In silico studies have provided robust evidence that stent design affects local haemodynamic forces, which appear as a major determinant of clinical outcomes following stent implantation. However, the implications of different stent/scaffold configurations on local haemodynamic forces have not yet been investigated in vivo in a comparative fashion. The aim of this study was to compare the ESS distribution in two differently shaped scaffolds using OCT-based modelling. Eight healthy mini pigs were implanted with six Absorb everolimus-eluting bioresorbable vascular scaffolds (Absorb BVS) and five Mirage sirolimus-eluting bioresorbable microfibre scaffolds (Mirage BRMS). Optical coherence tomography (OCT) was performed and strut protrusion was assessed post scaffold implantation. Following the reconstruction of coronary anatomy, blood flow simulation was performed and endothelial shear stress (ESS) was estimated on top of the struts and at luminal surface between the struts in each scaffold. The thicker struts in Absorb (152±140 μm) resulted in an increased protruded distance compared to Mirage (117±123 μm) (p=0.003). This had an effect on the local haemodynamic microenvironment. ESS at the top of the struts was higher in Absorb (1.69±1.20 Pa) than in Mirage (1.53±0.91 Pa) (p<0.001), but lower at inter-strut zones (0.60±0.51 Pa vs. 0.63±0.50 Pa; p<0.01) compared to Mirage. Both scaffold types revealed comparable percentages of vessel luminal surface exposed to recirculation. Absorb demonstrated higher shear stress on top of the struts compared to Mirage. However, in the inter-strut zones shear stress was higher in Mirage than in Absorb. Further research is required to examine the potential value of in vivo computational modelling in optimising scaffold configuration and clinical outcomes.
Background Rapid triage of patients presenting with chest pain is essential for early diagnosis and safe disposition. The European Society of Cardiology (ESC) 0/1-hour hs-cTn algorithm has shown promising performance in Western cohorts, but evidence supporting its implementation in diverse Asian emergency department (ED) settings remains limited. Therefore, we evaluated the safety and clinical utility of the ESC 0/1-hour algorithm for chest pain triage across multiple Asian EDs. Methods This was a prospective, stepped-wedge, cluster-randomised trial conducted across 12 hospitals in five Asian countries, enrolling 3869 patients with suspected acute coronary syndrome without ST elevation (NSTE-ACS). Usual care involved troponin testing without standardised timing, whereas the 0/1-hour protocol followed ESC recommendations using high-sensitivity cardiac troponin T testing at baseline and 1 hour. The primary endpoint was 30-day major adverse cardiac events (MACE), including cardiovascular death, myocardial infarction (MI) and unplanned revascularisation. Non-inferiority was assessed using a one-sided 95% CI with a margin of 1.5%. Results Of 3869 patients (2059 usual care; 1810 0/1-hour care), MACE occurred in 1.7% of usual care patients and 1.4% in the 0/1-hour care (upper one-sided 95% CI –0.3%), confirming non-inferiority. ED discharge rates were significantly higher with the 0/1-hour algorithm (60% vs 35%, p<0.001). Among 941 patients classified as low risk group, MACE occurred in only 3 patients, including one cardiovascular death and two unplanned revascularisations; no non-fatal MIs were reported. Conclusion The ESC 0/1-hour algorithm is safe and effective for rapid triage of chest pain in Asian EDs. These findings provide external validation of the 0/1-hour algorithm and support broader global implementation. Trial registration number UMIN000042461.
8 November 2021 in European Heart Journal - Case Reports
Background: IgG4-related disease (IgG4-RD) is a chronic fibroinflammatory condition with multiple-organ involvement. Rupture of coronary artery aneurysms (CAAs) in IgG4-RD is rare. Case summary: A 65-year-old man with IgG4-RD has suffered from recurrent episodes of arterial aneurysms since 2003. He presented with chest pain and hypotension caused by localized cardiac tamponade at right ventricle free wall due to the rupture of coronary artery aneurysm (CAA) of left anterior descending artery (LAD). An urgent LAD aneurysm repaired with bovine pericardium and obliterated aneurysmal sac with cryo-acrylate glue was done together with coronary artery bypass grafting (CABG) using saphenous vein graft (SVG) to LAD and SVG to posterior descending artery. Three-month after surgery, the follow-up coronary computed tomography angiography (CCTA) revealed a growing in size of LAD and the second obtuse marginal (OM) branch aneurysm. Heart team discussion agreed to schedule the patient for double coil embolization to LAD and second OM aneurysm under intravascular ultrasound guidance. Both aneurysms were successfully obliterated with vascular coils. Two-week follow-up coronary angiogram showed complete occlusion of LAD aneurysm and near occlusion of the second OM branch aneurysm. Discussion: Coronary artery aneurysm rupture is a life-threatening condition that required prompt detection and treatments. In IgG4-RD patients, acute cardiac tamponade suggesting the rupture of CAA. Coil embolization is an alternative treatment in patients who suffered from recurrent CAA after surgical repair. Serial CCTA is important for early detection of aneurysm in IgG4-RD patients who had vascular involvement.