Hybrid installations with respect to renewable energy sources are becoming more popular due to the stringent requirements for the energy efficiency of buildings. Therefore, the thermomodernization of a district-heating substation was proposed. Several scenarios, including different renewable energies (an air–water heat pump versus a heat pump with photovoltaics), different investment financing (equity or bank credit), and different purposes for heating demand (central heating or central heating with ventilation and domestic hot water), were analyzed. The economic aspects involved the calculations of the payback time and net present value, while the ecological and environmental characteristics were weighed using emission reduction. Each of the analyses resulted in different proposed modernization methods. However, taking both factors together, the computations proved that the most profitable was the scenario with energy demand for heating, domestic hot water, and ventilation purposes financed by means of bank credit with a thermomodernization bonus.
Nowadays, one of the basic requirements for thermally upgraded buildings involves limitation in CO2 emission even by over 90%. To fulfil these criteria, it is necessary to use alternative energy sources and photovoltaics constitutes a reasonable option for this. This paper addresses an analysis of the efficiency and profitability of a photovoltaic system located in the geometric center of Europe-Poland, where the intensity of solar irradiation is not very high compared to other European countries. The difference of total solar radiation density between Poland and Malta is 49.2%, from analysis based on SolarGIS base. The PV Lighthouse calculator was used for global power density and photon current examination for a Polish city and locations of the highest and the lowest solar radiation values, Malta and Finland, respectively. This case study concerns a thermally upgraded building; a gas boiler was replaced by a heat pump supported by an off-grid PV system. To achieve a reduction in CO2 emission of 90%, it is necessary to install 182 PV cells, which generates high investment costs. An investment is entirely profitable with 70% of funding with Simple Pay Back Time, SPBT~7 years although Net Present Value, NPV>0; Internal Rate of Return, IRR=10.6%.
The experiments conducted in a didactic laboratory of the Kielce University of Technology involved temperature distribution measurements on the outer surface of a steel radiator using a thermal imaging camera and thermocouples to compare both investigation methods. The research included registering the parameters for a specific period for each of the four different medium flows. Graphs present the results with the division of the radiator into eight thermal fields. The results present the differences in temperatures between 1.78°C to 3.65°C. The non-contact method with an infrared camera seems more accurate since it is precise for surface temperature measurement.
1 January 2026 in Environmental and Climate Technologies
This paper presents a literature based comparative analysis of the heat transfer performance of heat exchanger systems operating with nanofluids. The study synthesizes and compares the results reported in published experimental and numerical works for different types of heat exchangers: shell and tube and plate heat exchangers. The comparison is based on key parameters including exergy efficiency ηex, overall heat transfer coefficient U , and effectiveness ε. The results are presented as functions of the Reynolds number for laminar, transitional, and turbulent flow regimes, and for different types of nanofluids, including both mono and hybrid suspensions. The analysis shows that WC/DI nanofluids provide the highest overall heat transfer coefficient in plate heat exchangers with U = 1110 W/(m2K) at Re = 525, while 0.1 % Graphene/DI nanofluids achieve the best thermal performance in shell and tube heat exchangers exceeding U values of 0.4 % Fe3O4/DI:EG and 0.4 % ND/DI:EG by 85 W/(m2K) at Re = 3000. For plate heat exchangers 0.4 % ND/DI nanofluid demonstrate the highest effectiveness with ε equals to 62 % at Re = 570, whereas in shell and tube designs the best performance is obtained for 0.1 % GNP nanofluid with effectiveness reaching approximately 97.5 % at Re = 500. Furthermore, the Cu:ZnO/DI hybrid nanofluid achieved the highest exergy efficiency 66 % while other hybrid nanofluids exhibits exergy efficiencies lower by 31–34 % at a comparable Reynolds number. The results confirm the significant influence of nanofluid composition and Reynolds number in optimizing heat transfer efficiency.
This paper describes the thermovision analysis conducted on two types of chimneys: structural steel one and reinforced concrete one located in Kielce Heat and Power Plant, Poland. As a result of the research temperature distribution obtained from the thermograms were shown on the diagrams and analysed along their horizontal direction. It proves, both of the chimneys that were examined are in proper technical condition. The article also discusses the importance of the analysis as a diagnostic tool that allows early-stage detection of structural technical conditions and thermal insulation degradation. A factory’s chimney should work constantly to maintain its operation, since modifications in the production line caused by construction works are high cost and usually difficult to implement. However, analyses are critical to ensure chimneys are well maintained. The literature presents many examples of destructive influence of high temperature on the reinforced concrete chimneys. When failure of chimneys occurs, even the whole plant unit may be closed down. Thermography is then an ideal, non-destructive and cost-effective instrument for structure testing and can therefore be a useful, initial step to locate potential damage.