Yee Kai Tee

Dr. Yee Kai Tee

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2014 in Brain
Verified
Journal Article
Open access
PDF file
GHGeorge W. J. Harston
George W. J. Harston
YTYee Kai Tee
Yee Kai Tee
NBNicholas Blockley
Nicholas Blockley
TOThomas W. Okell
Thomas W. Okell
STSivarajan Thandeswaran
Sivarajan Thandeswaran
JKJames Kennedy
James Kennedy
The original concept of the ischaemic penumbra suggested imaging of regional cerebral blood flow and metabolism would be required to identify tissue that may benefit from intervention. Amide proton transfer magnetic resonance imaging, a chemical exchange saturation transfer technique, has been used to derive cerebral intracellular pH in preclinical stroke models and has been proposed as a metabolic marker of ischaemic penumbra. In this proof of principle clinical study, we explored the potential of this pH-weighted magnetic resonance imaging technique at tissue-level. Detailed voxel-wise analysis was performed on data from a prospective cohort of 12 patients with acute ischaemic stroke. Voxels within ischaemic core had a more severe intracellular acidosis than hypoperfused tissue recruited to the final infarct (P < 0.0001), which in turn was more acidotic than hypoperfused tissue that survived (P < 0.0001). In addition, when confined to the grey matter perfusion deficit, intracellular pH (P < 0.0001), but not cerebral blood flow (P = 0.31), differed between tissue that infarcted and tissue that survived. Within the presenting apparent diffusion coefficient lesion, intracellular pH differed between tissue with early apparent diffusion lesion pseudonormalization and tissue with true radiographic recovery. These findings support the need for further investigation of pH-weighted imaging in patients with acute ischaemic stroke.

1 January 2021 in Computational Intelligence and Neuroscience
Verified
Journal Article
Open access
PDF file
PYPauline Shan Qing Yeoh
Pauline Shan Qing Yeoh
KLKhin wee Lai
Khin wee Lai
SGSiew Li Goh
Siew Li Goh
KHKhairunnisa Hasikin
Khairunnisa Hasikin
YHYan Chai Hum
Yan Chai Hum
DSDhanalakshmi Samiappan
Dhanalakshmi Samiappan
Osteoarthritis (OA), especially knee OA, is the most common form of arthritis, causing significant disability in patients worldwide. Manual diagnosis, segmentation, and annotations of knee joints remain as the popular method to diagnose OA in clinical practices, although they are tedious and greatly subject to user variation. Therefore, to overcome the limitations of the commonly used method as above, numerous deep learning approaches, especially the convolutional neural network (CNN), have been developed to improve the clinical workflow efficiency. Medical imaging processes, especially those that produce 3‐dimensional (3D) images such as MRI, possess ability to reveal hidden structures in a volumetric view. Acknowledging that changes in a knee joint is a 3D complexity, 3D CNN has been employed to analyse the joint problem for a more accurate diagnosis in the recent years. In this review, we provide a broad overview on the current 2D and 3D CNN approaches in the OA research field. We reviewed 74 studies related to classification and segmentation of knee osteoarthritis from the Web of Science database and discussed the various state‐of‐the‐art deep learning approaches proposed. We highlighted the potential and possibility of 3D CNN in the knee osteoarthritis field. We concluded by discussing the possible challenges faced as well as the potential advancements in adopting 3D CNNs in this field.

10 June 2014 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
YTYee Kai Tee
Yee Kai Tee
GHG. W. J. Harston
G. W. J. Harston
NBNicholas Blockley
Nicholas Blockley
TOThomas W. Okell
Thomas W. Okell
JLJ. Levman
J. Levman
MCM. A. Chappell
M. A. Chappell
Amide proton transfer (APT) imaging is a pH mapping method based on the chemical exchange saturation transfer phenomenon that has potential for penumbra identification following stroke. The majority of the literature thus far has focused on generating pH‐weighted contrast using magnetization transfer ratio asymmetry analysis instead of quantitative pH mapping. In this study, the widely used asymmetry analysis and a model‐based analysis were both assessed on APT data collected from healthy subjects (n = 2) and hyperacute stroke patients (n = 6, median imaging time after onset = 2 hours 59 minutes). It was found that the model‐based approach was able to quantify the APT effect with the lowest variation in grey and white matter (≤ 13.8 %) and the smallest average contrast between these two tissue types (3.48 %) in the healthy volunteers. The model‐based approach also performed quantitatively better than the other measures in the hyperacute stroke patient APT data, where the quantified APT effect in the infarct core was consistently lower than in the contralateral normal appearing tissue for all the patients recruited, with the group average of the quantified APT effect being 1.5 ± 0.3 % (infarct core) and 1.9 ± 0.4 % (contralateral). Based on the fitted parameters from the model‐based analysis and a previously published pH and amide proton exchange rate relationship, quantitative pH maps for hyperacute stroke patients were generated, for the first time, using APT imaging. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.

21 July 2023 in Scientia Horticulturae
Verified
Journal Article
Closed access
YGYee Sin Goh
Yee Sin Goh
YHYan Chai Hum
Yan Chai Hum
YLYing Loong Lee
Ying Loong Lee
KLKhin Wee Lai
Khin Wee Lai
WYWun-She Yap
Wun-She Yap
YTYee Kai Tee
Yee Kai Tee

1 January 2019 in NeuroImage: Clinical
Verified
Journal Article
Open access
YMY. Msayib
Y. Msayib
GHG.W.J. Harston
G.W.J. Harston
YTYee Kai Tee
Yee Kai Tee
FSF. Sheerin
F. Sheerin
NBN.P. Blockley
N.P. Blockley
MCM.A. Chappell
M.A. Chappell
Amide proton transfer (APT) imaging may help identify the ischaemic penumbra in stroke patients, the classical definition of which is a region of tissue around the ischaemic core that is hypoperfused and metabolically stressed. Given the potential of APT imaging to complement existing imaging techniques to provide clinically-relevant information, there is a need to develop analysis techniques that deliver a robust and repeatable APT metric. The challenge to accurate quantification of an APT metric has been the heterogeneous in-vivo environment of human tissue, which exhibits several confounding magnetisation transfer effects including spectrally-asymmetric nuclear Overhauser effects (NOEs). The recent literature has introduced various model-free and model-based approaches to analysis that seek to overcome these limitations. The objective of this work was to compare quantification techniques for CEST imaging that specifically separate APT and NOE effects for application in the clinical setting. Towards this end a methodological comparison of different CEST quantification techniques was undertaken in healthy subjects, and around clinical endpoints in a cohort of acute stroke patients. MRI data from 12 patients presenting with ischaemic stroke were retrospectively analysed. Six APT quantification techniques, comprising model-based and model-free techniques, were compared for repeatability and ability for APT to distinguish pathological tissue in acute stroke. Robustness analysis of six quantification techniques indicated that the multi-pool model-based technique had the smallest contrast between grey and white matter (2%), whereas model-free techniques exhibited the highest contrast (>30%). Model-based techniques also exhibited the lowest spatial variability, of which 4-pool APTR∗ was by far the most uniform (10% coefficient of variation, CoV), followed by 3-pool analysis (20%). Four-pool analysis yielded the highest ischaemic core contrast-to-noise ratio (0.74). Four-pool modelling of APT effects was more repeatable (3.2% CoV) than 3-pool modelling (4.6% CoV), but this appears to come at the cost of reduced contrast between infarct growth tissue and normal tissue. The multi-pool measures performed best across the analyses of repeatability, spatial variability, contrast-to-noise ratio, and grey matter-white matter contrast, and might therefore be more suitable for use in clinical imaging of acute stroke. Addition of a fourth pool that separates NOEs and semisolid effects appeared to be more biophysically accurate and provided better separation of the APT signal compared to the 3-pool equivalent, but this improvement appeared be accompanied by reduced contrast between infarct growth tissue and normal tissue.

24 September 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MCMichael A. Chappell
Michael A. Chappell
MDManus J. Donahue
Manus J. Donahue
YTYee Kai Tee
Yee Kai Tee
AKAlexandre A. Khrapitchev
Alexandre A. Khrapitchev
NSNicola R. Sibson
Nicola R. Sibson
SPStephen J. Payne
Stephen J. Payne
Amide Proton Transfer (APT) reports on contrast derived from the exchange of protons between amide groups and water. Commonly, APT contrast is quantified by asymmetry analysis, providing an ensemble contrast of both amide proton concentration and exchange rate. An alternative is to sample the off‐resonant spectrum and fit an exchange model, permitting the APT effect to be quantified, correcting automatically for confounding effects of spillover, field inhomogeneity, and magnetization transfer. Additionally, it should permit amide concentration and exchange rate to be independently quantified. Here, a Bayesian method is applied to this problem allowing pertinent prior information to be specified. A three‐pool model was used incorporating water protons, amide protons, and magnetization transfer effect. The method is demonstrated in simulations, creatine phantoms with varying pH and in vivo (n = 7). The Bayesian model‐based approach was able to quantify the APT effect accurately (root‐mean‐square error < 2%) even when subject to confounding field variation and magnetization transfer effect, unlike traditional asymmetry analysis. The in vivo results gave approximate APT concentration (relative to water) and exchange rate values of 3 × 10−3 and 15 s−1. A degree of correlation was observed between these parameter making the latter difficult to quantify with absolute accuracy, suggesting that more optimal sampling strategies might be required. Magn Reson Med 70:556–567, 2013.