15 June 2017 in Electric Power Components and Systems
Due to an increasing number of power generation units and load devices operating with direct current (DC) at distribution level, there is a potential benefit of leading efforts toward building a DC distribution system. However, the implementation of DC distribution systems faces important challenges, including the market inertia of AC systems and standardization. Many of the benefits that are attributed to DC can only be realized if a complete DC system is developed, and not if only a few components are replaced. This paper presents the concept of a universal DC distribution system, as envisioned by the authors. The universal DC distribution system could be implemented in various use cases, but could also completely replace AC distribution grids. The paper covers the possibilities of having DC nanogrids inside buildings, DC microgrids in neighborhoods, and the connection to AC and DC medium voltage grids. Furthermore, considerations regarding flexibility, electricity market design, control, and protection are presented
20 September 2017 in IEEE Transactions on Power Delivery
LRLaura M. Ramirez-Elizondo
Laura M. Ramirez-Elizondo
This paper presents a breaker arrangement concept, the multiline breaker (MLB), for the protection of multiterminal high voltage dc (MTdc) networks. Based on the design of a hybrid breaker, the MLB is an economically attractive solution for the protection of multiple dc lines in nodal connection using a single main breaker path. By using commutation units, the MLB directs the fault current through the main breaker in a unidirectional way, irrespective of the fault location. Hence, this study presents the design requirements for the MLB, regarding both hardware and control, and evaluates its operation within a grid. For this reason, a four-terminal half-bridge multilevel modular converters-based MTdc grid in radial configuration was used and pole-to-ground dc fault conditions were investigated. The dc fault response of the grid with one MLB at the central node is compared to the respective response of the grid when one hybrid breaker is employed at each dc line. The simulations show that the MLB is feasible and that the overall MTdc grid fault response for the two protection systems is very similar. As a result, the design advantages of the MLB make it a promising solution for the dc fault isolation in MTdc grids.
1 November 2018 in IEEE Transactions on Smart Grid
Low voltage dc distribution grids face issues associated with arc faults, aggravated by the absence of current zero crossing. The focus of this paper is to comprehensively develop a method of series arc fault detection at the load side power electronics, based on the electrode dependent initial voltage drop occurring at the arc initiation. The proposed arc detection algorithm is described along with the structure and time constants of the designed bandpass filter. The operational boundaries of the arc detection algorithm are defined for copper electrodes depending on the set threshold voltage and the system parameters, like grid inductance, resistance, and the load capacitance. Further, the detection time and the zone of guaranteed positive detection are depicted. These are validated through test simulations on the state space model of the system. Finally, experimental validation of the proposed scheme is carried out, wherein, a series arc is generated in the dc circuit and the programmed micro-controller provides a real time signal upon detecting the arcing event. The results on variation in detection time with set threshold voltage are also presented experimentally.
4 January 2018 in IEEE Access
The emergence of distributed energy resources can lead to congestion in distribution grids. DC distribution grids are becoming more relevant as more sources and loads connected to the low voltage grid use dc. Bipolar dc distribution grids with asymmetric loading can experience partial congestion resulting in a nodal price difference between the two polarities if a respective market model is applied. In order to take into account this price difference, this paper presents an optimal power flow (OPF) model formulated in terms of voltage and current. In the case of bipolar dc distribution grids, the single line approximation is no longer valid because current can flow in the neutral conductors as well. Moreover, loads and sources can be connected between any two nodes in the network. The proposed exact OPF formulation includes bilinear equations. The locational marginal prices (LMP) are derived by linearizing the problem at the optimal solution. Example cases show the various phenomena that can appear under asymmetric loading, such as pole-to-pole connections combined with pole-to-neutral connections, parallel sources, meshed grids and their effect on the LMP.
30 January 2018 in IEEE Transactions on Power Delivery
In dc distribution grids residual ground current protection is more feasible than in ac distribution grids, where stray capacitance leads to significant ac ground currents. However, when meshing dc distribution grids, circulating net currents can appear that resemble residual ground currents and would trip traditional protection schemes. This letter introduces this phenomenon in both unipolar and bipolar dc distribution grids. Furthermore, worst case net current magnitudes are derived and examples shown. Implications for measurement and protection devices are discussed.
15 June 2017 in Electric Power Components and Systems
LRLaura M. Ramirez-Elizondo
Laura M. Ramirez-Elizondo
This paper describes the behavior of voltage weak DC distribution systems. These systems have relatively small system capacitance. The size of system capacitance, which stores energy, has a considerable effect on the value of fault currents, control complexity, and system reliability. A number of potential definitions of voltage weak DC distribution systems are proposed. These definitions address the main characteristics of voltage weak systems. A small signal model of a general voltage weak DC distribution system is developed in order to observe sufficient conditions for system stability. This is achieved by analyzing the dominant poles. The source converters are modeled as droop-controlled current sources in parallel with their respective terminal capacitors. As constant power loads have incremental negative impedances, which affect the system stability, especially, in voltage weak system, ideal constant power loads with their terminal capacitors are included in the small signal model. A three-node voltage weak DC distribution grid is analyzed, as a case study, by implementing the developed small signal model. The effects on system stability by the values of system capacitance, cable inductance, and cable resistance are investigated using dominant pole placement. Likewise, the influence of proportional-integral regulators and droop coefficients of source converters on the stability of the system is examined. Finally, the three node DC distribution grid is developed in MATLAB/Simulink in order to demonstrate the influence of small capacitance on system stability. Moreover, effect of the rate of change of constant power loads on the system stability is simulated. These results are further compared and verified on a voltage weak DC experimental test bench with a 350 VDC bus voltage.