Cíntia Queirós

Dr. Cíntia Queirós


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 August 2024 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
CQCíntia Queirós
Cíntia Queirós
MGMaria dos Prazeres Silva Gonçalves
Maria dos Prazeres Silva Gonçalves
SFSofia Ferreira
Sofia Ferreira
ICInês de Castro
Inês de Castro
Rui Miguel Simões de AzevedoRui Miguel Simões de Azevedo
Rui Miguel Simões de Azevedo
Teresa PinhoTeresa Pinho
Teresa Pinho
Controlling root movement is one of the greatest challenges in orthodontic treatment with aligners, like Invisalign® aligners. Cone Beam Computed Tomography (CBCT) integration into ClinCheck®, enabling bone and root visualisation, allows a more accurate follow-up of the teeth position. This study aims to compare torque measurements of the upper central incisors with and without CBCT and relate them to the upper incisor inclination and facial biotype. In a sample of 70 teeth, torque measurements were obtained by importing images into AutoCAD® software (version 2024). The angle between the tooth’s long axis with CBCT duplicate and the tooth’s long axis without CBCT was obtained to assess the difference. Statistically significant differences between torque measurements with and without CBCT were found, as well as between these measurements and the inclination of the upper incisors. No statistically significant differences were found among the facial biotypes. The average values of 27.8° ± 3.4° and 21.5° ± 3.2° were obtained for the angle between the axes. Torque without CBCT was lower than torque with CBCT, for the same tooth. The angle between the axes had a similar mean for both teeth. CBCT integration into ClinCheck® allows for a more correct torque measurement.

20 May 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
PSPrimavera Sousa-Santos
Primavera Sousa-Santos
SSSofia Sousa Santos
Sofia Sousa Santos
AOAna Catarina Oliveira
Ana Catarina Oliveira
CQCíntia Queirós
Cíntia Queirós
Joana Silva MendesJoana Silva Mendes
Joana Silva Mendes
José Manuel MendesJosé Manuel Mendes
José Manuel Mendes
Orthodontic mini-implants (MIs) are excellent alternative skeletal anchorage devices. Their stability is important for their survival, requiring appropriate torque application during insertion and removal. Objective: This study aimed to evaluate the influences of the diameter and brand of MIs on their stability by measuring the maximum insertion and removal torques after they had been aged in a pH 7 artificial saliva for 4 weeks at 37 °C. Methods: Forty Ti6Al4V alloy MIs of two different brands and diameters were divided into four groups. They were placed in artificial bone blocks using the NSK® Surgic Pro coupled with a digital torque gauge (Centor Touch Star TH®) to measure the maximum insertion and removal torques. Results: After ageing, the Fatscrew (Fts) MIs were more stable when removed than the white brand (WB) MIs. The WB MIs lost stability over time, while the Fts MIs—especially the 2.0 mm ones—maintained good stability. Conclusions: The significant differences between the tested groups, especially the stability observed in the 2.0 mm Fts MIs compared to the other groups, highlight the importance of brand and diameter size in the effectiveness of MIs.