Bruna Tonin

Dr. Bruna Tonin

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2024 in Dental Materials
Verified
Journal Article
Closed access
ZWZhongyuan Wu
Zhongyuan Wu
KSKe Sun
Ke Sun
WWWenshun Wang
Wenshun Wang
QXQi Xue
Qi Xue
BTBruna Tonin
Bruna Tonin
HWHang Wang
Hang Wang

28 April 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
BTBruna Tonin
Bruna Tonin
JFJing Fu
Jing Fu
YHYiting He
Yiting He
NYNing Ye
Ning Ye
HCHooi Pin Chew
Hooi Pin Chew
AFAlex Fok
Alex Fok

5 April 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
YWYuan Wang
Yuan Wang
ZWZhongyuan Wu
Zhongyuan Wu
TWTing Wang
Ting Wang
JTJing Tian
Jing Tian
ZZZixuan Zhou
Zixuan Zhou
JFJing Fu
Jing Fu

1 March 2020 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
RPRaniel Fernandes Peixoto
Raniel Fernandes Peixoto
BTBruna Tonin
Bruna Tonin
JMJanisse Martinelli
Janisse Martinelli
AMAna Paula Macedo
Ana Paula Macedo
MMMaria da Gloria Chiarello de Mattos
Maria da Gloria Chiarello de Mattos

1 September 2021 in Brazilian Dental Journal
Verified
Journal Article
Open access
BTBruna Tonin
Bruna Tonin
RPRaniel Fernandes Peixoto
Raniel Fernandes Peixoto
JFJing Fu
Jing Fu
BFBruna N de Freitas
Bruna N de Freitas
MMMaria da Gloria Chiarello de Mattos
Maria da Gloria Chiarello de Mattos
Ana Paula MacedoAna Paula Macedo
Ana Paula Macedo
This study evaluated the vertical misfit, passivity, and stress distribution after tightening the screws of different prosthesis. Two implants were used to simulate the rehabilitation of partially edentulous mandible space from the second premolar to the second molar. 40 three-element screw-retained fixed dental prosthesis with distal cantilever were fabricated and divided into four groups according to the method of production of framework (n = 10): G1 = conventional casting one-piece framework, G2 = conventional casting sectioned and laser welding, G3 = conventional casting sectioned and tungsten inert gas (TIG) welding and G4 = framework obtained by CAD/CAM (computer-aided design/computer-aided manufacturing) system. The vertical misfits (both screws tightened) and the passive fit (one screw tightened) were measured under a comparator optical microscope. The data was submitted to Shapiro-Wilk test to enable comparison with ANOVA followed by Tukey with Bonferroni adjust (α = .05). The qualitative analysis of the stress distribution was performed by the photoelastic method. The vertical misfit (both screws tightened) of the G2 (24 μm) and G3 (27 μm) were significantly higher than G4 (10 μm) (p = 0,006). The passive fit (for the non-tightened) of the G1(64 μm) and G3 (61 μm) were significantly higher than the G4 (32 μm) (p=0,009). G1 showed high stress between the implants in the photoelastic analysis and G4 presented lower stress. In conclusion, CAD/CAM method results in less vertical misfit, more passivity, and consequently better stress distribution to the bone.

6 March 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
BFBruna N de Freitas
Bruna N de Freitas
BTBruna Tonin
Bruna Tonin
DZDanilo Zaparolli
Danilo Zaparolli
AFAdriana Cláudia Lapria Faria
Adriana Cláudia Lapria Faria
MTMarcelo Bighetti Toniollo
Marcelo Bighetti Toniollo
Ana Paula MacedoAna Paula Macedo
Ana Paula Macedo