Primavera Sousa-Santos

Dr. Primavera Sousa-Santos

University Institute of Health Sciences-CESPU, Gandra, Portugal
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2009
Verified
Journal Article
Closed access
TVT Vale
T Vale
PSPrimavera Sousa-Santos
Primavera Sousa-Santos
JMJ Moreira
J Moreira
MMM C Manzanares
M C Manzanares
JUJ M Ustrell
J M Ustrell

27 June 2024 in Materials
Verified
Journal Article
Open access
PDF file
CSCatarina Sousa Dos Santos
Catarina Sousa Dos Santos
SSSofia Sousa Santos
Sofia Sousa Santos
Joana Silva MendesJoana Silva Mendes
Joana Silva Mendes
CCCarlos Leal Coelho
Carlos Leal Coelho
Carlos ArosoCarlos Aroso
Carlos Aroso
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Orthodontic Mini-Implants have a high success rate, but it is crucial to assess the load that they bear in order to maintain their primary stability. Increasing the diameter can improve this stability, but there are limitations due to the proximity of the tooth roots. To avoid damage, smaller diameters are used, which can decrease resistance and cause permanent deformations. Objective: The objective of this study is to evaluate the influence of the diameter of Mini-Implants through bending force tests, taking into account primary stability after one and two insertions. Methods: Here, 40 Ti6AI4V alloy Mini-Implants of two different brands and diameters were divided into eight groups, half of which received one insertion in the artificial bone, and the rest received two. All were subjected to a constant bending force using an INSTRON-Electropuls E10000LT (Norwood, MA, USA) until fracture. Results: The smaller-diameter Mini-Implants were less resistant to fracture, but both were able to withstand the necessary loads produced by orthodontic movements. As for the inserts, there were no statistically significant differences. Conclusions: There is an advantage to using 1.6 mm Mini-Implants over 2.0 mm ones, as a smaller diameter does not lead to fracture due to the forces used in orthodontic treatment. Having one or two inserts did not have a statistically significant effect.

Verified
Journal Article
Open access
PDF file
SSSofia Sousa-Santos
Sofia Sousa-Santos
António Sérgio SilvaAntónio Sérgio Silva
António Sérgio Silva
PSPrimavera Sousa-Santos
Primavera Sousa-Santos
TVTeresa Vale
Teresa Vale
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Temporary restorations play a fundamental role in oral rehabilitation. A properly adapted implant-supported provisional restoration implies better esthetics, contouring and architectural modeling of the upper peri-implant tissue. This study aimed to evaluate the influence of oral pH on the fracture resistance of implant-supported provisional restorations made with two brands of bis-acrylic resin (LuxaCrown® and Protemp™ 4) and to compare the fracture resistance of these two materials. Twenty crowns (ten manufactured using each brand) served as a control, and another forty crowns (twenty of each brand) were aged using artificial saliva with pHs of 4 or 7, for 7 days at 37 °C, in an attempt to simulate the behavior of these materials inside the oral cavity. Subsequently, all crowns were subjected to the application of a force at a constant speed, in a universal testing machine, until fracture was achieved. The LuxaCrown® brand showed greater resistance to fracture than the Protemp™ 4 brand. Salivary pH did not influence the fracture resistance of provisional LuxaCrown® crowns but did influence the fracture resistance of provisional Protemp™ 4 crowns.


20 May 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
PSPrimavera Sousa-Santos
Primavera Sousa-Santos
SSSofia Sousa Santos
Sofia Sousa Santos
AOAna Catarina Oliveira
Ana Catarina Oliveira
CQCíntia Queirós
Cíntia Queirós
Joana Silva MendesJoana Silva Mendes
Joana Silva Mendes
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Orthodontic mini-implants (MIs) are excellent alternative skeletal anchorage devices. Their stability is important for their survival, requiring appropriate torque application during insertion and removal. Objective: This study aimed to evaluate the influences of the diameter and brand of MIs on their stability by measuring the maximum insertion and removal torques after they had been aged in a pH 7 artificial saliva for 4 weeks at 37 °C. Methods: Forty Ti6Al4V alloy MIs of two different brands and diameters were divided into four groups. They were placed in artificial bone blocks using the NSK® Surgic Pro coupled with a digital torque gauge (Centor Touch Star TH®) to measure the maximum insertion and removal torques. Results: After ageing, the Fatscrew (Fts) MIs were more stable when removed than the white brand (WB) MIs. The WB MIs lost stability over time, while the Fts MIs—especially the 2.0 mm ones—maintained good stability. Conclusions: The significant differences between the tested groups, especially the stability observed in the 2.0 mm Fts MIs compared to the other groups, highlight the importance of brand and diameter size in the effectiveness of MIs.

Verified
Journal Article
Open access
PDF file
JBJoão Barreto-Santos
João Barreto-Santos
PSPrimavera Sousa-Santos
Primavera Sousa-Santos
POPedro Otão
Pedro Otão
Background/Objectives: Orthodontic mini-implants have become an essential source of temporary skeletal anchorage because of their versatility, minimal invasiveness, and reduced dependence on patient compliance. However, their clinical success relies on maintaining adequate primary and secondary stability throughout orthodontic treatment. Photobiomodulation (PBM) with diode lasers has been proposed as a non-invasive adjunctive therapy capable of enhancing bone healing and remodeling, thereby improving mini-implant stability. Despite encouraging findings, the available evidence remains limited and heterogeneous. The objective was to systematically evaluate the effect of diode laser photobiomodulation on the stability of orthodontic mini-implants. Methods: A systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. The search was conducted in the PubMed, EBSCO, Scopus, and ScienceDirect databases to identify randomized clinical trials published in the last 10 years. Five randomized controlled trials involving 89 participants and 178 orthodontic mini-implants fulfilled the eligibility criteria. Mini-implant stability was assessed using objective methods, including resonance frequency analysis (ISQ) and Periotest values, while one study also evaluated insertion and removal torque. The methodological quality of the included studies was assessed using the Cochrane Risk of Bias 2 (RoB 2) tool, and the certainty of the evidence was evaluated using the GRADE approach. Results: Three of the five included studies reported improvements in orthodontic mini-implant stability following diode laser photobiomodulation, whereas two studies found no significant differences compared with the control group. Considerable heterogeneity was identified regarding laser wavelength (618–940 nm), irradiation protocols, energy parameters, timing of force application, and stability assessment methods. Most studies presented a low risk of bias, although some concerns remained regarding allocation concealment and blinding. According to the GRADE assessment, the overall certainty of the evidence was considered moderate, mainly because of inconsistency across studies and methodological heterogeneity. Conclusions: Current evidence suggests that diode laser photobiomodulation may improve the stability of orthodontic mini-implants. Nevertheless, the small number of randomized clinical trials and the substantial variability in PBM protocols and outcome assessment methods preclude definitive clinical recommendations. Future well-designed randomized controlled trials using standardized irradiation parameters and uniform stability assessment methods are required to establish evidence-based clinical protocols.