Electrochemical immunosensors are antibody-based affinity biosensors with a high impact on clinical, environmental, food, and pharmaceutical analysis. In general, the analytical performance of these devices is critically determined by the materials and reagents used for their construction, signal production and amplification. Dendrimers are monodisperse and highly branched polymers with three-dimensional structures widely employed as “soft” nanomaterials in electrochemical immunosensor technology. This review provides an overview on the state-of-the-art in dendrimer-based electrochemical immunosensors, focusing on those using polyamidoamine and poly (propylene imine) dendrimers. Special emphasis is given to the most original methods recently reported for the construction of immunosensor architectures incorporating dendrimers, as well as to novel sensing approaches based on dendrimer-assisted signal enhancement strategies.
A biosensor for 3-hydroxybutyrate (3-HB) involving immobilization of the enzyme 3-hydroxybutyrate dehydrogenase onto a screen-printed carbon electrode modified with reduced graphene oxide (GO) and thionine (THI) is reported here. After addition of 3-hydroxybutyrate or the sample in the presence of NAD+ cofactor, the generated NADH could be detected amperometrically at 0.0 V vs. Ag pseudo reference electrode. Under the optimized experimental conditions, a calibration plot for 3-HB was constructed showing a wide linear range between 0.010 and 0.400 mM 3-HB which covers the clinically relevant levels for diluted serum samples. In addition, a limit of detection of 1.0 µM, much lower than that reported using other biosensors, was achieved. The analytical usefulness of the developed biosensor was demonstrated via application to spiked serum samples.
This paper reports a dual electrochemical biosensor involving carboxylated- or neutravidin-functionalized magnetic microbeads and dual screen-printed carbon electrodes for the simultaneous determination of rheumatoid factor (RF) and anti-cyclic citrullinated peptide (CCPA) autoantibodies used as biomarkers for the detection of rheumatoid arthritis autoimmune disease. Sandwich-type biosensors involving Fc fragments of IgG Fc(IgG) and biotinylated cyclic cytrullinated peptide (CCP-biotin) to form CCP-biotin-Neutr-MBs for the specific immobilization of RF and CCPA, respectively, as well as conjugation with HRP-IgM and HRP-IgG for RF and CCPA, respectively, were prepared. Amperometric detection was performed at −0.20 V vs. Ag pseudo-reference electrode using the H2O2/hydroquinone (HQ) system upon capturing the bioconjugates onto the corresponding working electrode (WE1 or WE2) of SPCdEs. The dual biosensor exhibits high sensitivity for RF and CCPA with LOD values of 0.8 and 2.5 IU mL−1, respectively. The simultaneous determination can be completed in about two hours using a simple protocol and a sample volume (25 μL) four times smaller than that required by the ELISA method. The dual electrochemical biosensor was used for the determination of both target biomarkers in human serum.