Makis Livadas

Dr. Makis Livadas


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2016 in Sensors
Verified
Journal Article
Open access
PDF file
MKMaria Kogia
Maria Kogia
Tat-Hean GanTat-Hean Gan
Tat-Hean Gan
WBWamadeva Balachandran
Wamadeva Balachandran
MLMakis Livadas
Makis Livadas
Vassilios KappatosVassilios Kappatos
Vassilios Kappatos
ARAndrew Round
Andrew Round
Guided Wave Testing (GWT) using novel Electromagnetic Acoustic Transducers (EMATs) is proposed for the inspection of large structures operating at high temperatures. To date, high temperature EMATs have been developed only for thickness measurements and they are not suitable for GWT. A pair of water-cooled EMATs capable of exciting and receiving Shear Horizontal (SH0) waves for GWT with optimal high temperature properties (up to 500 °C) has been developed. Thermal and Computational Fluid Dynamic (CFD) simulations of the EMAT design have been performed and experimentally validated. The optimal thermal EMAT design, material selection and operating conditions were calculated. The EMAT was successfully tested regarding its thermal and GWT performance from ambient temperature to 500 °C.

15 March 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSMohamad Salimi
Mohamad Salimi
MLMakis Livadas
Makis Livadas
ATAhmed Teyeb
Ahmed Teyeb
EMEvelyne El Masri
Evelyne El Masri
Tat-Hean GanTat-Hean Gan
Tat-Hean Gan
This paper explains producing a novel ultrasonic system to remove/prevent biofouling growth from wind turbines’ access ladders by means of producing local ultrasound cavitation. Using bespoke hardware, an array of high-power ultrasound transducers (HPUTS) and optimally synthesized signal types to remove/prevent biofouling growth from the ladder without violating the standard noise level in the sea is explained. This is a non-toxic and non-invasive solution to detach biofouling and prevent biofilm initiation on offshore structures. It is shown that the marinisation of the HPUT slightly shifts the main resonance frequency from 28.1 to 27.5 kHz. The vibration output from the HPUTs with different mounting systems showed that the transducer with the horn could vibrate the plate at 20 cm from the excitation point, with 300 pm, six times higher than the vibration output from the marinised HPUT. A transducer array and attachment are proposed to make the ultrasound noise below the standard underwater noise limits. The produced sound pressure level (SPL) and sound equivalent level (SEL) from the proposed ultrasonic system was measured. It was specified that the SPL came below 120 dB at 25 m from the excitation point and the SEL value below the 173 dB limit. Finally, the effectiveness of the marinised HPUTS on biofouling removal has been demonstrated with an in-situ measurement, and it was indicated that local biofouling removal could be achieved.