ERHAN TENEKECIOGLU

Prof. ERHAN TENEKECIOGLU

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 April 2016 in European Heart Journal
Verified
Journal Article
Open access
PDF file
CBChristos V. Bourantas
Christos V. Bourantas
FJFarouc A. Jaffer
Farouc A. Jaffer
FGFrank J. Gijsen
Frank J. Gijsen
GSGijs van Soest
Gijs van Soest
SMSean P. Madden
Sean P. Madden
PSPatrick Serruys
Patrick Serruys
Cumulative evidence from histology-based studies demonstrate that the currently available intravascular imaging techniques have fundamental limitations that do not allow complete and detailed evaluation of plaque morphology and pathobiology, limiting the ability to accurately identify high-risk plaques. To overcome these drawbacks, new efforts are developing for data fusion methodologies and the design of hybrid, dual-probe catheters to enable accurate assessment of plaque characteristics, and reliable identification of high-risk lesions. Today several dual-probe catheters have been introduced including combined near infrared spectroscopy-intravascular ultrasound (NIRS-IVUS), that is already commercially available, IVUS-optical coherence tomography (OCT), the OCT-NIRS, the OCT-near infrared fluorescence (NIRF) molecular imaging, IVUS-NIRF, IVUS intravascular photoacoustic imaging and combined fluorescence lifetime-IVUS imaging. These multimodal approaches appear able to overcome limitations of standalone imaging and provide comprehensive visualization of plaque composition and plaque biology. The aim of this review article is to summarize the advances in hybrid intravascular imaging, discuss the technical challenges that should be addressed in order to have a use in the clinical arena, and present the evidence from their first applications aiming to highlight their potential value in the study of atherosclerosis.

20 August 2018 in European Heart Journal
Verified
Journal Article
Closed access
CCCarlos Collet
Carlos Collet
YOYoshinobu Onuma
Yoshinobu Onuma
JSJeroen Sonck
Jeroen Sonck
TATaku Asano
Taku Asano
BVBert Vandeloo
Bert Vandeloo
PSPatrick W Serruys
Patrick W Serruys
Pressure-wire assessment of coronary stenosis is considered the invasive reference standard for detection of ischaemia-generating lesions. Recently, methods to estimate the fractional flow reserve (FFR) from conventional angiography without the use of a pressure wire have been developed, and were shown to have an excellent diagnostic accuracy. The present systematic review and meta-analysis aimed at determining the diagnostic performance of angiography-derived FFR for the diagnosis of haemodynamically significant coronary artery disease. A systematic review and meta-analysis of studies assessing the diagnostic performance of angiography-derived FFR systems were performed. The primary outcome of interest was pooled sensitivity and specificity. Thirteen studies comprising 1842 vessels were included in the final analysis. A Bayesian bivariate meta-analysis yielded a pooled sensitivity of 89% (95% credible interval 83-94%), specificity of 90% (95% credible interval 88-92%), positive likelihood ratio (+LR) of 9.3 (95% credible interval 7.3-11.7) and negative likelihood ratio (-LR) of 0.13 (95% credible interval 0.07-0.2). The summary area under the receiver-operating curve was 0.84 (95% credible interval 0.66-0.94). Meta-regression analysis did not find differences between the methods for pressure-drop calculation (computational fluid dynamics vs. mathematical formula), type of analysis (on-line vs. off-line) or software packages. The accuracy of angiography-derived FFR was good to detect haemodynamically significant lesions with pressure-wire measured FFR as a reference. Computational approaches and software packages did not influence the diagnostic accuracy of angiography-derived FFR. A diagnostic strategy trial with angiography-derived FFR evaluating clinical endpoints is warranted.

14 April 2017 in Circulation Research
Verified
Journal Article
Closed access
YSYohei Sotomi
Yohei Sotomi
YOYoshinobu Onuma
Yoshinobu Onuma
CCCarlos Collet
Carlos Collet
ETERHAN TENEKECIOGLU
ERHAN TENEKECIOGLU
RVRenu Virmani
Renu Virmani
PSPatrick Serruys
Patrick Serruys
In the era of drug-eluting stents, large-scale randomized trials and all-comer registries have shown excellent clinical results. However, even the latest-generation drug-eluting stent has not managed to address all the limitations of permanent metallic coronary stents, such as the risks of target lesion revascularization, neoatherosclerosis, preclusion of late lumen enlargement, and the lack of reactive vasomotion. Furthermore, the risk of very late stent, although substantially reduced with newer-generation drug-eluting stent, still remains. These problems were anticipated to be solved with the advent of fully biodegradable devices. Fully bioresorbable coronary scaffolds have been designed to function transiently to prevent acute recoil, but have retained the capability to inhibit neointimal proliferation by eluting immunosuppressive drugs. Nevertheless, long-term follow-up data of the leading bioresorbable scaffold (Absorb) are becoming available and have raised a concern about the relatively higher incidence of scaffold thrombosis. To reduce the rate of clinical events, improvements in the device, as well as implantation procedure, are being evaluated. This review will focus on the current CE-mark approved bioresorbable scaffolds, their basic characteristics, and clinical results. In addition, we summarize the current limitations of bioresorbable scaffold and their possible solutions.

1 December 2017 in Arteriosclerosis, Thrombosis, and Vascular Biology
Verified
Journal Article
Closed access
JNJaryl Ng
Jaryl Ng
CBChristos V. Bourantas
Christos V. Bourantas
RTRyo Torii
Ryo Torii
HAHui Ying Ang
Hui Ying Ang
ETERHAN TENEKECIOGLU
ERHAN TENEKECIOGLU
NFNicolas Foin
Nicolas Foin
Local hemodynamic forces are well-known to modulate atherosclerotic evolution, which remains one of the largest cause of death worldwide. Percutaneous coronary interventions with stent implantation restores blood flow to the downstream myocardium and is only limited by stent failure caused by restenosis, stent thrombosis, or neoatherosclerosis. Cumulative evidence has shown that local hemodynamic forces affect restenosis and the platelet activation process, modulating the pathophysiological mechanisms that lead to stent failure. This article first covers the pathophysiological mechanisms through which wall shear stress regulates arterial disease formation/neointima proliferation and the role of shear rate on stent thrombosis. Subsequently, the article reviews the current evidence on (1) the implications of stent design on the local hemodynamic forces, and (2) how stent/scaffold expansion can influence local flow, thereby affecting the risk of adverse events.

1 June 2018 in JACC
Verified
Journal Article
Closed access
CCCarlos Collet
Carlos Collet
YMYosuke Miyazaki
Yosuke Miyazaki
NRNicola Ryan
Nicola Ryan
TATaku Asano
Taku Asano
ETERHAN TENEKECIOGLU
ERHAN TENEKECIOGLU
PSPatrick Serruys
Patrick Serruys

1 July 2017 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
JAJung-Min Ahn
Jung-Min Ahn
DPDuk-Woo Park
Duk-Woo Park
CLCheol Whan Lee
Cheol Whan Lee
MCMineok Chang
Mineok Chang
RCRafael Cavalcante
Rafael Cavalcante
SPSeung-Jung Park
Seung-Jung Park