Akash Gupta

Mr. Akash Gupta

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
AGAkash Gupta
Akash Gupta
ABAnant Bhardwaj
Anant Bhardwaj
ABAchim Bittner
Achim Bittner
ADAlfons Dehe
Alfons Dehe
Photoacoustic spectroscopy (PAS) is a powerful technique for selective gas detection; however, its performance in non-resonant configurations is fundamentally constrained by the poor low-frequency response of conventional acoustic detectors. Commercial MEMS microphones, although compact and cost effective, exhibit limited infrasound sensitivity, which restricts the development of truly miniaturised and broadband PAS systems. To address this limitation, we present a novel MEMS fluidic microphone (f-mic) that operates on a thermal sensing principle and is explicitly optimised for the infrasound regime. The sensor demonstrates a constant sensitivity of 32 μV/Pa for frequencies below 20 Hz. A detailed analytical model incorporating frequency-dependent effects is developed to identify and investigate the critical design parameters that influence system performance. The overall system exhibits a band-pass frequency response, enabling broadband operation. Based on these insights, a miniaturised photoacoustic cell is fabricated, ensuring efficient optical coupling and f-mic integration. Experimental validation using a CO2-targeted laser system demonstrates a linear response up to 5000 ppm, a sensitivity of 6 nV/ppm, and a theoretical detection limit of 300 ppb over 100 s, resulting in an NNEA of 6×10−6 W cm−1 Hz−0.5. These results establish the f-mic as a robust, scalable solution for non-resonant PAS, effectively overcoming a significant bottleneck in compact gas sensing technologies.

9 October 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
AGAkash Gupta
Akash Gupta
ABAnant Bhardwaj
Anant Bhardwaj
ABAchim Bittner
Achim Bittner
ADAlfons Dehe
Alfons Dehe
Photoacoustic spectroscopy (PAS) is a powerful technique for selective gas detection; however, its performance in non-resonant configurations is fundamentally constrained by the poor low-frequency response of conventional acoustic detectors. Commercial MEMS microphones, although compact and cost-effective, exhibit limited infrasound sensitivity, which restricts the development of truly miniaturised and broadband PAS systems. To address this limitation, we present a novel MEMS fluidic microphone (f-mic) that operates on a thermal sensing principle and is explicitly optimised for the infrasound regime. The sensor demonstrates a constant sensitivity of 32 µV/Pa for frequencies below 20 Hz. A detailed analytical model incorporating frequency-dependent effects was developed to identify and investigate the critical design parameters that influence system performance. Based on these insights, a miniaturised photoacoustic cell was fabricated, ensuring efficient optical coupling and f-mic integration. Experimental validation using a CO2-targeted laser system demonstrates a linear response up to 5000 ppm, a sensitivity of 6 nV/ppm, and a theoretical detection limit of 300 ppb over 100 seconds, resulting in an NNEA of 6e-6 W cm^-1 Hz^-0.5. Long-term measurements indicate good stability, with minor drift primarily due to gas leakage and chopper fluctuations. These results establish the f-mic as a robust, scalable solution for non-resonant PAS, effectively overcoming a significant bottleneck in compact gas sensing technologies.

1 January 2024
Verified
Conference Paper
Open access
PDF file
AGAkash Gupta
Akash Gupta
ABA. Bittner
A. Bittner
ADA. Dehé
A. Dehé
In this work, we investigate the different internal noise mechanism affecting the performance of our MEMS based dynamic pressure sensor based on thermal anemometric principle [1]. We present sensitivity and noise measurements for two different chip designs for a comparative analysis with theoretical values. Finally, we show that the design modification resulted in the enhancement of the Signal to Noise ratio (SNR) by 30 dB and the dynamic pressure detection lower limit by a factor by 20 dBSPL.