Kun Yu

Kun Yu

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
LRLimin Ren
Limin Ren
KYKun Yu
Kun Yu
YTYisong Tan
Yisong Tan
We present a comprehensive investigation into magnetoelastic sensors (MES) technology applied to biomedical engineering. This includes the working principles, detection methods, and application fields of MES technology. MES are made of amorphous metallic glass ribbons and are wireless and passive, meaning that it is convenient to monitor or measure the parameters related to biomedical engineering. MES are based on the inverse magnetoelastic (Villari) effect. When MES are subjected to mechanical stress, their magnetic susceptibility will change accordingly. And the susceptibility of MES is directly related to their magnetic permeability. The varying permeability can positively reflect the applied stress. The various detection methods that have been developed for different field applications include measurement of force, stress, and strain, monitoring of various chemical indexes, and consideration of different biomedical parameters such as the degradation rate and force conditions of artificial bone, as well as various physiological indexes including ammonia level, glucose concentration, bacteria growth, and blood coagulation.

4 November 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LRLimin Ren
Limin Ren
MCMoyue Cong
Moyue Cong
YFYifu Fu
Yifu Fu
KYKun Yu
Kun Yu
YTYisong Tan
Yisong Tan
The conventional magnetostrictive strain sensor suffers from low detection sensitivity. In this study, a wireless and passive magnetostrictive strain sensor with improved sensitivity was proposed, modelled, analyzed, and tested. A hollow plate with a negative Poisson’s ratio structure was taken as the substrate, substituting this for the conventional positive Poisson’s ratio material. An analysis model was established for the negative Poisson’s ratio substrate. Finite element method (FEM) analysis was conducted to verify the negative Poisson’s ratio model. Experiments were carried out to prove the sensitivity enhancement principle. Parametric studies were conducted to investigate the influence of the geometry dimension on the output of the electric signal. We show that the proposed sensor has an improved strain test sensitivity of up to 176.3%. The experimental results further indicate that different geometry dimensions of the negative Poisson’s ratio have different influences on the sensitivity of the magnetostrictive strain sensor. The proposed magnetostrictive strain sensor shows the advantages of high sensitivity, easy implementation, convenient fabrication, and low cost.

9 October 2018 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LRLimin Ren
Limin Ren
KYKun Yu
Kun Yu
YTYisong Tan
Yisong Tan
A novel magnetoelastic-based sensor (MBS) is proposed in this paper to monitor the force of artificial bone (AB) using magnetoelastic material as the sensing element based on the inverse magnetoelastic effect. The MBS is embedded inside the AB using novel 3D printing technology (N3DPT). Seven ABs are fabricated by N3DPT and tested by self-developed experimental devices to select the optimum output position of MBS and explore the relationship between the external force working on the AB and the varying value of output power (VOP) caused by the MBS. The applied force of the AB covered by biological tissue is also further monitored using MBS. Results indicate that the middle position (h=0) of the AB can fully express the performance of MBS and clearly reflect and monitor the applied force of the AB using a wireless and passive method. An increase of external force working on the AB can cause a rise in output power of the sensing coil which is 0.5 dbm of the VOP under 100 N external force. This further demonstrates that the MBS can efficiently monitor the force of AB and prosthesis in vitro and in vivo.

1 May 2013 in Materials Letters
Verified
Journal Article
Closed access
KYKun Yu
Kun Yu
CJChen Liang Jian
Chen Liang Jian
JZJun Zhao
Jun Zhao
RWRuifang Wang
Ruifang Wang
YDYilong Dai
Yilong Dai
QHQiao Huang
Qiao Huang

18 February 2019 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
DJDayue Jiang
Dayue Jiang
YDYilong Dai
Yilong Dai
YZYu Zhang
Yu Zhang
CLCongcong Liu
Congcong Liu
KYKun Yu
Kun Yu
Mg-1Zn-1Mn (wt. %) alloy and Mg-1Zn-1Mn-xSr (wt. %, x=0.1, 0.25, 0.5, 1) alloy as candidates for degradable biomaterials were prepared by casting and extrusion methods. The effect of Sr addition on microstructure, mechanical properties, corrosion resistance and cytotoxicity of Mg-Zn-Mn alloy was investigated. The results showed that Mg-1Zn-1Mn alloy mainly consisted of α-Mg matrix phase while Mg11Zn4Sr3 phase was formed in Mg-1Zn-1Mn-0.25Sr, Mg-1Zn-1Mn-0.5Sr and Mg-1Zn-1Mn-1Sr alloy. After adding Sr, the highest tensile strength of Mg-1Zn-1Mn-1Sr alloy was 280MPa, but its elongation dropped to 7%. Mg-1Zn-1Mn-0.25Sr alloy exhibited better corrosion resistance in immersion tests, with hydrogen evolution rate of 0.42mm/year, weight loss rate of 0.72mm/year, and pH value of 9.0. The cytotoxicity tests indicated that both Mg-1Zn-1Mn and Mg-1Zn-1Mn-0.25Sr alloys were non-toxic against L-929 cells and the highest relative growth rate of Mg-Zn-Mn-0.25Sr extracts group was 102%.

12 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
LRLimin Ren
Limin Ren
KYKun Yu
Kun Yu
YTYisong Tan
Yisong Tan
A magnetoelastic-based (MB) sensor was employed as a novel method to monitor and assess the degradation rate of magnesium-based artificial bone (MBAB) in vitro, which can be used as an implant to repair a bone defect, providing a quantitative method to depict the degradation rate of MBAB. MBABs were fabricated by the Pro/Engineering software and a precision machine tool using high-purity (HP) magnesium. The MB sensor was embedded in the neutral surface of MBAB by an unharmful quick adhesive, forming the MB sensor-embedded MBAB (EMBAB). The modified simulated body fluid (MSBF) media (PH = 7.4), mimicking the human internal environment, and the NaOH media (PH = 12), accelerating EMBAB’s degradation, were used to immerse the EMBAB for 15 days at 37 °C. The EMBAB was then tested daily on a self-developed experimental platform to monitor the relative output power under a 100 N external force. The results showed that the relative output power of the sensing coil gradually increased with the EMBAB’s degradation. The degradation rate of the EMBAB could be calculated on the basis of the changes of the relative output power caused by the MB sensor and of the degradation time. With the EMBAB’s degradation, an increasing strain directly worked on the MB sensor, significantly changing the value of the relative output power, which means that the EMBAB was characterized by a quick degradation rate. During the 15 days of the experiment, the degradation rates on the 7th and 15th days were 0.005 dbm/day and 0.02 dbm/day, and 0.02 dbm/day and 0.04 dbm/day in MSBF and alkaline media, respectively. Therefore, the MB sensor provides a wireless and passive method to monitor and assess the degradation rate of bone implants in vitro.