Marco Guermandi

Dr. Marco Guermandi

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2021 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
DRDavide Rossi
Davide Rossi
FCFrancesco Conti
Francesco Conti
MEManuel Eggiman
Manuel Eggiman
AMAlfio Di Mauro
Alfio Di Mauro
Giuseppe TagliaviniGiuseppe Tagliavini
Giuseppe Tagliavini
LBLuca Benini
Luca Benini
The Internet-of-Things (IoT) requires endnodes with ultra-low-power always-on capability for a long battery lifetime, as well as high performance, energy efficiency, and extreme flexibility to deal with complex and fast-evolving near-sensor analytics algorithms (NSAAs). We present Vega, an IoT endnode system on chip (SoC) capable of scaling from a 1.7- $\mu \text{W}$ fully retentive cognitive sleep mode up to 32.2-GOPS (at 49.4 mW) peak performance on NSAAs, including mobile deep neural network (DNN) inference, exploiting 1.6 MB of state-retentive SRAM, and 4 MB of non-volatile magnetoresistive random access memory (MRAM). To meet the performance and flexibility requirements of NSAAs, the SoC features ten RISC-V cores: one core for SoC and IO management and a nine-core cluster supporting multi-precision single instruction multiple data (SIMD) integer and floating-point (FP) computation. Vega achieves the state-of-the-art (SoA)-leading efficiency of 615 GOPS/W on 8-bit INT computation (boosted to 1.3 TOPS/W for 8-bit DNN inference with hardware acceleration). On FP computation, it achieves the SoA-leading efficiency of 79 and 129 GFLOPS/W on 32- and 16-bit FP, respectively. Two programmable machine learning (ML) accelerators boost energy efficiency in cognitive sleep and active states.

9 July 2019 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
VKVictor Kartsch
Victor Kartsch
Giuseppe TagliaviniGiuseppe Tagliavini
Giuseppe Tagliavini
MGMarco Guermandi
Marco Guermandi
SBSimone Benatti
Simone Benatti
DRDavide Rossi
Davide Rossi
LBLuca Benini
Luca Benini
Advancements in Digital Signal Processing (DSP) and machine learning techniques have boosted the popularity of Brain-Computer Interfaces (BCIs), where electroencephalography (EEG) is a widely accepted method to enable intuitive human-machine interaction. Nevertheless, the evolution of such interfaces is currently hampered by the unavailability of embedded platforms capable of delivering the required computational power at high energy efficiency and allowing for a small and unobtrusive form factor. To fill this gap, we developed BioWolf, a highly wearable (40x20x2mm) BCI platform based on Mr. Wolf, a Parallel Ultra Low Power system on chip featuring nine RISC-V cores with DSP-oriented instruction set extensions. BioWolf also integrates a commercial 8-channel medical-grade analog-to-digital converter, and an ARM-Cortex M4 microcontroller unit (MCU) with Bluetooth low-energy connectivity. To demonstrate the capabilities of the system, we implemented and tested a BCI featuring Canonical Correlation Analysis (CCA) of steady-state visual evoked potentials (SSVEP). The system achieves an average information transfer rate of 1.46 bits per second (bps) (aligned with the state-of-the-art of bench-top systems). Thanks to the reduced power envelope of the digital computational platform, which consumes less than the analog front-end, the total power budget is just 6.31 mW, providing up to 38 hrs operation (65 mAh battery). To our knowledge, our design is the first to explore the significant energy boost of a parallel MCU with respect to single-core MCUs for CCA-based BCI.

3 August 2018 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
MCMatteo Chiesi
Matteo Chiesi
MGMarco Guermandi
Marco Guermandi
SPSilvio Placati
Silvio Placati
ESEleonora Franchi Scarselli
Eleonora Franchi Scarselli
RGRoberto Guerrieri
Roberto Guerrieri
This paper presents an open source framework called Creamino. It consists of an Arduino-based cost-effective quick-setup EEG platform built with off-the-shelf components and a set of software modules that easily allow users to connect this system to Simulink or BCI-oriented tools (such as BCI2000 or OpenViBE) and set up a wide number of neuroscientific experiments. Creamino is capable of processing multiple EEG channels in real-time and operates under Windows, Linux, and Mac OS X in real-time on a standard PC. Its objective is to provide a system that can be readily fabricated and used for neurophysiological experiments and, at the same time, can serve as the basis for development of novel BCI platforms by accessing and modifying its open source hardware and software libraries. Schematics, gerber files, bill of materials, source code, software modules, demonstration videos, and instructions on how to use these modules are available free of charge for research and educational purposes online at https://github.com/ArcesUnibo/creamino. Application cases show how the system can be used for neuroscientific or BCI experiments. Thanks to its low production cost and its compatibility with open-source BCI tools, the system presented is particularly suitable for use in BCI research and educational applications.

8 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Giacomo PaoliniGiacomo Paolini
Giacomo Paolini
MGMarco Guermandi
Marco Guermandi
Diego MasottiDiego Masotti
Diego Masotti
MSMazen Shanawani
Mazen Shanawani
Francesca BenassiFrancesca Benassi
Francesca Benassi
ACAlessandra Costanzo
Alessandra Costanzo
This work describes the design, implementation, and validation of a wireless sensor network for predictive maintenance and remote monitoring in metal-rich, electromagnetically harsh environments. Energy is provided wirelessly at 2.45 GHz employing a system of three co-located active antennas designed with a conformal shape such that it can power, on-demand, sensor nodes located in non-line-of-sight (NLOS) and difficult-to-reach positions. This allows for eliminating the periodic battery replacement of the customized sensor nodes, which are designed to be compact, low-power, and robust. A measurement campaign has been conducted in a real scenario, i.e., the engine compartment of a car, assuming the exploitation of the system in the automotive field. Our work demonstrates that a one radio-frequency (RF) source (illuminator) with a maximum effective isotropic radiated power (EIRP) of 27 dBm is capable of transferring the energy of 4.8 mJ required to fully charge the sensor node in less than 170 s, in the worst case of 112-cm distance between illuminator and node (NLOS). We also show how, in the worst case, the transferred power allows the node to operate every 60 s, where operation includes sampling accelerometer data for 1 s, extracting statistical information, transmitting a 20-byte payload, and receiving a 3-byte acknowledgment using the extremely robust Long Range (LoRa) communication technology. The energy requirement for an active cycle is between 1.45 and 1.65 mJ, while sleep mode current consumption is less than 150 nA, allowing for achieving the targeted battery-free operation with duty cycles as high as 1.7%.

19 August 2018 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
MSMattia Salvaro
Mattia Salvaro
SBSimone Benatti
Simone Benatti
VKVictor J. Kartsch
Victor J. Kartsch
MGMarco Guermandi
Marco Guermandi
LBLuca Benini
Luca Benini
A growing trend in human-computer interaction is to integrate computational capabilities into wearable devices, to enable sophisticated and natural interaction modalities. Acting directly by decoding neural activity is a very natural way of interaction and one of the fundamental paradigms of brain computer interfaces (BCIs) as well. In this paper, we present a wearable Internet of Things node designed for BCI spelling. The system is based on visual evoked potentials detection and runs the canonical correlation analysis on a low power microcontroller. Neural data is acquired by an array of electroencephalography active dry electrodes, suitable for a minimally intrusive interface. To evaluate our solution, we optimized the system on eight subjects and tested it on five different subjects for four and eight stimuli, reaching a peak transfer rate of 1.57 b/s, comparable with those achieved by state-of-the-art nonembedded systems. The power consumption of the device is less than 30 mW, resulting in 122 h of operation with a standard 1000-mAh battery.

12 January 2026 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
SFSebastian Frey
Sebastian Frey
GSGiusy Spacone
Giusy Spacone
ACAndrea Cossettini
Andrea Cossettini
MGMarco Guermandi
Marco Guermandi
PSPhilipp Schilk
Philipp Schilk
VKVictor Kartsch
Victor Kartsch
The growing demand for continuous physiological monitoring and human-machine interaction in real-world settings calls for wearable platforms that are flexible, low-power, and capable of on-device intelligence. This work presents BioGAP-Ultra, an advanced multimodal biosensing platform that supports synchronized acquisition of diverse electrophysiological and hemodynamic signals such as EEG, EMG, ECG, and PPG while enabling embedded AI processing at state-of-the-art energy efficiency. BioGAP-Ultra is a major extension of our previous BioGAP design aimed at meeting the rapidly growing requirements of wearable biosensing applications. It features (i) increased on-device storage ($\times$2 SRAM, $\times$4 FLASH), (ii) improved wireless connectivity (supporting up to 1.4 Mbit/s bandwidth, $\times$4 higher than BioGAP), (iii) enhanced number of signal modalities (from 3 to 5) and analog input channels ($\times$2). Further, it is accompanied by a real-time visualization and analysis software suite that supports the hardware design, providing access to raw data and real-time configurability on a mobile phone. Finally, we demonstrate the system’s versatility through integration into various wearable form factors: an EEG-PPG headband consuming 32.8 mW, an EMG sleeve at 26.7 mW, and an ECG-PPG chestband requiring only 9.3 mW for continuous acquisition and streaming, tailored for diverse biosignal applications. To showcase its edge-AI capabilities, we further deploy two representative on-device applications: (1) ECG-PPG-based PAT estimation at 8.6 mW, and (2) EMG-ACC-based classification of reach-and-grasp motion phases, achieving 79.9 % $\pm$ 5.7 % accuracy at 23.6 mW. All hardware and software design files are also released open-source with a permissive license.