Semiconductor power devices are vulnerable to failures, which challenge the reliability of power conversion systems. One of the most effective methods to enhance system reliability is fault-tolerant techniques. Presently, the parallel redundant converter approach is considered as one of the most effective fault-tolerant method. However, there are some issues regarding parallel converter systems, such as surge currents that non-faulty converters experience after faults, fault isolation time and load voltage distortion. To address these issues, this paper investigates the fault analysis and fault-tolerant design regarding parallel inverter systems. The stage analysis for the parallel inverter systems in case of IGBT short-circuit failures is analyzed first. Then, the surge current and corresponding fault isolation duration are explored. Furthermore, a mathematical model is built to address these two issues and a fault-tolerant design to suppress surge current is presented. Finally, the experimental results are provided.
Field experiences have demonstrated that semiconductor devices are vulnerable to failures (open-& short-circuit). In many critical applications, such failures are unacceptable and high system reliability is required. In this paper, a topology modification for the T-type 3-level inverter is explored to achieve the fault-tolerant operation and enhance the system reliability in the case of device open-circuit or short-circuit failures. With the proposed topology modification (via fewer additional switches), the device failure ride-through performance can be dynamically achieved without degradation of output capacity. Furthermore, the transition principles from normal operations to post-fault operations are detailed, and the reliability enhancement is calculated. The simulation results are included to verify the validity of the modified topology.
It is simple to implement conventional current control with a proportional integral (PI) controller. However, system stability and dynamic performance are not perfect, particularly when operating under unfavorable conditions. In this paper, an improved control method is proposed by introducing a compensation unit. The compensation unit can effectively compensate the system’s phase around the crossover frequency, greatly enhancing the system’s phase margin and stability. It is also capable of handling weak-grid conditions. In this paper, the concept of the proposed compensation unit is explained first. Then, the corresponding mathematical model for the current control loop is built, and system bode diagrams for the conventional and proposed methods are compared. Furthermore, the effect of the parameters for the compensation unit is investigated, and an optimization method is proposed to determine optimal parameters. In addition, to handle weak-grid conditions, the proposed scheme is expanded by including the compensation unit in the grid’s feed-forward loop. Finally, an experimental platform is constructed, and the experimental results are presented to validate the proposed method.
24 July 2015 in The Open Fuels & Energy Science Journal
The purpose of this study is to improve the cementing quality of shale gas well by mud cake solidification, as well as to provide the better annular isolation for its hydraulic fracturing development. Based on the self-established experimental method and API RP 10, the effects of mud cake solidifiers on the shear strength at cement-interlayer interface (SSCFI) were evaluated. After curing for 3, 7, 15 and 30 days, SSCFI was remarkably improved by 629.03%, 222.37%, 241.43% and 273.33%, respectively, compared with the original technology. Moreover, the compatibility among the mud cake solidifier, cement slurry, drilling fluid and prepad fluid meets the safety requirements for cementing operation. An application example in a shale gas well (Yuanye HF-1) was also presented. The high quality ratio of cementing quality is 93.49% of the whole well section, while the unqualified ratio of adjacent well (Yuanba 9) is 84.46%. Moreover, the cementing quality of six gas-bearing reservoirs is high. This paper also discussed the mechanism of mud cake solidification. The reactions among H3AlO42- and H3SiO4- from alkali-dissolved reaction, Na+ and H3SiO4- in the mud cake solidifiers, and Ca2+ and OH- from cement slurry form the natrolite and calcium silicate hydrate (C-S-H) with different silicate-calcium ratio. Based on these, SSCFI and cementing quality were improved.
The use of electric vehicles (EVs) for household uninterruptible power supplies (UPSs), particularly in rural areas, can greatly improve household power reliability. However, because EVs are mobile, the evaluation of backup capacity for EV-UPS systems is completely different when compared to traditional UPSs. As a result, the focus of this paper is on the evaluation and improvement of backup capacity for EV-UPS systems. The architectures for EV-UPS systems are presented first. The methodology for calculating backup capacity for EV-UPS systems is then presented, followed by four detailed cases based on different grid failure times. Furthermore, the impact of system operating parameters on backup capacity, such as different load power, EV mobility pattern parameters, and grid outage durations, is investigated. The results of backup capacity in cases of different operating parameters are detailed using an EV mobility model. An improved strategy for increasing backup capacity is proposed, in which more backup energy can be released during a power outage. Meanwhile, the next trip requirement is unaffected. The backup capacity with the improved strategy is then calculated and compared to the results with the traditional strategy. Finally, a 5 kW EV-UPS experimental platform is constructed, and the experimental results are presented to validate the proposed method.