20 September 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
EKEpameinondas Kontos
Epameinondas Kontos
TSTim Schultz
Tim Schultz
LMLaurens Mackay
Laurens Mackay
LRLaura M. Ramirez-Elizondo
Laura M. Ramirez-Elizondo
CFChristian M. Franck
Christian M. Franck
Pavol BauerPavol Bauer
Pavol Bauer
This paper presents a breaker arrangement concept, the multiline breaker (MLB), for the protection of multiterminal high voltage dc (MTdc) networks. Based on the design of a hybrid breaker, the MLB is an economically attractive solution for the protection of multiple dc lines in nodal connection using a single main breaker path. By using commutation units, the MLB directs the fault current through the main breaker in a unidirectional way, irrespective of the fault location. Hence, this study presents the design requirements for the MLB, regarding both hardware and control, and evaluates its operation within a grid. For this reason, a four-terminal half-bridge multilevel modular converters-based MTdc grid in radial configuration was used and pole-to-ground dc fault conditions were investigated. The dc fault response of the grid with one MLB at the central node is compared to the respective response of the grid when one hybrid breaker is employed at each dc line. The simulations show that the MLB is feasible and that the overall MTdc grid fault response for the two protection systems is very similar. As a result, the design advantages of the MLB make it a promising solution for the dc fault isolation in MTdc grids.

4 September 2017 in IEEE Access
Verified
Journal Article
Open access
EKEpameinondas Kontos
Epameinondas Kontos
GTGeorgios Tsolaridis
Georgios Tsolaridis
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Pavol BauerPavol Bauer
Pavol Bauer
Due to the increase of power electronic-based loads, the maintenance of high power quality poses a challenge in modern power systems. To limit the total harmonic distortion in the line voltage and currents at the point of the common coupling (PCC), active power filters are commonly employed. This paper investigates the use of the multilevel modular converter (MMC) for harmonics mitigation due to its high bandwidth compared with conventional converters. A selective harmonics detection method and a harmonics controller are implemented, while the output current controller of the MMC is tuned to selectively inject the necessary harmonic currents. Unlike previous studies, focus is laid on the experimental verification of the active filtering capability of the MMC. For this reason an MMC-based double-star STATCOM is developed and tested for two representative case studies, i.e., for grid currents and PCC voltage harmonics. The results verify the capability of the MMC to mitigate harmonics up to the thirteenth order, while maintaining a low effective switching frequency and thus, low switching losses.

18 October 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
EKEpameinondas Kontos
Epameinondas Kontos
GTGeorgios Tsolaridis
Georgios Tsolaridis
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Pavol BauerPavol Bauer
Pavol Bauer
This paper studies the dc fault development stages and analyzes the fault dynamics in a point-to-point multilevel modular converters (MMC)-based dc connection. First, the effect of the dc grid configuration on the normal operation was investigated by comparing an asymmetric monopole with metallic return and a symmetric monopole. Then, the main parameters that affect the dc fault response of a grid, such as the fault type, impedance and converter blocking, were examined. Compared to previous studies, which are based on simulation results, the analysis is performed hereby both in theory, deriving the equations that describe the dc fault stages, as well as using experimental results obtained in the designed laboratory setup. The setup consists of two MMC terminals connected to two ac sources representing independent ac grids. These terminals are connected using a simple dc link based on pi-section equivalent of dc cables. The obtained results, which verified the theoretical analysis, can be used to determine the protection function thresholds of the MMC, as well as to estimate the developed stresses on dc lines during fault conditions and to define the design requirements for dc breakers.

1 October 2017 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
EKEpameinondas Kontos
Epameinondas Kontos
GTG. Tsolaridis
G. Tsolaridis
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
PBP. Bauer
P. Bauer
This paper investigates a control structure to enhance the DC fault ride-through capability of a full-bridge modular multilevel converter (MMC) station, while ensuring a stable controlled operation as a STATCOM during DC faults without the need for fault isolation. Taking advantage of the switching states of a full-bridge submodule, a DC current controller is proposed, which provides the DC voltage reference for the modulation when a DC fault is detected. By changing the outer controllers strategy from DC voltage or active power control to converter energy control during a fault, the decoupling of the converter operation from the DC side dynamics is realized. In this paper, the focus is on the control methodology at all times of operation and the evaluation of the STATCOM control during a fault. To this end, extensive simulations were performed on a three-terminal high voltage direct current (HVDC) grid in radial configuration and a pole-to-pole DC fault case was investigated. The results showed that the AC voltage and current were controlled within limits at all times, while the full-bridge MMC was able to provide reactive power support to the AC grid. Moreover, using the proposed control methodology, the transients at the operation transition points between STATCOM and inverter/rectifier operation were minimized and the stations were able to safely ride through the fault.

1 December 2017
Verified
Conference Paper
Closed access
Aditya ShekharAditya Shekhar
Aditya Shekhar
EKEpameinondas Kontos
Epameinondas Kontos
LRLaura Ramirez-Elizondo
Laura Ramirez-Elizondo
Pavol BauerPavol Bauer
Pavol Bauer
A practical issue faced by today's ac grid is the rapidly growing power demand on its aging infrastructure. One possibility to maximize the capacity of the existing infrastructure is to refurbish the ac links to operate under dc conditions using modular multilevel converters. In this paper, the idea is applied to restructure an actual medium voltage distribution system. Further, a systematic reconfiguration strategy is proposed to maintain high power delivery capacity even during (n-1) contingency. Contingency analysis is carried out for faults in different system components of the distribution grid. Towards this goal, novel concepts such as reconfigurable switch, dc link converter bypass and flexible dc to ac operational transition are proposed.

5 July 2017 in Energies
Verified
Journal Article
Open access
PDF file
GTGeorgios Tsolaridis
Georgios Tsolaridis
EKEpameinondas Kontos
Epameinondas Kontos
Sanjay Kumar ChaudharySanjay Kumar Chaudhary
Sanjay Kumar Chaudhary
Pavol BauerPavol Bauer
Pavol Bauer
Remus TeodorescuRemus Teodorescu
Remus Teodorescu
Grid faults are common in power systems and can have a severe impact on the operation of the converters in the system. In this paper, the operation of a Modular Multilevel Converter (MMC)-based Static Synchronous Compensators (STATCOM) is investigated during grid faults. The study focuses on the challenging internal control of the converter to allow the independent control of the energy levels of each arm, with the goal to maintain internal balancing of the MMC during contingencies. Extensive experimental results highlight the need for a sophisticated internal control. Moreover, the experimental analysis verifies that, by using the proposed control structure, the MMC can effectively ride through a fault on the AC side without tripping, while injecting the necessary positive and negative sequence reactive current levels according to the most recent grid codes.