Wei Sha

Dr. Wei Sha


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
WTWei Tao
Wei Tao
XDXiaoqin Deng
Xiaoqin Deng
YDYuqing Diao
Yuqing Diao
RGRuihong Gao
Ruihong Gao
KQKeqi Qi
Keqi Qi
HLHeshan Liu
Heshan Liu
A kind of full-function two-sided optical bench interferometer (OBI) is designed to meet the practical requirements of the Taiji Program for space gravitational wave detection. The main optical paths are arranged on the A-side for transmission and interference, and other optical paths and electronic devices are placed on the B-side. According to the design scheme, we successfully constructed two OBIs by using hydrogen–oxygen catalytic stress-free bonding technology. When the OBI is installed and adjusted, the position and Angle error of the interference beam are controlled within 30 μm and 50 μrad through the self-designed precision mechanical clamping mechanism and beam position measuring device. The built OBI was placed on the vibration isolation platform in the vacuum tank for the stability test. The test results show that the noise of the OBI is less than 10 pm/√Hz in the frequency band of 0.1 Hz to 1 Hz, which meets the noise budget requirements of the Taiji Pathfinder in the middle- and high-frequency band.

10 July 2023 in Photonics
Verified
Journal Article
Open access
PDF file
XDXiaoqin Deng
Xiaoqin Deng
WTWei Tao
Wei Tao
YDYuqing Diao
Yuqing Diao
BSBenliang Sang
Benliang Sang
WSWei Sha
Wei Sha
A photonic integrated interference imaging system (PIIIS) is a computational imager based on Michelson interference and photonic integrated circuits (PICs). In this paper, a PIIIS based on a compact sampling lenslet array that can sample the zero spatial frequency through a single lenslet, densely sample the frequency in the azimuth direction through the configuration of a hierarchical multistage lenslet array, and continuously sample the frequency in the radial direction through a Langford sequence is proposed. We introduce the design process of the compact sampling lenslet array in detail and simulate the imaging of the system. The simulation results demonstrate that the lenslet array can effectively improve the imaging quality of a PIIIS. In addition, we design a silicon PIC and a silicon nitride transition PIC that match the compact sampling lenslet array and simulate the imaging of the system under the influence of the on-chip optical loss of PICs (the average interference baseline loss is 15.4 dB at 1550 nm). The results show that on-chip optical loss mainly affects the brightness and contrast of the reconstructed image but has little effect on the structure.

11 October 2023 in Machines
Verified
Journal Article
Open access
PDF file
YDYuqing Diao
Yuqing Diao
WTWei Tao
Wei Tao
XDXiaoqin Deng
Xiaoqin Deng
WSWei Sha
Wei Sha
The support structure between payloads is an important part of a space gravitational wave detection satellite, and its thermal stability will directly affect the interferometer’s measurement accuracy. However, due to temperature changes, the connecting structure between the loads will generate deformation, and a support structure with the coefficient of thermal expansion (CTE) of −1 × 10−6/K will thus need to be designed to counteract this thermal deformation. In order to solve this problem, this paper adopts the method of mutual offsetting of the thermal deformation of different materials to design a thermally stable support structure satisfying this negative CTE. The structure was optimized by the arithmetic of non-linear programming by the quadratic Lagrangian hybrid algorithm (NLPQL), and the structural parameter satisfying the CTE of −1.008 × 10−6/K was obtained. Meanwhile, the effect of the change in the thermal expansion coefficient of each material on the overall structure under this parameter was sampled and calculated. Moreover, the experimental results show that the CTE of the support structure under the optimized parameters was −1.114 × 10−6/K, which differs from the simulation results by 9.5%.

24 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
BSBenliang Sang
Benliang Sang
XDXiaoqin Deng
Xiaoqin Deng
WTWei Tao
Wei Tao
YDYuqing Diao
Yuqing Diao
WSWei Sha
Wei Sha
The telescope is the core device for space gravitational wave detection. It is responsible for receiving signal light and emitting outgoing light simultaneously. When the high-energy outgoing laser passes through the telescope, it would produce stray light, which would interfere with the phase measurement and generate phase noise. Therefore, it is necessary to analyze and suppress the stray light of the telescope. In this paper, the requirement of point source transmittance (PST) of the Taiji telescope is obtained through theoretical derivation, which is less than 4×10−10. Through a complete analysis of stray light, we determined that the M4 was the largest source of stray light under the condition that the roughness of each optical surface is equal, which accounted for 67.22%. We also determined the most lenient requirements for surface roughness σλ, and found that when σλ of the M1, M2, M3, and M4 were 20 Å, 4 Å, 1 Å, and 1 Å, respectively, the PST was 3.89×10−10, which met the PST requirement. Next, we calculated the effect of particulate contamination on the PST, and based on the results of our analysis, we determined that the cleanliness level of the testing and storage environment of the Taiji telescope was better than 300. Finally, we evaluated the changes in the PST caused by the damage of micrometeoroids, and the analysis results showed that the stray light level would not change significantly during the service period of the Taiji Telescope.

19 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
KWKangmin Wen
Kangmin Wen
LWLingjie Wang
Lingjie Wang
XZXuefeng Zeng
Xuefeng Zeng
YLYang Liu
Yang Liu
WLWenyan Li
Wenyan Li
DZDi Zhou
Di Zhou
Aiming at the inherent nature and complexity of the influence of in-orbit micro-vibration in the imaging quality of segmented telescopes, a dynamic full-link opto-mechanical integration analysis method is proposed. The method is based on the measured micro-vibration signals of the infrared refrigerator, using the finite element method to perform the transient response analysis of the opto-mechanical system in Patran/Nastran software. The interface tool is written by Matlab to achieve the calculation of rigid body displacement and real-time data interaction with Zemax. The results show that when the working wavelength is 1 μm, the optical system has a wavefront error Root-Mean-Square value of less than 0.071λ in 4 s. Evaluating the effect of micro-vibration on the imaging quality of the system in terms of the peak ratio of the point spread function. When the exposure time was 2 s, the ratio maximum values of 0.4628 and 0.6207 were reached for the X-axis and Y-axis, respectively. The method provides an important reference basis for the evaluation of imaging quality of an optical system under micro-vibration environment with a long exposure time.

10 September 2024 in Research Square
Verified
Preprint
Open access
PDF file
ZLziren luo
ziren luo
HLHe Shan Liu
He Shan Liu
JWJuan Wang
Juan Wang
WTWei Tao
Wei Tao
KQKe Qi Qi
Ke Qi Qi
WHWen Rui Hu
Wen Rui Hu
In this study, we developed and constructed the first-generation ultrastable optical bench (OB) for the Taiji program. The OB uses optical bonding technology, and for the first time, noise testing and calibration were performed. A comprehensive analysis was carried out on the various noise sources impacting the interferometer system; these sources included laser frequency noise, laser power noise, thermal drift noise, and angular jitter noise. When the environmental conditions fell short of our stringent requirements, an advanced post-data processing technique was employed to effectively reduce both the thermal drift noise and angular coupling noise. The results revealed that the noise level of the interferometer system reached 1.1 pm/Hz1/2 at 1 Hz, 5 pm/Hz1/2 at 0.1 Hz, and 8 pm/Hz1/2 at 0.01 Hz; these levels met the requirements of the Taiji pathfinder mission. Furthermore, a future research proposal was provided, with the aim to meet the full frequency range requirements of the Taiji program.