The present study involves experiments and modelling aimed at characterizing the passive structural mechanical behavior of the chronic hypoxic lamb thoracic aorta, whose gestation, birth and postnatal period were carried at high altitude (3600 masl). To this end, the mechanical response was studied via tensile and pressurization tests. The tensile and pressurization tests measurements were used simultaneously to calibrate the material parameters of the Gasser–Holzapfel–Ogden (GHO) hyperelasctic anisotropic constitutive model through an analytical-numerical optimization procedure solved with an evolutionary strategy that guarantees a stable response of the model. The model and procedure of calibration adequately adjust to the material behavior in a wide deformation range with an appropriate physical description. The results of this study predict the mechanical response of the lamb thoracic aorta under generalized loading states like those that can occur in physiological conditions and/or in systemic arterial hypertension. Finally, the novel use of the evolutionary strategy, together with the set of experiments and tools used in this study, provide a robust alternative to validate biomechanical characterizations.
In this work, we propose a reliable and stable procedure to characterize anisotropic hyperelastic materials. For this purpose, a metaheuristic optimization method known as evolutionary strategies is used. The advantage of this technique with respect to traditional methods used for non-linear optimization, such as the Levenberg–Marquardt Method, is that this metaheuristic algorithm is oriented to the global optimization of a problem, is independent of gradients and allows to solve problems with constraints. These features are essential when characterizing hyperelastic materials that have non-linearities and are conditioned to regions of stability. To characterize the mechanical behavior of the arteries analyzed in this work, the anisotropic hyperelastic models of Holzapfel–Gasser–Ogden and Gasser–Holzapfel–Ogden are used. An important point of the analysis is that these models may present a non-physical behavior: this drawback is overcome by defining a new criterion of stabilization in conjunction with the evolutionary strategies. Finally, the finite element simulations are used in conjunction with the evolutionary strategies to characterize experimental data of the artery pressurization test, ensuring that the parameters obtained are stable and representative of the material response.
22 August 2023 in Frontiers in Bioengineering and Biotechnology
This work consists of analyzing the impact of geometrical features (thickness and curvature) on the estimation of circumferential residual stresses in arteries. For this purpose, a specific sample of lamb abdominal artery is chosen for analysis and, through computational tools based on Python libraries, the stress-free geometry is captured after the ring opening test. Numerical simulations are then used to reconstruct the sample in order to estimate the circumferential residual stresses. Then, four stress-free geometry models are analyzed: an ideal geometry, i.e., constant curvature and thickness; a constant curvature and variable thickness geometry; a variable curvature and constant thickness geometry; and a variable curvature and thickness geometry. The numerical results show that models perform well from a geometric point of view, where the most different feature was the closed outer perimeter that differs about 14% from the closed real sample. As far as residual stress is concerned, differences up to 198% were found in more realistic models taking a constant curvature and thickness model as reference. Thus, the analysis of a realistic geometry with highly variable curvature and thickness can introduce, compared to an idealized geometry, significant differences in the estimation of residual stresses. This could indicate that the characterization of arterial residual stresses is not sufficient when considering only the opening angle and, therefore, it is also necessary to incorporate more geometrical variables.
16 April 2025 in Frontiers in Bioengineering and Biotechnology
This study aims to assess the efficacy of melatonin in mitigating the adverse effects of hypobaric hypoxia on the cardiovascular system of neonatal lambs (30 days old). Two groups were considered for this purpose: (i) Melatonin-treated group (N = 5) and (ii) Control group (N = 6) without treatment. All subjects were exposed to hypobaric hypoxia during gestation and perinatal periods, with melatonin administered after birth. The study focused on the carotid artery, a known predictor of cardiovascular risk. Biomechanical tests, morphometric, and histological measurements were conducted, and a numerical model was developed based on the biomechanical data. Key findings showed remodeling effects: Firstly, a realignment of collagen fibers towards a longitudinal direction was observed with melatonin treatment, similar to non-hypoxic arteries. Second, changes in residual stress and ex-vivo luminal radius were noted, aiming to reduce wall stress and increase vascular resistance. These changes indicate an antihypertensive response, reducing the effects of increased blood pressure and flow due to hypobaric hypoxia. This study demonstrates that biomechanical and histomorphometric methodologies effectively assess the beneficial effects of melatonin treatment under hypobaric hypoxia exposure.
RESUMEN Para evaluar de manera fidedigna el riesgo de ruptura de la aorta – junto a los índices de peligrosidad de enfermedades cardiovasculares u otras condiciones extremas y los efectos de posibles tratamientos – se requiere conocer los mecanismos de daño que conducen a ésta. En este trabajo, se caracteriza el daño mecánico del tejido aórtico en condición de hipoxia, analizando numéricamente su respuesta al ser sujeto a un estado de presurización similar al inducido por un ensayo de acopado hidráulico. El comportamiento mecánico de la pared aórtica, se describe mediante un modelo de material hiperelástico con dos direcciones de isotropía transversal y un modelo de daño isótropo; ambos calibrados experimentalmente, a partir de resultados de ensayos de tracción uniaxial previamente reportados, realizados a muestras de aorta torácica de corderos expuestos a hipoxia hipobárica crónica. Se estudia un grupo tratado con melatonina, en contraste a un grupo control. Una vez calibrado el modelo constitutivo, se evalúa su desempeño en la simulación numérica del ensayo de acopado hidráulico, en la cual se analiza la respuesta cuasi-estática de una estructura – en forma de cuarto de disco, fijada en el perímetro curvo – solicitada fuera de su plano por una presión o fuerza por unidad de superficie, permanentemente normal al área de carga. Los datos experimentales y los resultados de las simulaciones numéricas indican, que un tratamiento con melatonina reduce rigidez de la aorta. Adicionalmente, las presiones asociadas al inicio del daño entregadas por la simulación del ensayo son compatibles con una condición de hipertensión arterial.