Claudio Garcia-Herrera

Dr. Claudio Garcia-Herrera

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 March 2012 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
CGClaudio Garcia-Herrera
Claudio Garcia-Herrera
JAJ. M. Atienza
J. M. Atienza
FPFRANCISCO JAVIER ROJO PEREZ
FRANCISCO JAVIER ROJO PEREZ
ECE. Claes
E. Claes
GGGustavo V. Guinea
Gustavo V. Guinea
RBR. L. Burgos
R. L. Burgos
The mechanical properties of aortic wall, both healthy and pathological, are needed in order to develop and improve diagnostic and interventional criteria, and for the development of mechanical models to assess arterial integrity. This study focuses on the mechanical behaviour and rupture conditions of the human ascending aorta and its relationship with age and pathologies. Fresh ascending aortic specimens harvested from 23 healthy donors, 12 patients with bicuspid aortic valve (BAV) and 14 with aneurysm were tensile-tested in vitro under physiological conditions. Tensile strength, stretch at failure and elbow stress were measured. The obtained results showed that age causes a major reduction in the mechanical parameters of healthy ascending aortic tissue, and that no significant differences are found between the mechanical strength of aneurysmal or BAV aortic specimens and the corresponding age-matched control group. The physiological level of the stress in the circumferential direction was also computed to assess the physiological operation range of healthy and diseased ascending aortas. The mean physiological wall stress acting on pathologic aortas was found to be far from rupture, with factors of safety (defined as the ratio of tensile strength to the mean wall stress) larger than six. In contrast, the physiological operation of pathologic vessels lays in the stiff part of the response curve, losing part of its function of damping the pressure waves from the heart.

15 July 2019 in Nature Communications
Verified
Journal Article
Open access
PDF file
TATamara L. Akentjew
Tamara L. Akentjew
CTClaudia Terraza
Claudia Terraza
CSCristian Suazo
Cristian Suazo
JMJekaterina Maksimcuka
Jekaterina Maksimcuka
CWCamila A. Wilkens
Camila A. Wilkens
JCJuan Pablo Acevedo Cox
Juan Pablo Acevedo Cox
Design strategies for small diameter vascular grafts are converging toward native-inspired tissue engineered grafts. A new automated technology is presented that combines a dip-spinning methodology for depositioning concentric cell-laden hydrogel layers, with an adapted solution blow spinning (SBS) device for intercalated placement of aligned reinforcement nanofibres. This additive manufacture approach allows the assembly of bio-inspired structural configurations of concentric cell patterns with fibres at specific angles and wavy arrangements. The middle and outer layers were tuned to structurally mimic the media and adventitia layers of native arteries, enabling the fabrication of small bore grafts that exhibit the J-shape mechanical response and compliance of human coronary arteries. This scalable automated system can fabricate cellularized multilayer grafts within 30 min. Grafts were evaluated by hemocompatibility studies and a preliminary in vivo carotid rabbit model. The dip-spinning-SBS technology generates constructs with native mechanical properties and cell-derived biological activities, critical for clinical bypass applications.

1 February 2012 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
CGClaudio Garcia-Herrera
Claudio Garcia-Herrera
DCDiego J. Celentano
Diego J. Celentano
MCMarcela Cruchaga
Marcela Cruchaga
FPFRANCISCO JAVIER ROJO PEREZ
FRANCISCO JAVIER ROJO PEREZ
JAJosé Miguel Atienza
José Miguel Atienza
JGJose M. Goicolea
Jose M. Goicolea
This work presents experiments and modelling aimed at characterising the passive mechanical behaviour of the human thoracic descending aorta. To this end, uniaxial tension and pressurisation tests on healthy samples corresponding to newborn, young and adult arteries are performed. Then, the tensile measurements are used to calibrate the material parameters of the Holzapfel constitutive model. This model is found to adequately adjust the material behaviour in a wide deformation range; in particular, it captures the progressive stiffness increase and the anisotropy due to the stretching of the collagen fibres. Finally, the assessment of these material parameters in the modelling of the pressurisation test is addressed. The implication of this study is the possibility to predict the mechanical response of the human thoracic descending aorta under generalised loading states like those that can occur in physiological conditions and/or in medical device applications.

1 October 2017 in Construction and Building Materials
Verified
Journal Article
Closed access
Gerardo Araya-LetelierGerardo Araya-Letelier
Gerardo Araya-Letelier
FAFederico Antico
Federico Antico
Miguel CarrascoMiguel Carrasco
Miguel Carrasco
Paula RojasPaula Rojas
Paula Rojas
CGClaudio Garcia-Herrera
Claudio Garcia-Herrera

1 October 2019 in Applied Thermal Engineering
Verified
Journal Article
Closed access
VMVíctor A. Martínez
Víctor A. Martínez
Diego Andrés Andrés Vasco CalleDiego Andrés Andrés Vasco Calle
Diego Andrés Andrés Vasco Calle
CGClaudio Garcia-Herrera
Claudio Garcia-Herrera
RORoberto Ortega-Aguilera
Roberto Ortega-Aguilera

21 February 2023 in Polymers
Verified
Journal Article
Open access
PDF file
AGAldo Guzmán-Soria
Aldo Guzmán-Soria
VMViviana Moreno-Serna
Viviana Moreno-Serna
DCDaniel A. Canales
Daniel A. Canales
CGClaudio Garcia-Herrera
Claudio Garcia-Herrera
PZPaula Zapata
Paula Zapata
POPedro Orihuela
Pedro Orihuela
The development of scaffolding obtained by electrospinning is widely used in tissue engineering due to porous and fibrous structures that can mimic the extracellular matrix. In this study, poly (lactic-co-glycolic acid) (PLGA)/collagen fibers were fabricated by electrospinning method and then evaluated in the cell adhesion and viability of human cervical carcinoma HeLa and NIH-3T3 fibroblast for potential application in tissue regeneration. Additionally, collagen release was assessed in NIH-3T3 fibroblasts. The fibrillar morphology of PLGA/collagen fibers was verified by scanning electron microscopy. The fiber diameter decreased in the fibers (PLGA/collagen) up to 0.6 µm. FT-IR spectroscopy and thermal analysis confirmed that both the electrospinning process and the blend with PLGA give structural stability to collagen. Incorporating collagen in the PLGA matrix promotes an increase in the material’s rigidity, showing an increase in the elastic modulus (38%) and tensile strength (70%) compared to pure PLGA. PLGA and PLGA/collagen fibers were found to provide a suitable environment for the adhesion and growth of HeLa and NIH-3T3 cell lines as well as stimulate collagen release. We conclude that these scaffolds could be very effective as biocompatible materials for extracellular matrix regeneration, suggesting their potential applications in tissue bioengineering.