Wentong Qiao

Mr. Wentong Qiao

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2023 in Aerospace
Verified
Journal Article
Open access
PDF file
XZXiaoguang Zhang
Xiaoguang Zhang
WQWentong Qiao
Wentong Qiao
QGQixiang Gao
Qixiang Gao
DZDingwei Zhang
Dingwei Zhang
LYLijun Yang
Lijun Yang
Qingfei FuQingfei Fu
Qingfei Fu
To determine the dynamic characteristics of a gas-centered swirl coaxial injector under backpressure, an experimental system of dynamic injection in a backpressure chamber was constructed. Filtered water and nitrogen were used as simulant media for rocket propellants, which are typically used with this kind of injector. An inertial flow pulsator was manufactured to generate the pulsation of the flows that feed to the liquid injector. The electric conductance method was adopted to measure liquid film thickness. After the pulsation of incoming flow in the feedline was tested, and the operating conditions for the injector to start pulsating were validated, the effects of the chamber backpressure and the recess length of the injector on the dynamic characteristics of spray, such as liquid film thickness, breakup length, and amplitude of pulsation, have been investigated in detail. Experimental results demonstrated that the increase in chamber backpressure prompts the liquid sheet to rupture earlier with a shorter breakup length, which results from the increased density of the ambient gas. Chamber backpressure suppresses the pulsation of the outlet flow, especially for a longer recess length. Moreover, a decrease in the recess length results in a reduction in breakup length due to an intense gas–liquid shearing in a narrower recess section. For a lower backpressure, the amplitude of outlet flow generally increases when the recess length increases. However, this phenomenon is not obvious for the conditions of higher backpressure and lower pulsation frequency.

23 May 2024 in Acta Astronautica
Verified
Journal Article
Closed access
ZFZixuan Fang
Zixuan Fang
WQWentong Qiao
Wentong Qiao
CMCaoxing Mo
Caoxing Mo
Jingxuan LiJingxuan Li
Jingxuan Li
LYLijun Yang
Lijun Yang
Qingfei FuQingfei Fu
Qingfei Fu

29 November 2023 in Acta Astronautica
Verified
Journal Article
Closed access
SWShaoyan Wang
Shaoyan Wang
WQWentong Qiao
Wentong Qiao
DZDingwei Zhang
Dingwei Zhang
BZBingbing Zhang
Bingbing Zhang
QFQingfei Fu
Qingfei Fu

7 May 2024 in Acta Astronautica
Verified
Journal Article
Closed access
WQWentong Qiao
Wentong Qiao
SWShaoyan Wang
Shaoyan Wang
XYXiaocong Yang
Xiaocong Yang
HWHegu Wan
Hegu Wan
ZDZhi Deng
Zhi Deng
Qingfei FuQingfei Fu
Qingfei Fu

15 March 2024 in International Journal of Aerospace Engineering
Verified
Journal Article
Open access
PDF file
WQWentong Qiao
Wentong Qiao
CLChengkai Liang
Chengkai Liang
LLLuhao Liu
Luhao Liu
SWShaoyan Wang
Shaoyan Wang
BZBingbing Zhang
Bingbing Zhang
Qingfei FuQingfei Fu
Qingfei Fu
To investigate the self-pulsation characteristics of a liquid-centered swirl coaxial injector with liquid oxygen (LOX) and gas hydrogen (GH2) as the working mediums under supercritical condition, a numerical simulation was employed. The transient simulation of the flow and injection process of cryogenic propellant was carried out using the RNG turbulence model, VOF model, and Peng-Robinson equation of state. The frequency spectrum of calculated pressure oscillation agreed with the experimental data. The amplitude-frequency characteristics of recess region, LOX, and GH2 paths when self-pulsation occurs were analyzed. The effects of operating parameters, such as the flow rate of LOX or GH2 and the initial GH2 temperature, on the self-pulsation, were evaluated specifically. Results reveal that the self-pulsation results from the periodic variation of pressure and velocity caused by the periodic blocking of annular gas by the liquid sheet. The dominant frequencies of pressure oscillation in the recess region, upstream of LOX, or GH2 path are diverse. But for the points in each region, the dominant frequency is about the same. When the LOX/GH2 mixing ratio increases, the liquid sheet thickness and the number of liquid filaments increase. The position where filaments are massively broken into droplets moves further downstream. For the same mixing ratio, the flow rate of LOX has a greater impact on the atomization features. The pressures corresponding to low or high frequency increase when the initial GH2 temperature raises. The higher temperature would shift the dominant oscillation between the low and high regimes.

12 May 2022 in Advances in Mechanical Engineering
Verified
Journal Article
Open access
WQWentong Qiao
Wentong Qiao
LQLijuan Qian
Lijuan Qian
CZChenlin Zhu
Chenlin Zhu
JLJingqi Liu
Jingqi Liu
Uneven coatings with overspray often occur to the target plate when using a pneumatic atomizer. This issue is mainly due to the high-level pressure in the plate center, which results from unreasonable design of the structure and operating parameters in atomizer. In this paper, an optimal design for these parameters was established by response surface method (RSM) and computational fluid dynamics (CFD) to produce more uniform coatings. The velocity data measured by a hot-wire anemometry experimentally verified the numerical model. Then, annular air hole diameter, horn flare angle, annular air pressure, and shaping air pressure were selected as design variables while the central pressure was chosen as objective function. The RSM with the central composite design (CCD) was employed to construct the regression equation that expresses the relationship between the central pressure and design parameters. Finally, the optimum combination of the parameters was carried out for reducing the central pressure, and the interaction effects between the parameters were also analyzed. The optimization results show that the central pressure is decreased by 44.6% and the performance of droplet size distribution is significantly improved. The experiment confirmed the effectiveness of the optimized atomizer to obtain well-distributed coatings.