Joske van der Zande

Ms. Joske van der Zande

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JZJoske van der Zande
Joske van der Zande
MSMarc Strik
Marc Strik
RDRemi Dubois
Remi Dubois
SPSylvain Ploux
Sylvain Ploux
SASaer Abu-Alrub
Saer Abu-Alrub
PBPierre Bordachar
Pierre Bordachar
Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain conventional frontal and precordial leads as compared to standard 12-lead ECGs in both subjects without known cardiac anomalies and patients with underlying heart disease. In 200 subjects (67% with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST, and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland–Altman analysis, including the bias, absolute offset, and 95% limits of agreement. AW-ECGs recorded on the wrist but also beyond the wrist had similar durations and amplitudes compared to standard 12-lead ECGs. Significantly greater amplitudes were measured by the AW for R-waves in precordial leads V1, V3, and V6 (+0.094 mV, +0.149 mV, +0.129 mV, respectively, all p < 0.001), indicating a positive bias for the AW. AW can be used to record frontal, and precordial ECG leads, paving the way for broader clinical applications.

1 September 2025 in European Heart Journal
Verified
Journal Article
Open access
RVRick Volleberg
Rick Volleberg
TLThijs J Luttikholt
Thijs J Luttikholt
RWRuben van der Waerden
Ruben van der Waerden
PCPierandrea Cancian
Pierandrea Cancian
JZJoske van der Zande
Joske van der Zande
NRNiels Van Royen
Niels Van Royen
Background and Aims: Coronary thin-cap fibroatheromas (TCFA) are associated with adverse outcome, but identification of TCFA requires expertise and is highly time-demanding. This study evaluated the utility of artificial intelligence (AI) for TCFA identification in relation to clinical outcome. Methods: The PECTUS-AI study is a secondary analysis from the prospective observational PECTUS-obs study, in which 438 patients with myocardial infarction underwent optical coherence tomography (OCT) of all fractional flow reserve-negative non-culprit lesions (i.e. target lesions). OCT images were analyzed for the presence of TCFA by an independent core laboratory (CL-TCFA) and OCT-AID, a recently developed and validated AI segmentation algorithm (AI-TCFA). The primary outcome was defined as the composite of death from any cause, non-fatal myocardial infarction or unplanned revascularisation at 2 years (±30 days), excluding procedural and stent-related events. Results: Among 414 patients, AI-TCFA and CL-TCFA were identified in 143 (34.5%) and 124 (30.0%) patients, respectively. AI-TCFA within the target lesion was significantly associated with the primary outcome [hazard ratio (HR) 1.99, 95% confidence interval (CI) 1.02–3.90, P = .04], while the HR for CL-TCFA was non-significant (1.67, 95% CI: .84–3.30, P = .14). When evaluating the complete pullback, AI-TCFA showed an even stronger association with the primary outcome (HR 5.50, 95% CI: 1.94–15.62, P < .001; negative predictive value 97.6%, 95% CI: 94.0%–99.3%). Conclusions: AI-based OCT image analysis allows standardized identification of patients at increased risk of adverse cardiovascular outcome, offering an alternative to manual image analysis. Furthermore, AI-assisted evaluation of complete imaged segments results in better prognostic discrimatory value than evaluation of the target lesion only.

28 January 2025 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
RWRuben van der Waerden
Ruben van der Waerden
RVRick Volleberg
Rick Volleberg
TLThijs J Luttikholt
Thijs J Luttikholt
PCPierandrea Cancian
Pierandrea Cancian
JZJoske van der Zande
Joske van der Zande
JTJos Thannhauser
Jos Thannhauser
Intracoronary optical coherence tomography (OCT) is a valuable tool for, among others, periprocedural guidance of percutaneous coronary revascularization and the assessment of stent failure. However, manual OCT image interpretation is challenging and time-consuming, which limits widespread clinical adoption. Automated analysis of OCT frames using artificial intelligence (AI) offers a potential solution. For example, AI can be employed for automated OCT image interpretation, plaque quantification, and clinical event prediction. Many AI models for these purposes have been proposed in recent years. However, these models have not been systematically evaluated in terms of model characteristics, performances, and bias. We performed a systematic review of AI models developed for OCT analysis to evaluate the trends and performances, including a systematic evaluation of potential sources of bias in model development and evaluation.

15 March 2025 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
RVRick Volleberg
Rick Volleberg
RWRuben van der Waerden
Ruben van der Waerden
TLThijs J Luttikholt
Thijs J Luttikholt
JZJoske van der Zande
Joske van der Zande
PCPierandrea Cancian
Pierandrea Cancian
NRNiels Van Royen
Niels Van Royen
Aims: Intracoronary optical coherence tomography (OCT) provides detailed information on coronary lesions, but interpretation of OCT images is time-consuming and subject to interobserver variability. The aim of this study was to develop and validate a deep learning-based multiclass semantic segmentation algorithm for OCT (OCT-AID). Methods and results: A reference standard was obtained through manual multiclass annotation (guidewire artefact, lumen, side branch, intima, media, lipid plaque, calcified plaque, thrombus, plaque rupture, and background) of OCT images from a representative subset of pullbacks from the PECTUS-obs study. Pullbacks were randomly divided into a training and internal test set. An additional independent dataset was used for external testing. In total, 2808 frames were used for training and 218 for internal testing. The external test set comprised 392 frames. On the internal test set, the mean Dice score across nine classes was 0.659 overall and 0.757 on the true-positive frames, ranging from 0.281 to 0.989 per class. Substantial to almost perfect agreement was achieved for frame-wise identification of both lipid (κ=0.817, 95% CI 0.743–0.891) and calcified plaques (κ=0.795, 95% CI 0.703–0.887). For plaque quantification (e.g. lipid arc, calcium thickness), intraclass correlations of 0.664–0.884 were achieved. In the external test set, κ-values for lipid and calcified plaques were 0.720 (95% CI 0.640–0.800) and 0.851 (95% CI 0.794–0.908), respectively. Conclusion: The developed multiclass semantic segmentation method for intracoronary OCT images demonstrated promising capabilities for various classes, while having included difficult frames, such as those containing artefacts or destabilized plaques. This algorithm is an important step towards comprehensive and standardized OCT image interpretation.

15 January 2024 in Sensors
Verified
Journal Article
Open access
PDF file
MSMarc Strik
Marc Strik
SPSylvain Ploux
Sylvain Ploux
JZJoske van der Zande
Joske van der Zande
Anouk VelraedsAnouk Velraeds
Anouk Velraeds
LFLeslie FONTAGNE-CHASSAING
Leslie FONTAGNE-CHASSAING
PBPierre Bordachar
Pierre Bordachar
Unlimited access to ECGs using an over-the-counter smartwatch constitutes a real revolution for our discipline, and the application is rapidly expanding to include patients with cardiac implantable electronic devices (CIEDs) such as pacemakers (PMs) and implantable cardioverter defibrillators (ICDs). CIEDs require periodic evaluation and adjustment by healthcare professionals. In addition, implanted patients often present with symptoms that may be related to their PMs or ICDs. An ECG smartwatch could reveal information about device functioning, confirm normal device function, or aid in the case of device troubleshooting. In this review, we delve into the available evidence surrounding smartwatches with ECG registration and their integration into the care of patients with implanted pacemakers and ICDs. We explore safety considerations and the benefits and limitations associated with these wearables, drawing on relevant studies and case series from our own experience. By analyzing the current landscape of this emerging technology, we aim to provide a comprehensive overview that facilitates informed decision-making for both healthcare professionals and patients.

20 November 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Anouk VelraedsAnouk Velraeds
Anouk Velraeds
MSMarc Strik
Marc Strik
JZJoske van der Zande
Joske van der Zande
LFLeslie FONTAGNE-CHASSAING
Leslie FONTAGNE-CHASSAING
MHMichel Haïssaguerre
Michel Haïssaguerre
PBPierre Bordachar
Pierre Bordachar
Smartwatches equipped with automatic atrial fibrillation (AF) detection through electrocardiogram (ECG) recording are increasingly prevalent. We have recently reported the limitations of the Apple Watch (AW) in correctly diagnosing AF. In this study, we aim to apply a data science approach to a large dataset of smartwatch ECGs in order to deliver an improved algorithm. We included 723 patients (579 patients for algorithm development and 144 patients for validation) who underwent ECG recording with an AW and a 12-lead ECG (21% had AF and 24% had no ECG abnormalities). Similar to the existing algorithm, we first screened for AF by detecting irregularities in ventricular intervals. However, as opposed to the existing algorithm, we included all ECGs (not applying quality or heart rate exclusion criteria) but we excluded ECGs in which we identified regular patterns within the irregular rhythms by screening for interval clusters. This “irregularly irregular” approach resulted in a significant improvement in accuracy compared to the existing AW algorithm (sensitivity of 90% versus 83%, specificity of 92% versus 79%, p < 0.01). Identifying regularity within irregular rhythms is an accurate yet inclusive method to detect AF using a smartwatch ECG.