Emiliano Martínez-Periñán

Dr. Emiliano Martínez-Periñán

Universidad Autónoma de Madrid
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2017 in Advanced Energy Materials
Verified
Journal Article
Closed access
PDF file
EMEmiliano Martínez-Periñán
Emiliano Martínez-Periñán
MDMichael P. Down
Michael P. Down
CGCarlos Gibaja
Carlos Gibaja
ELEncarnación Lorenzo
Encarnación Lorenzo
FELIX JUAN ZamoraFELIX JUAN Zamora
FELIX JUAN Zamora
Craig BanksCraig Banks
Craig Banks

21 December 2019 in Chemical Communications
Verified
Journal Article
Closed access
PDF file
SRSergio Royuela
Sergio Royuela
EMEmiliano Martínez-Periñán
Emiliano Martínez-Periñán
Marina P ArrietaMarina P Arrieta
Marina P Arrieta
JMJosé I. Martínez
José I. Martínez
MRM. Mar Ramos
M. Mar Ramos
JSJose L. Segura
Jose L. Segura
A novel naphthalene diimide-based covalent organic framework (NDI-COF) has been synthesized and successfully exfoliated into COF nanosheets (CONs) to provide an efficient electrocatalyst for the oxygen reduction reaction.

1 April 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
VSVerónica Serafín
Verónica Serafín
AVAlejandro Valverde
Alejandro Valverde
GMGonzalo Martínez-García
Gonzalo Martínez-García
EMEmiliano Martínez-Periñán
Emiliano Martínez-Periñán
FCF. Comba
F. Comba
JPJ.M. Pingarrón
J.M. Pingarrón

9 September 2020 in Biosensors
Verified
Journal Article
Open access
PDF file
EMEmiliano Martínez-Periñán
Emiliano Martínez-Periñán
CGCristina Gutiérrez-Sánchez
Cristina Gutiérrez-Sánchez
TGTania García-Mendiola
Tania García-Mendiola
Encarnacion LorenzoEncarnacion Lorenzo
Encarnacion Lorenzo
Electrogenerated chemiluminescence (also called electrochemiluminescence (ECL)) has become a great focus of attention in different fields of analysis, mainly as a consequence of the potential remarkably high sensitivity and wide dynamic range. In the particular case of sensing applications, ECL biosensor unites the benefits of the high selectivity of biological recognition elements and the high sensitivity of ECL analysis methods. Hence, it is a powerful analytical device for sensitive detection of different analytes of interest in medical prognosis and diagnosis, food control and environment. These wide range of applications are increased by the introduction of screen-printed electrodes (SPEs). Disposable SPE-based biosensors cover the need to perform in-situ measurements with portable devices quickly and accurately. In this review, we sum up the latest biosensing applications and current progress on ECL bioanalysis combined with disposable SPEs in the field of bio affinity ECL sensors including immunosensors, DNA analysis and catalytic ECL sensors. Furthermore, the integration of nanomaterials with particular physical and chemical properties in the ECL biosensing systems has improved tremendously their sensitivity and overall performance, being one of the most appropriates research fields for the development of highly sensitive ECL biosensor devices.

23 June 2022 in Sensors
Verified
Journal Article
Open access
PDF file
EMEmiliano Martínez-Periñán
Emiliano Martínez-Periñán
MFMarcos Martínez Fernández
Marcos Martínez Fernández
JSJose L. Segura
Jose L. Segura
Encarnacion LorenzoEncarnacion Lorenzo
Encarnacion Lorenzo
Covalent organic frameworks (COFs) are defined as crystalline organic polymers with programmable topological architectures using properly predesigned building blocks precursors. Since the development of the first COF in 2005, many works are emerging using this kind of material for different applications, such as the development of electrochemical sensors and biosensors. COF shows superb characteristics, such as tuneable pore size and structure, permanent porosity, high surface area, thermal stability, and low density. Apart from these special properties, COF’s electrochemical behaviour can be modulated using electroactive building blocks. Furthermore, the great variety of functional groups that can be inserted in their structures makes them interesting materials to be conjugated with biological recognition elements, such as antibodies, enzymes, DNA probe, aptamer, etc. Moreover, the possibility of linking them with other special nanomaterials opens a wide range of possibilities to develop new electrochemical sensors and biosensors.

10 February 2019 in Advanced Energy Materials
Verified
Journal Article
Open access
PDF file
MDMichael P. Down
Michael P. Down
EMEmiliano Martínez-Periñán
Emiliano Martínez-Periñán
CFChristopher W. Foster
Christopher W. Foster
ELEncarnación Lorenzo
Encarnación Lorenzo
GSG. C. Smith
G. C. Smith
Craig BanksCraig Banks
Craig Banks
The first entirely AM/3D‐printed sodium‐ion (full‐cell) battery is reported herein, presenting a paradigm shift in the design and prototyping of energy‐storage architectures. AM/3D‐printing compatible composite materials are developed for the first time, integrating the active materials NaMnO2 and TiO2 within a porous supporting material, before being AM/3D‐printed into a proof‐of‐concept model based upon the basic geometry of commercially existing AA battery designs. The freestanding and completely AM/3D‐fabricated device demonstrates a respectable performance of 84.3 mAh g−1 with a current density of 8.43 mA g−1; note that the structure is typically comprised of 80% thermoplastic, but yet, still works and functions as an energy‐storage platform. The AM/3D‐fabricated device is critically benchmarked against a battery developed using the same active materials, but fabricated via a traditional manufacturing method utilizing an ink‐based/doctor‐bladed methodology, which is found to exhibit a specific capacity of 98.9 mAh m−2 (116.35 mAh g−1). The fabrication of fully AM/3D‐printed energy‐storage architectures compares favorably with traditional approaches, with the former providing a new direction in battery manufacturing. This work represents a paradigm shift in the technological and design considerations in battery and energy‐storage architectures.