term complications in a cohort of consecutive patients undergoing interventional LAAC using the WATCHMAN™ device, with focus on CKD patients. One hundred and eighty-nine consecutive patients undergoing interventional LAAC were included in this analysis; 171 (90.5%) patients had a reduced estimated glomerular filtration rate (eGFR; patients for each CKD stage: II = 66; IIIa = 32; IIIb = 43; IV = 18; V = 12). During a follow-up of 310 patient years three (1.0%) patients suffered a CE (two strokes, one transitory ischemic attack) and five (1.6%) other ones a bleeding complication. The observed stroke rate was more than two-thirds and the bleeding risk more than half lower than expected. Device related thrombi (DRT) were detected in twelve (6.5%) patients; women had significantly more DRT than men (12.5% vs. 2.6%; p = 0.009). Patients with an eGFR< 30 ml/min/1.73m2 showed a trend to a higher DRT rate as compared to the opposite group (13.3% vs. 5.1%; p = 0.10). Thrombus resolved with temporary oral anticoagulation therapy in ten patients without sequelae; thrombus consolidation was confirmed by serial TEE controls in the remaining two patients. Atrial fibrillation patients with CKD have low CE and bleeding rates after LAAC with the WATCHMAN™ device. DRT risk is higher in female and patients with severe CKD. More frequent post-interventional TEE controls might be justified for early DRT detection and safe management of patients at high DRT risk. (German Clinical Trials Register ID: DRKS00 010768 ; Registration Date 07.07.2016).

12 December 2017 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
BLBlerim Luani
Blerim Luani
TGThomas Groscheck
Thomas Groscheck
CGConrad Genz
Conrad Genz
ITIvan Tanev
Ivan Tanev
TRThomas P Rauwolf
Thomas P Rauwolf
RBRuediger C. Braun-Dullaeus
Ruediger C. Braun-Dullaeus
Interventional closure of the left atrial appendage (LAA) in patients with non-valvular atrial fibrillation, high thromboembolic and bleeding risk or bleeding history is an alternative therapeutic strategy to oral anticoagulation. It is not known if the exclusion of the LAA from the blood circulation affects the left atrial volume (LAV) and consequently its prognostic value or the circulatory performance of the heart in humans. We aimed to prospectively assess potential changes in baseline LAV, left ventricular ejection fraction (LVEF), NT-proBNP-level and the covered distance in the 6-min walk-test 6 weeks and 6 months after LAA closure with the WATCHMAN™ device. We used serial 3-dimensional transthoracic and transesophageal echocardiography to assess LAV, residual interatrial shunt and device performance in 58 consecutive patients with successful LAA closure. Accurate 3D–echocardiographic data for LAV measurements were evaluable for 51 (91%) patients. Maximum LAV (LAVmax) at baseline was 102.8 ± 30.8 ml and increased significantly to 107.7 ± 32.8 ml after 6 weeks (p < 0.01) and 113.5 ± 34.2 ml after 6 months (p < 0.01). Minimal LAV (LAVmin) increased from 76.9 ± 29.5 ml at baseline to 81.8 ± 30.2 ml after 45 days (p < 0.01) and 82.1 ± 33.3 ml after 6 months (p < 0.01). Similarly, their indexes to BSA (LAVImax and LAVImin) increased significantly, as well. Patients without a residual left-to-right interatrial shunt showed a significantly higher increase in LAVmax or LAVmin. Baseline LVEF, NT-proBNP-level or the distance covered at the 6-min walk test did not significantly change 6 weeks or 6 months after LAA closure. LAVmax and LAVmin increase significantly after interventional LAA closure. LA enlargement does not correlate with clinical progression of heart failure. Persistent left-to-right interatrial shunt counteracts the LA enlargement. A reduced LA compliance after exclusion of the LAA from the blood circulation with consecutive increase in LA pressure may be a potential cause of LA enlargement and warrants further investigation. German Clinical Trials Register ID: DRKS00010768 ; Registration Date 07.07.2016.

11 June 2019 in Cardiovascular Ultrasound
Verified
Journal Article
Open access
PDF file
BLBlerim Luani
Blerim Luani
TRThomas P Rauwolf
Thomas P Rauwolf
CGConrad Genz
Conrad Genz
ASAlexander Schmeisser
Alexander Schmeisser
MWMarcus Wiemer
Marcus Wiemer
RBRuediger C. Braun-Dullaeus
Ruediger C. Braun-Dullaeus
A new zero-fluoroscopy technique for electrophysiology catheter navigation relying on intracardiac echocardiography (ICE) has been recently reported (Ice&ICE trial). We investigated potential differences in efficacy, safety or procedural performance between conventional fluoroscopy- and ICE-guided cryothermal ablation (CA) in symptomatic AVNRT patients. Clinical and electrophysiological data of AVNRT patients included in the Ice&ICE trial (22 patients, 16 females; =zero-fluoroscopy group) were compared to those of consecutive AVNRT patients, who underwent fluoroscopy-guided CA (25 patients, 17 females; = fluoroscopy group) during the last 2 years in our institution. Slow pathway ablation or modulation was successful in all patients. Fluoroscopy time and radiation dose in the fluoroscopy group were 11.2 ± 9.0 min and 20.3 ± 16.2Gycm2, whereas no fluoroscopy was used in the opposite group (p < 0.001, respectively). EPS duration was not different between the groups (zero-fluoroscopy:101.6 ± 40.2 min, fluoroscopy:99.4 ± 37.2 min, p = n.s.). Catheter placement time was significantly shorter in the fluoroscopy group (2.2 ± 1.6 min vs. 12.0 ± 7.5 min, p < 0.05), whereas cryo-application duration (from the first cryo-mapping to the last CA) was significantly shorter in the zero-fluoroscopy group (27.5 ± 37.0 min vs. 38.1 ± 33.9 min, p < 0.05). Mean cryo-mapping and CA applications were numerically lower in the zero-fluoroscopy group (CM:7.5 ± 5.7 vs. 8.8 ± 6.2; CA:3.1 ± 1.7 vs. 3.2 ± 2.0, p = n.s.). No major adverse events occurred in both groups. After 15.0 ± 4.2 months, arrhythmia recurrence was not different between the groups (4.5% vs. 8.0%, p = n.s.). Zero-fluoroscopy ICE-guided EP catheter navigation shows comparable efficacy and safety to fluoroscopic guidance during CA in AVNRT patients. ICE visualization of catheters and endocardial structures within the triangle of Koch shortens the cryo-application duration, though time needed for catheter placement is longer, when compared with conventional fluoroscopic guidance, which results in similar mean EPS duration with both navigation techniques. (German Clinical Trials Register ID: DRKS00011360 ; Registration Date 14.12.2016)

16 February 2023 in Fluids
Verified
Journal Article
Open access
PDF file
JKJana Korte
Jana Korte
TRThomas P Rauwolf
Thomas P Rauwolf
JTJan-Niklas Thiel
Jan-Niklas Thiel
AMAndreas Mitrasch
Andreas Mitrasch
PGPaulina Groschopp
Paulina Groschopp
PBPhilipp Berg
Philipp Berg
Purpose: The analysis of pathological human left ventricular hemodynamics using high-resolved image-based blood flow simulations shows a major potential for examining mitral valve insufficiency (MI) under exercise conditions. Since capturing and simulating the patient-specific movement of the left ventricle (LV) during rest and exercise is challenging, this study aims to propose a workflow to analyze the hemodynamics within the pathologically moving LV. Methods: Patient-specific ultrasound (US) data of ten patients with MI in different stages were captured with three-dimensional real-time echocardiography. US measurements were performed while patients were resting and while doing handgrip exercise (2–4 min work). Patient-specific hemodynamic simulations were carried out based on the captured ventricular wall movement. Velocity and kinetic energy were analyzed for rest and exercise and for the different MI stages. Results: The results reveal a dependency of the kinetic energy over time in the ventricular volume curves. Concerning the comparison between rest and exercise, the left ventricular function reveals lower systolic kinetic energy under exercise (kinetic energy normalized by EDV; mean ± standard deviation: rest = 0.16 ± 0.14; exercise = 0.06 ± 0.05; p-value = 0.04). Comparing patients with non-limiting (MI I) and mild/moderate (MI II/III) MI, lower velocities (mean ± standard deviation: non-limiting = 0.10 ± 0.03; mild/moderate = 0.06 ± 0.02; p-value = 0.01) and lower diastolic kinetic energy (kinetic energy normalized by EDV; mean ± standard deviation: non-limiting = 0.45 ± 0.30; mild/moderate = 0.20 ± 0.19; p-value = 0.03) were found for the latter. Conclusion: With the proposed workflow, the hemodynamics within LVs with MI can be analyzed under rest and exercise. The results reveal the importance of the patient-specific wall movement when analyzing intraventricular hemodynamics. These findings can be further used within patient-specific simulations, based on varying the imaging and segmentation methods.