Ali Ashraf

Dr. Ali Ashraf

College of Engineering and Computer Science, The University of Texas Rio Grande Valley, Edinburg, TX, USA
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Nano Letters
Verified
Journal Article
Closed access
AAAli Ashraf
Ali Ashraf
YWYanbin Wu
Yanbin Wu
MWMichael Cai Wang
Michael Cai Wang
KYKeong Yong
Keong Yong
TSTao Sun
Tao Sun
Sungwoo NamSungwoo Nam
Sungwoo Nam

10 February 2015 in Nano Letters
Verified
Journal Article
Closed access
MWMichael Cai Wang
Michael Cai Wang
SCSungGyu Chun
SungGyu Chun
RHRyan Steven Han
Ryan Steven Han
AAAli Ashraf
Ali Ashraf
PKPilgyu Kang
Pilgyu Kang
Sungwoo NamSungwoo Nam
Sungwoo Nam

23 October 2014 in Langmuir
Verified
Journal Article
Closed access
AAAli Ashraf
Ali Ashraf
YWYanbin Wu
Yanbin Wu
MWMichael Cai Wang
Michael Cai Wang
NANarayana R. Aluru
Narayana R. Aluru
SDSeyed Dastgheib
Seyed Dastgheib
Sungwoo NamSungwoo Nam
Sungwoo Nam

10 February 2017 in Nano Letters
Verified
Journal Article
Closed access
JCJonghyun Choi
Jonghyun Choi
JMJihun Mun
Jihun Mun
MWMichael Cai Wang
Michael Cai Wang
AAAli Ashraf
Ali Ashraf
SKSang-Woo Kang
Sang-Woo Kang
Sungwoo NamSungwoo Nam
Sungwoo Nam

27 April 2016 in Scientific Reports
Verified
Journal Article
Open access
KYKeong Yong
Keong Yong
AAAli Ashraf
Ali Ashraf
PKPilgyu Kang
Pilgyu Kang
Sungwoo NamSungwoo Nam
Sungwoo Nam
We report a one-step polymer-free approach to patterning graphene using a stencil mask and oxygen plasma reactive-ion etching, with a subsequent polymer-free direct transfer for flexible graphene devices. Our stencil mask is fabricated via a subtractive, laser cutting manufacturing technique, followed by lamination of stencil mask onto graphene grown on Cu foil for patterning. Subsequently, micro-sized graphene features of various shapes are patterned via reactive-ion etching. The integrity of our graphene after patterning is confirmed by Raman spectroscopy. We further demonstrate the rapid prototyping capability of a stretchable, crumpled graphene strain sensor and patterned graphene condensation channels for potential applications in sensing and heat transfer, respectively. We further demonstrate that the polymer-free approach for both patterning and transfer to flexible substrates allows the realization of cleaner graphene features as confirmed by water contact angle measurements. We believe that our new method promotes rapid, facile fabrication of cleaner graphene devices and can be extended to other two dimensional materials in the future.

27 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MRMd Ashiqur Rahman
Md Ashiqur Rahman
RPRamendra Kishor Pal
Ramendra Kishor Pal
Nazmul IslamNazmul Islam
Nazmul Islam
RFRobert Freeman
Robert Freeman
FBFrancois Berthiaume
Francois Berthiaume
AAAli Ashraf
Ali Ashraf
Paper-based biosensors are a potential paradigm of sensitivity achieved via microporous spreading/microfluidics, simplicity, and affordability. In this paper, we develop decorated paper with graphene and conductive polymer (herein referred to as graphene conductive polymer paper-based sensor or GCPPS) for sensitive detection of biomolecules. Planetary mixing resulted in uniformly dispersed graphene and conductive polymer ink, which was applied to laser-cut Whatman filter paper substrates. Scanning electron microscopy and Raman spectroscopy showed strong attachment of conductive polymer-functionalized graphene to cellulose fibers. The GCPPS detected dopamine and cytokines, such as tumor necrosis factor-alpha (TNF-α), and interleukin 6 (IL-6) in the ranges of 12.5–400 µM, 0.005–50 ng/mL, and 2 pg/mL–2 µg/mL, respectively, using a minute sample volume of 2 µL. The electrodes showed lower detection limits (LODs) of 3.4 µM, 5.97 pg/mL, and 9.55 pg/mL for dopamine, TNF-α, and IL-6 respectively, which are promising for rapid and easy analysis for biomarkers detection. Additionally, these paper-based biosensors were highly selective (no serpin A1 detection with IL-6 antibody) and were able to detect IL-6 antigen in human serum with high sensitivity and hence, the portable, adaptable, point-of-care, quick, minute sample requirement offered by our fabricated biosensor is advantageous to healthcare applications.