22 May 2018 in IEEE Transactions on Power Electronics
This paper proposes a local power-based droop controller for distributed energy resource converters in dc microgrids that are connected to upstream grids by grid-interface converters. During normal operation, the grid-interface converter imposes the microgrid bus voltage and the proposed controller allows power flow regulation at distributed energy resource converters output. On the other hand, during abnormal operation of the grid-interface converter (e.g., due to faults in the upstream grid), the proposed controller allows bus voltage regulation by droop control. Notably, the controller can autonomously convert from power flow control to droop control, without any need of bus voltage variations detection schemes or communication with other microgrid components, which enables seamless transitions between these two modes of operation. Considering distributed energy resource converters employing the power-based droop control, the operation modes of a single converter and of the whole microgrid are defined and investigated herein. The controller design is also introduced. Furthermore, the power sharing performance of this control approach is analyzed and compared with that of classical droop control. The experimental results from a laboratory-scale dc microgrid prototype are reported to show the final performances of the proposed power-based droop control.
5 February 2019 in IEEE Transactions on Industrial Electronics
Droop-controlled distributed energy resource converters in dc microgrids usually show low output impedances. When coupled with ac systems, second-order harmonics typically appear on the dc-bus voltage, causing significant harmonic currents at the converters resource side. In this paper, we show how to reduce such undesired currents by means of notch filters and resonant regulators included in the converters control loops. The main characteristics of these techniques in terms of harmonic attenuation and stability are systematically investigated. In particular, it is shown that the voltage control-loop bandwidth is limited to be below twice the line frequency to avoid instability. Then, a modified notch filter and a modified resonant regulator are proposed, allowing to remove the constraint on the voltage loop bandwidth. The resulting methods (i.e., the notch filter, the resonant regulator, and their corresponding modified versions) are evaluated in terms of output impedance and stability. Experimental results from a dc microgrid prototype composed of three dc-dc converters and one dc-ac converter, all with a rated power of 5 kW, are reported.
6 November 2019 in IEEE Transactions on Power Electronics
In dc microgrids, droop control is widely employed in power converters interfacing distributed energy resources and common dc bus for automatic power sharing. In order to limit the dc bus voltage variations even during the load transient conditions, it is necessary to shape the output impedance of droop-controlled converters to be always lower than the dc resistive value. A commonly used way is to install bulky output capacitance, which not only increases the system cost, size and weight, but also generates higher short-circuit fault currents. In order to avoid large output capacitance, this paper proposes a design approach for droop-controlled converters, including the selection criterion of the output capacitance and the design of the droop coefficient. Herein, the required output capacitance is calculated based on the dc droop coefficient and the voltage control bandwidth. The droop coefficient is designed as a frequency-dependent term instead of a constant value. As a result, the desired output impedance can be obtained with a much smaller output capacitance. The proposed design strategy is applied to buck and boost converters and validated by experimental results performed on a buck-based and a boost-based dc microgrid prototype, respectively.
23 July 2018 in IEEE Transactions on Power Electronics
An on-line approach to evaluate and monitor the stability margins of dc microgrid power converters is presented in this paper. The discussed online stability monitoring technique (MT) is based on the Middlebrook's loop-gain measurement technique, adapted to the digitally controlled power converters. In this approach, a perturbation is injected into a specific digital control loop of the converter and after measuring the loop gain, its crossover frequency and phase margin are continuously evaluated and monitored. The complete analytical derivation of the model, as well as detailed design aspects, are reported. In addition, the presence of multiple power converters connected to the same dc bus, all having the stability monitoring unit, is also investigated. An experimental microgrid prototype is implemented and considered to validate the theoretical analysis and simulation results, and to evaluate the effectiveness of the digital implementation of the technique for different control loops. The obtained results confirm the expected performance of the stability monitoring tool in steady-state and transient operating conditions. The proposed method can be extended to generic control loops in power converters operating in dc microgrids.
12 December 2019 in IEEE Transactions on Industrial Electronics
Power electronic converters used in a dc microgrid environment are usually equipped with several control loops. When many converters are connected to a common dc bus, the performance of some loops can be different from the behavior designed for the stand-alone converter, depending on the number, topology, and control of the interconnected converters. In order to establish the performance of each loop in real-time, it is important to continuously monitor the loop gains. This article presents the application of an online identification technique in rapid and simultaneous measurement of several control loops in dc microgrid power converters. To this end, multiple orthogonal pseudorandom binary sequences (PRBSs) are simultaneously injected into different loops of power converters. Since the frequency components excited by each PRBS are unique and different from any other, multiple PRBSs can be injected at the same time. This will allow to measure all the loop gains in only one measurement cycle. Hence, the operating condition of the system is kept unchanged during the measurement, which is an important factor to achieve accurate monitoring. The online identification method is applied to an experimental dc microgrid prototype, composed of three droop-controlled converters. After identifying different control loops, an adaptive tuning algorithm is implemented to adjust the digital compensator of each loop, in order to reach the desired dynamic performance. The reported experimental results confirm the accuracy and the applicability of this technique.