Hybrid installations with respect to renewable energy sources are becoming more popular due to the stringent requirements for the energy efficiency of buildings. Therefore, the thermomodernization of a district-heating substation was proposed. Several scenarios, including different renewable energies (an air–water heat pump versus a heat pump with photovoltaics), different investment financing (equity or bank credit), and different purposes for heating demand (central heating or central heating with ventilation and domestic hot water), were analyzed. The economic aspects involved the calculations of the payback time and net present value, while the ecological and environmental characteristics were weighed using emission reduction. Each of the analyses resulted in different proposed modernization methods. However, taking both factors together, the computations proved that the most profitable was the scenario with energy demand for heating, domestic hot water, and ventilation purposes financed by means of bank credit with a thermomodernization bonus.
1 September 2022 in Journal of Physics: Conference Series
Thermal comfort is one of the main aspect of human life due to the period of time each of us spends inside of the enclosed room on one hand as well as the health issues connected with the sick building syndrome on the other. Presently, the international standards are based on the Fanger model with calculations of proper indexes according to the inside air parameters as well as characteristics for room users. The paper presents the verification of Fanger model with experimental data obtained from research conducted in 6 classrooms of an intelligent, educational building. The measurements were acquired by means of Testo 400 meter where air parameters such as temperature or humidity were collected. For other evidence the questionnaire was prepared, where respondents presented their thermal sensation together with the information of their clothes present thermal insulation. The results proved that the Fanger model is not precise, since the findings calculated with the international standard differ from those obtained from the questionnaires.
The experiments conducted in a didactic laboratory of the Kielce University of Technology involved temperature distribution measurements on the outer surface of a steel radiator using a thermal imaging camera and thermocouples to compare both investigation methods. The research included registering the parameters for a specific period for each of the four different medium flows. Graphs present the results with the division of the radiator into eight thermal fields. The results present the differences in temperatures between 1.78°C to 3.65°C. The non-contact method with an infrared camera seems more accurate since it is precise for surface temperature measurement.
Thermography is getting more and more popular in many fields of everyday life nowadays. It is successfully applied in heat investigations. Infrared cameras imaging includes thermal analyses of building physics, thermal bridges or insulation improvement inspection. Flir E30 infrared camera was used in order to conduct measurements of two chimneys located in Kielce Power Station in Poland. The first tested facility is a structural steel chimney thermally isolated with mineral wool. The other chimney is built of reinforced concrete material. An infrared camera tests enabled the creation of the diagrams presenting the temperature distribution along the chimneys in different orientations. The research proved the correct functioning of both chimneys.
The increasing cost of energy and the need for low-carbon solutions have strengthened interest in wastewater as a stable and underutilized source of recoverable heat. This study assesses the technical feasibility, economic viability, and environmental benefits of a wastewater heat recovery system based on a case study of the Gorzyce municipal wastewater treatment plant in Poland. Water-to-water heat pump configurations and application scenarios are analyzed together with data-driven forecasting of wastewater outflow using artificial neural networks (MLP and RBF). Operational data from 2025 were used to estimate thermal potential and support system sizing. RBF networks provided more accurate flow forecasts than MLP models, improving reliability of energy recovery planning. Results show that even with a 1 K cooling depth, the annual heat recovery potential reaches about 1.16 GWh. The proposed heat pump system achieved the COP values of 3.0–3.4 and seasonal COP around 3.2, confirming high technical performance supported by stable wastewater temperatures. The recovered heat can fully cover the facility’s heating demand, demonstrating clear technical feasibility. The economic analysis indicates annual savings of about EUR 2310 compared to gas heating, with a simple payback period of roughly 13 years, reduced to 7–8 years when combined with on-site photovoltaics. Environmental benefits include CO2 emission reductions of about 5.5 tones per year. Overall, wastewater heat recovery supported by predictive modeling and renewable electricity is a practical, cost-effective, and environmentally friendly solution for municipal infrastructure.
Building inspections include thermal aspects in order to determine the excessive thermal bridges and thereby lower the heat demand. The examinations can be conducted by means of thermal imaging techniques. The paper presents the analysis of hand-held and UAV (Unmanned Aerial Vehicle) infrared camera during research on public building in Kielce, Poland. The obtained results were compared with each other, which allowed for a detailed comparison of the advantages and disadvantages of both technologies. The temperature distribution along the chosen glass partition presents the same tendency no matter the camera. However, due to the distance and several other aspects, the results received by means of hand-held camera seem to be more reliable.