We present a comprehensive investigation into magnetoelastic sensors (MES) technology applied to biomedical engineering. This includes the working principles, detection methods, and application fields of MES technology. MES are made of amorphous metallic glass ribbons and are wireless and passive, meaning that it is convenient to monitor or measure the parameters related to biomedical engineering. MES are based on the inverse magnetoelastic (Villari) effect. When MES are subjected to mechanical stress, their magnetic susceptibility will change accordingly. And the susceptibility of MES is directly related to their magnetic permeability. The varying permeability can positively reflect the applied stress. The various detection methods that have been developed for different field applications include measurement of force, stress, and strain, monitoring of various chemical indexes, and consideration of different biomedical parameters such as the degradation rate and force conditions of artificial bone, as well as various physiological indexes including ammonia level, glucose concentration, bacteria growth, and blood coagulation.
This paper reports on a sensor for monitoring bone plate strain in real time. The detected bone plate strain could be used for judging the healing state of fractures in patients. The sensor consists of a magnetoelastic material, which can be wirelessly connected and passively embedded. In order to verify the effectiveness of the sensor, a tibia-bone plate-screw (TBS) model was established using the finite element analysis method. A variation of the bone plate strain was obtained via this model. A goat hindquarter tibia was selected as the bone fracture model in the experiment. The tibia was fixed on a high precision load platform and an external force was applied. Bone plate strain variation during the bone fracture healing process was acquired with sensing coils. Simulation results indicated that bone plate strain decreases as the bone gradually heals, which is consistent with the finite element analysis results. This validated the soundness of the sensor reported here. This sensor has wireless connections, no in vivo battery requirement, and long-term embedding. These results can be used not only for clinical practices of bone fracture healing, but also for bone fracture treatment and rehabilitation equipment design.
The conventional magnetostrictive strain sensor suffers from low detection sensitivity. In this study, a wireless and passive magnetostrictive strain sensor with improved sensitivity was proposed, modelled, analyzed, and tested. A hollow plate with a negative Poisson’s ratio structure was taken as the substrate, substituting this for the conventional positive Poisson’s ratio material. An analysis model was established for the negative Poisson’s ratio substrate. Finite element method (FEM) analysis was conducted to verify the negative Poisson’s ratio model. Experiments were carried out to prove the sensitivity enhancement principle. Parametric studies were conducted to investigate the influence of the geometry dimension on the output of the electric signal. We show that the proposed sensor has an improved strain test sensitivity of up to 176.3%. The experimental results further indicate that different geometry dimensions of the negative Poisson’s ratio have different influences on the sensitivity of the magnetostrictive strain sensor. The proposed magnetostrictive strain sensor shows the advantages of high sensitivity, easy implementation, convenient fabrication, and low cost.
A novel magnetoelastic-based sensor (MBS) is proposed in this paper to monitor the force of artificial bone (AB) using magnetoelastic material as the sensing element based on the inverse magnetoelastic effect. The MBS is embedded inside the AB using novel 3D printing technology (N3DPT). Seven ABs are fabricated by N3DPT and tested by self-developed experimental devices to select the optimum output position of MBS and explore the relationship between the external force working on the AB and the varying value of output power (VOP) caused by the MBS. The applied force of the AB covered by biological tissue is also further monitored using MBS. Results indicate that the middle position (h=0) of the AB can fully express the performance of MBS and clearly reflect and monitor the applied force of the AB using a wireless and passive method. An increase of external force working on the AB can cause a rise in output power of the sensing coil which is 0.5 dbm of the VOP under 100 N external force. This further demonstrates that the MBS can efficiently monitor the force of AB and prosthesis in vitro and in vivo.
A new two-dimensional wireless and passive stress sensor using the inverse magnetostrictive effect is proposed, designed, analyzed, fabricated, and tested in this work. Three pieces of magnetostrictive material are bonded on the surface of a smart elastomer structure base to form the sensor. Using the external load, an amplitude change in the higher-order harmonic signal of the magnetic material is detected (as a result of the passive variation of the magnetic permeability wirelessly). The finite element method (FEM) is used to accomplish the design and analysis process. The strain-sensitive regions of the tension and torque are distributed at different locations, following the FEM analysis. After the fabrication of a sensor prototype, the mechanical output performance is measured. The effective measurement range is 0–40 N and 0–4 N·M under tension and torque, respectively. Finally, the error of the sensor after calibration and decoupling for Fx is 3.4% and for Tx is 4.2% under a compound test load (35 N and 3.5 N·M). The proposed sensor exhibits the merits of being passive and wireless, and has an ingenious structure. This passive and wireless sensor is useful for the long-term detection of mechanical loading within a moving object, and can even potentially be used for tracing dangerous overloads and for preventing implant failures by monitoring the deformation of implants in the human body.