Thijs J. Luttikholt

Thijs J. Luttikholt

Auto-generated profile, based on publicly available information

Thijs J. Luttikholt

Radboud University Medical Center

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in European Heart Journal
Verified
Journal Article
Open access
RVRick Volleberg
Rick Volleberg
TLThijs J Luttikholt
Thijs J Luttikholt
RWRuben van der Waerden
Ruben van der Waerden
PCPierandrea Cancian
Pierandrea Cancian
JZJoske van der Zande
Joske van der Zande
NRNiels Van Royen
Niels Van Royen
Background and Aims: Coronary thin-cap fibroatheromas (TCFA) are associated with adverse outcome, but identification of TCFA requires expertise and is highly time-demanding. This study evaluated the utility of artificial intelligence (AI) for TCFA identification in relation to clinical outcome. Methods: The PECTUS-AI study is a secondary analysis from the prospective observational PECTUS-obs study, in which 438 patients with myocardial infarction underwent optical coherence tomography (OCT) of all fractional flow reserve-negative non-culprit lesions (i.e. target lesions). OCT images were analyzed for the presence of TCFA by an independent core laboratory (CL-TCFA) and OCT-AID, a recently developed and validated AI segmentation algorithm (AI-TCFA). The primary outcome was defined as the composite of death from any cause, non-fatal myocardial infarction or unplanned revascularisation at 2 years (±30 days), excluding procedural and stent-related events. Results: Among 414 patients, AI-TCFA and CL-TCFA were identified in 143 (34.5%) and 124 (30.0%) patients, respectively. AI-TCFA within the target lesion was significantly associated with the primary outcome [hazard ratio (HR) 1.99, 95% confidence interval (CI) 1.02–3.90, P = .04], while the HR for CL-TCFA was non-significant (1.67, 95% CI: .84–3.30, P = .14). When evaluating the complete pullback, AI-TCFA showed an even stronger association with the primary outcome (HR 5.50, 95% CI: 1.94–15.62, P < .001; negative predictive value 97.6%, 95% CI: 94.0%–99.3%). Conclusions: AI-based OCT image analysis allows standardized identification of patients at increased risk of adverse cardiovascular outcome, offering an alternative to manual image analysis. Furthermore, AI-assisted evaluation of complete imaged segments results in better prognostic discrimatory value than evaluation of the target lesion only.

28 January 2025 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
RWRuben van der Waerden
Ruben van der Waerden
RVRick Volleberg
Rick Volleberg
TLThijs J Luttikholt
Thijs J Luttikholt
PCPierandrea Cancian
Pierandrea Cancian
JZJoske van der Zande
Joske van der Zande
JTJos Thannhauser
Jos Thannhauser
Intracoronary optical coherence tomography (OCT) is a valuable tool for, among others, periprocedural guidance of percutaneous coronary revascularization and the assessment of stent failure. However, manual OCT image interpretation is challenging and time-consuming, which limits widespread clinical adoption. Automated analysis of OCT frames using artificial intelligence (AI) offers a potential solution. For example, AI can be employed for automated OCT image interpretation, plaque quantification, and clinical event prediction. Many AI models for these purposes have been proposed in recent years. However, these models have not been systematically evaluated in terms of model characteristics, performances, and bias. We performed a systematic review of AI models developed for OCT analysis to evaluate the trends and performances, including a systematic evaluation of potential sources of bias in model development and evaluation.

15 March 2025 in European Heart Journal - Digital Health
Verified
Journal Article
Open access
RVRick Volleberg
Rick Volleberg
RWRuben van der Waerden
Ruben van der Waerden
TLThijs J Luttikholt
Thijs J Luttikholt
JZJoske van der Zande
Joske van der Zande
PCPierandrea Cancian
Pierandrea Cancian
NRNiels Van Royen
Niels Van Royen
Aims: Intracoronary optical coherence tomography (OCT) provides detailed information on coronary lesions, but interpretation of OCT images is time-consuming and subject to interobserver variability. The aim of this study was to develop and validate a deep learning-based multiclass semantic segmentation algorithm for OCT (OCT-AID). Methods and results: A reference standard was obtained through manual multiclass annotation (guidewire artefact, lumen, side branch, intima, media, lipid plaque, calcified plaque, thrombus, plaque rupture, and background) of OCT images from a representative subset of pullbacks from the PECTUS-obs study. Pullbacks were randomly divided into a training and internal test set. An additional independent dataset was used for external testing. In total, 2808 frames were used for training and 218 for internal testing. The external test set comprised 392 frames. On the internal test set, the mean Dice score across nine classes was 0.659 overall and 0.757 on the true-positive frames, ranging from 0.281 to 0.989 per class. Substantial to almost perfect agreement was achieved for frame-wise identification of both lipid (κ=0.817, 95% CI 0.743–0.891) and calcified plaques (κ=0.795, 95% CI 0.703–0.887). For plaque quantification (e.g. lipid arc, calcium thickness), intraclass correlations of 0.664–0.884 were achieved. In the external test set, κ-values for lipid and calcified plaques were 0.720 (95% CI 0.640–0.800) and 0.851 (95% CI 0.794–0.908), respectively. Conclusion: The developed multiclass semantic segmentation method for intracoronary OCT images demonstrated promising capabilities for various classes, while having included difficult frames, such as those containing artefacts or destabilized plaques. This algorithm is an important step towards comprehensive and standardized OCT image interpretation.


23 September 2026 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Open access
LHLeah Heil
Leah Heil
TLThijs J. Luttikholt
Thijs J. Luttikholt
JZJoske van der Zande
Joske van der Zande
JMJan-Quinten Mol
Jan-Quinten Mol
RWRuben van der Waerden
Ruben van der Waerden
RVRick Volleberg
Rick Volleberg

6 October 2026 in Journal of the American Heart Association
Verified
Journal Article
Open access
RVRick Volleberg
Rick Volleberg
DSDoosup Shin
Doosup Shin
RWRuben van der Waerden
Ruben van der Waerden
CPCraig R. Porter
Craig R. Porter
STSusan V. Thomas
Susan V. Thomas
NRNiels Van Royen
Niels Van Royen
Background: Artificial intelligence (AI) allows automated evaluation of intracoronary optical coherence tomography (OCT) images. However, algorithms are mostly developed and validated on well‐curated data sets, which may not represent real‐world data. We sought to externally validate a previously developed algorithm performing full‐vessel segmentation for OCT in an unselected consecutive real‐world data set. Methods: This was a retrospective, single‐center, external validation study comprising 100 consecutive patients undergoing clinically indicated OCT. A previously developed AI algorithm (OCT‐AID) was used for automated pixelwise labeling of OCT images, distinguishing among lumen, guidewire artifact, intima, media, lipid plaque, calcium plaque, side branch, plaque rupture, thrombus, microvessel, and background. The AI‐based predictions were compared on a frame level to the reference standard obtained through manual OCT image analysis by expert readers. Results: Among 2560 analyzable frames, the agreement between the automated OCT image analysis and the reference standard was excellent for calcified plaque identification (κ=0.88 [95% CI, 0.84–0.92]) and quantification (intraclass correlation coefficient values ranged between 0.79 and 0.93), with a performance close to interobserver variability. For lipid plaque identification and quantification, the model performance was reasonable (κ=0.68 [95% CI, 0.64–0.72]; intraclass correlation coefficient for lipid arc, 0.79 [95% CI, 0.76–0.81]; intraclass correlation coefficient for minimum fibrous cap thickness, 0.59 [95% CI, 0.55–0.63]) and largely superior to interobserver variability. The algorithm performance for low‐prevalence features (e.g., plaque rupture) was limited. Conclusions: AI‐based fully automated evaluation of OCT images is feasible with performances consistent with interobserver variability in a real‐world data set of consecutive patients, supporting generalizability of the proposed methodology.