Jean Teixeira

Ms. Jean Teixeira


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 February 2023 in Materials
Verified
Journal Article
Open access
PDF file
ASAdriana Alencar Santos
Adriana Alencar Santos
JTJean Teixeira
Jean Teixeira
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
DCDiego Rafael Correa
Diego Rafael Correa
Carlos Roberto GrandiniCarlos Roberto Grandini
Carlos Roberto Grandini
PLPaulo Noronha Lisboa-Filho
Paulo Noronha Lisboa-Filho
It is crucial for clinical needs to develop novel titanium alloys feasible for long-term use as orthopedic and dental prostheses to prevent adverse implications and further expensive procedures. The primary purpose of this research was to investigate the corrosion and tribocorrosion behavior in the phosphate buffered saline (PBS) of two recently developed titanium alloys, Ti–15Zr and Ti–15Zr–5Mo (wt.%) and compare them with the commercially pure titanium grade 4 (CP–Ti G4). Density, XRF, XRD, OM, SEM, and Vickers microhardness analyses were conducted to give details about the phase composition and the mechanical properties. Additionally, electrochemical impedance spectroscopy was used to supplement the corrosion studies, while confocal microscopy and SEM imaging of the wear track were used to evaluate the tribocorrosion mechanisms. As a result, the Ti–15Zr (α + α′ phase) and Ti–15Zr–5Mo (α″ + β phase) samples exhibited advantageous properties compared to CP–Ti G4 in the electrochemical and tribocorrosion tests. Moreover, a better recovery capacity of the passive oxide layer was observed in the studied alloys. These results open new horizons for biomedical applications of Ti–Zr–Mo alloys, such as dental and orthopedical prostheses.

16 February 2023 in Metals
Verified
Journal Article
Open access
PDF file
ASAdriana Alencar Santos
Adriana Alencar Santos
JTJean Teixeira
Jean Teixeira
CPCarlos Alberto Fonzar Pintão
Carlos Alberto Fonzar Pintão
Elidiane Cipriano RangelElidiane Cipriano Rangel
Elidiane Cipriano Rangel
NCNilson C Cruz
Nilson C Cruz
PLPaulo Noronha Lisboa-Filho
Paulo Noronha Lisboa-Filho
Titanium (Ti) and its alloys are widely used in biomedical applications due to their excellent mechanical properties and biocompatibility. However, they are a concern due to the possibility of cytotoxic effects coming from the degradation products. This degradation occurs by the combined action of corrosion and mechanical wear of these materials, which are released in the biological environment by the biomaterial implanted. The present article aims to investigate a new route to improve electrochemical and tribological performance with surface modification. Regarding the deposition of a protective layer on the surface, it consists of titanium oxide (TiO2) and calcium phosphate (CaP). Both coatings were performed by chronoamperometric methods with titanium oxidation at 1 V and calcium phosphate reduction at −1.5 V. The corrosion and tribocorrosion tests demonstrated the effective combination of TiO2 and CaP layer to protect the Ti substrate. Furthermore, this coating combination reduced corrosion degradation and mechanical wear in PBS, simulating a physiological environment. Additionally, it was observed that this combination of coating decreased the dissipated energy, and consequently, the wear decreased during sliding tests. All these findings indicate the protective behavior of the TiO2 and CaP layer during the tribocorrosion tests.

27 March 2019 in Materials Research Express
Verified
Journal Article
Closed access
PDF file
FPFernanda Malato Praxedes
Fernanda Malato Praxedes
JTJean Teixeira
Jean Teixeira
PLPatrícia Teresa Souza da Luz
Patrícia Teresa Souza da Luz
OFOscar Jesus Choque Fernandez
Oscar Jesus Choque Fernandez
BFBruno Apolo Miranda Figueira
Bruno Apolo Miranda Figueira
SASandra Maria Santos de Oliveira Araújo
Sandra Maria Santos de Oliveira Araújo

7 January 2021 in Nanomedicine
Verified
Journal Article
Closed access
JTJean Teixeira
Jean Teixeira
F.Raquel MaiaF.Raquel Maia
F.Raquel Maia
MCMariana Carvalho
Mariana Carvalho
RRRui M. Reis
Rui M. Reis
Joaquim OliveiraJoaquim Oliveira
Joaquim Oliveira
ACANA PAULA ROSIFINI ALVES CLARO
ANA PAULA ROSIFINI ALVES CLARO
Aim: To established a simple, controlled and reproducible method to synthesize gallium (Ga)-coated polydopamine (PDA) nanoparticles (NPs). Materials & methods: PDA NPs were synthesized in alkali me... Graphical abstract

19 December 2024 in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
Verified
Journal Article
Closed access
JTJean Teixeira
Jean Teixeira
ASAdriana A. Santos
Adriana A. Santos
BPBruna O. Pinto
Bruna O. Pinto
GCGuilherme R. Capelin
Guilherme R. Capelin
CPCarlos A. F. Pintão
Carlos A. F. Pintão
PLPaulo N. Lisboa-Filho
Paulo N. Lisboa-Filho
Developing new titanium alloys and studying their feasibility for dental implants and orthopedic prostheses has been essential to avoid side effects and additional expensive surgeries. The goal of this contribution is to report the tribological behavior of two groups of alloys developed via arc melting, Ti-15Zr and Ti-15Zr-5Mo. To compare the performance of the studied biomaterials, the surface preparation was performed using metallographic techniques. Subsequently, the XRD and microhardness tests were performed to complement the experiments. The tribological tests were accomplished with microscopic analysis to understand the surface modifications. The results indicated that both Ti-15Zr and Ti-15Zr-5Mo alloys showed promising potential, with ternary alloy presenting better performance at low load (1.5 N), with binary alloys presenting superior performance at higher load until 15 N.

1 January 2023 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
PDF file
GCGuilherme Ribeiro Capelin
Guilherme Ribeiro Capelin
MNMilena Yumi Kasama Nakata
Milena Yumi Kasama Nakata
JTJean Teixeira
Jean Teixeira
ASAdriana Alencar Santos
Adriana Alencar Santos
PLPaulo Noronha Lisboa-Filho
Paulo Noronha Lisboa-Filho
Atualmente, o substrato de titânio é um dos mais importantes biomateriais metálicos com aplicação em ortopedia, odontologia, fixação de fraturas e artroplastia de joelho e quadril. Apesar de todas estas propriedades atrativas, sua inércia biológica e baixa capacidade bactericida acaba limitando sua osseointegração. Neste sentido, revestimentos de TiO2 e TiO2(MgO) são realizados para aprimorar as características do titânio, como a resistência à corrosão. Os objetivos deste estudo foram analisar a resistência à corrosão do óxido de titânio e óxido de titânio com adição de magnésio, topografias, morfologias e cristalinidade em um substrato de titânio através da eletrodeposição com corrente constante. As eletrodeposições foram realizadas em um sistema de três eletrodos, sendo o titânio eletrodo de trabalho, Ag/AgCl como eletrodo de referência e um contra eletrodo de platina em um potenciostato e foram utilizadas correntes constantes de 1,0 mA/cm2 para todos os processos. Foram utilizadas as caracterizações por microscopia eletrônica de varredura (MEV), microscopia de força atômica (MFA), microscopia confocal, difração de raios X (DRX) e polarização potenciodinâmica. As análises de topografia e morfologia indicaram uma alteração nas rugosidades (Ra) e todas demonstraram uma superfície uniforme. As análises de DRX indicaram apenas o titânio metálico, porém todas tiveram uma diferença no FWHM, indicando possíveis fases amorfas ou Mg intersticial, causando também uma variação na altura dos picos. Por fim, a polarização potenciodinâmica indicou que o revestimento com TiO2 houve uma melhora de 37,90% e o TiO2 com adição de magnésio houve uma perda de 13,43%. Portanto, os revestimentos causaram alterações nas rugosidades, morfologias, redes cristalinas e nas propriedades anticorrosivas, possibilitando assim a modulação das propriedades desejadas de acordo com o ambiente de oxidação utilizado.