Carlos Alberto Fonzar Pintão

Prof. Dr. Carlos Alberto Fonzar Pintão

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
ASAdriana Alencar Santos
Adriana Alencar Santos
JTJean Teixeira
Jean Teixeira
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
DCDiego Rafael Correa
Diego Rafael Correa
Carlos Roberto GrandiniCarlos Roberto Grandini
Carlos Roberto Grandini
PLPaulo Noronha Lisboa-Filho
Paulo Noronha Lisboa-Filho
It is crucial for clinical needs to develop novel titanium alloys feasible for long-term use as orthopedic and dental prostheses to prevent adverse implications and further expensive procedures. The primary purpose of this research was to investigate the corrosion and tribocorrosion behavior in the phosphate buffered saline (PBS) of two recently developed titanium alloys, Ti–15Zr and Ti–15Zr–5Mo (wt.%) and compare them with the commercially pure titanium grade 4 (CP–Ti G4). Density, XRF, XRD, OM, SEM, and Vickers microhardness analyses were conducted to give details about the phase composition and the mechanical properties. Additionally, electrochemical impedance spectroscopy was used to supplement the corrosion studies, while confocal microscopy and SEM imaging of the wear track were used to evaluate the tribocorrosion mechanisms. As a result, the Ti–15Zr (α + α′ phase) and Ti–15Zr–5Mo (α″ + β phase) samples exhibited advantageous properties compared to CP–Ti G4 in the electrochemical and tribocorrosion tests. Moreover, a better recovery capacity of the passive oxide layer was observed in the studied alloys. These results open new horizons for biomedical applications of Ti–Zr–Mo alloys, such as dental and orthopedical prostheses.

18 March 2004 in European Journal of Physics
Verified
Journal Article
Closed access
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
MFMoacir P de Souza Filho
Moacir P de Souza Filho
Carlos Roberto GrandiniCarlos Roberto Grandini
Carlos Roberto Grandini
RHRoberto Hessel
Roberto Hessel
In this work, we describe an experimental setup in which an electric current is used to determine the angular velocity attained by a plate rotating around a shaft in response to a torque applied for a given period. Based on this information, we show how the moment of inertia of a plate can be determined using a procedure that differs considerably from the ones most commonly used, which generally involve time measurements. Some experimental results are also presented which allow one to determine parameters such as the exponents and constant of the conventional equation of a plate's moment of inertia.

15 April 2004 in Materials Science and Engineering: A
Verified
Journal Article
Closed access
LAL.H. Almeida
L.H. Almeida
TNT.C. Niemeyer
T.C. Niemeyer
KPK.C.C. Pires
K.C.C. Pires
Carlos Roberto GrandiniCarlos Roberto Grandini
Carlos Roberto Grandini
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
OFODILA FLORENCIO
ODILA FLORENCIO

1 July 2000 in Journal of Applied Physics
Verified
Journal Article
Closed access
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
RHRoberto Hessel
Roberto Hessel
The secondary electron emission of dielectrics usually is measured by the pulse method, in which the dielectric is irradiated with short pulses of electrons. Attempts to use a dynamic method, in which the dielectric is irradiated continuously, have failed because the dielectric becomes charged and this charge interferes with the emission process. The dynamic method can, however, be applied to metals where volume charges are prevented. This article reports dynamic measurements of the total secondary emission yield from stainless steel, platinum, and aluminum and compares them with results from the current pulse method. In order to apply the dynamic method to metals a simple but important change in the setup was introduced: a dielectric slab was placed between the electrode and the metallic sample, which permitted the sample surface potential and therefore the energy of the incident electrons to change continuously. Unlike for dielectrics, the emission curves for metals are identical when obtained by the two methods. However, for a sample with deliberately oxidized surfaces the total secondary emission yield is smaller when measured with the dynamic method as compared with the pulse method, just as happens for dielectrics.

16 February 2023 in Metals
Verified
Journal Article
Open access
PDF file
ASAdriana Alencar Santos
Adriana Alencar Santos
JTJean Teixeira
Jean Teixeira
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
Elidiane Cipriano RangelElidiane Cipriano Rangel
Elidiane Cipriano Rangel
NCNilson C Cruz
Nilson C Cruz
PLPaulo Noronha Lisboa-Filho
Paulo Noronha Lisboa-Filho
Titanium (Ti) and its alloys are widely used in biomedical applications due to their excellent mechanical properties and biocompatibility. However, they are a concern due to the possibility of cytotoxic effects coming from the degradation products. This degradation occurs by the combined action of corrosion and mechanical wear of these materials, which are released in the biological environment by the biomaterial implanted. The present article aims to investigate a new route to improve electrochemical and tribological performance with surface modification. Regarding the deposition of a protective layer on the surface, it consists of titanium oxide (TiO2) and calcium phosphate (CaP). Both coatings were performed by chronoamperometric methods with titanium oxidation at 1 V and calcium phosphate reduction at −1.5 V. The corrosion and tribocorrosion tests demonstrated the effective combination of TiO2 and CaP layer to protect the Ti substrate. Furthermore, this coating combination reduced corrosion degradation and mechanical wear in PBS, simulating a physiological environment. Additionally, it was observed that this combination of coating decreased the dissipated energy, and consequently, the wear decreased during sliding tests. All these findings indicate the protective behavior of the TiO2 and CaP layer during the tribocorrosion tests.

9 March 2009 in Materials Science and Engineering: A
Verified
Journal Article
Closed access
MIM. Imaizumi
M. Imaizumi
CSC.A. Soufen
C.A. Soufen
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
LVLaudemir Carlos Varanda
Laudemir Carlos Varanda
MJM. Jafelicci
M. Jafelicci