In this work, a deep-seated negative axicon fiber tip (DSNA-FT) generating the Bessel–Gauss beam is proposed as an optical probe for a common-path optical coherence tomography (CPOCT) imaging. The axicon at the optical fiber tip is fabricated by etching the tip of a selective optical fiber in hydrofluoric acid under the influence of capillary action. The nondiffracting type quasi-Bessel beam from the DSNA-FT having a long depth of field, ∼0.7 mm, is used for the CPOCT imaging of different type of samples, i.e., sticky tape, fish scale, and rice grain. The CPOCT with unique and simple optical fiber probe has achieved lateral resolution at least ∼3.3 μm maintained up to 3 mm working distance in air. This optical fiber tip is an excellent candidate for an endoscopic probe design.
Photonic nanojet (PNJ) of subwavelength spot-size originating at shadow side of a microsphere is projected as an imperative optical tool for micro-nano optics applications. Lack of a free hold PNJ source limits its vast potential. A state-of-the-art PNJ is introduced on a chemically etched encaved optical fiber nanoprobe holding a microsphere. Nanoprobe generating optical beam of spot-size ~2 μm, is focused on the microsphere resulting in PNJ of varying spot-size, 0.8λ to 0.5λ, over its’ length ~13λ at 660 nm wavelength. A PNJ centered around 840 nm wavelength combined with an effective numerical aperture ~2 results in an en-face optical coherence tomography (OCT) image of lateral resolution ~247 nm and phase map with optical thickness, ~70 nm for a standard DVD. Further, the PNJ based backscattered nanoscopy of silver nano-particles is exhibited with resolution ~40 nm. This commercially viable PNJ head can be an ideal platform for various microscopies and other applications.
This work presents an optical fiber negative/reflective axicon probe that generates an energy-efficient quasi-Bessel beam (QBB) having a central spot (CS) possessing of the QBB power. With silver coating around the axicon, the CS power has been increased by . The QBB possesses a large depth of field, , with a micron order spot size as obtained experimentally. The probe has further been explored for common-path optical coherence tomography. The probe length has been optimized to minimize the path length difference between the reference and sample signal. With a divergence angle of just 0.013°, the beam provides a lateral resolution of to for an axial distance of 0.1 to 1.0 mm. The imaging results are presented for standard samples such as onion and Scotch tape.
In this work, a common-path optical coherence tomography (OCT) system is demonstrated for characterizing the tissue in terms of some optical properties. A negative axicon structure chemically etched inside the fiber tip is employed as optical probe in the OCT. This probe generates a quality Bessel beam owning a large depth-of-field, ∼700 µm and small central spot size, ∼3 µm. The OCT system is probing the sample without using any microscopic lens. For experimental validation, the OCT imaging of chicken tissue has been obtained along with estimation of its refractive index and optical attenuation coefficient. Afterwards, the cancerous tissue is differentiated from the normal tissue based on the OCT imaging, refractive index, and optical attenuation coefficient. The respective tissue samples are collected from the human liver and pancreas. This probe could be a useful tool for endoscopic or minimal-invasive inspection of malignancy inside the tissue either at early-stage or during surgery.
This work demonstrates an interferometric technique to measure the refractive index (RI) of microliter volume of biosample solutions with the help of an optical fiber negative axicon and Bessel beam with the micrometer-size central spot. The RI measuring device consists of a broadband superluminescent diode (SLD) source along with an optical circulator and spectrometer. The axicon optical fiber probe packaged with a glass slide is connected to a broadband SLD source through an optical circulator, and a drop of microliter bioliquid sample is placed on the packaged probe’s head. The reflected light from the glass–liquid interface couples back to the axicon probe and interferes with the reference beam generated at the air–glass interface of the axicon. The interference spectrum is further analyzed by applying the fast Fourier transform to calculate power from the respective interface and solve the Fresnel equation for the RI measurement. The RI of small sample volume of glucose solutions and bovine serum albumin protein solutions are reported as an application of the proposed method. This sensing platform shows promising applications in biomedicine for monitoring small volume various biosample concentrations. We also demonstrate RI measurement of flowing liquid sample using the developed setup in case the design can be considered for microfluidic channel research.
In this paper, we present a new approach for the enhancement of a highly underexposed color image using a power-law transformation operator. A function called exposure [1] is used to measure the intensity exposition of the image. This function facilitates the estimation of highly underexposed region of the given image. The chromatic information of the color space is decoupled from the achromatic information using HSV (Hue, Saturation and Intensity) model. The hue component, in the model is preserved to keep the original color composition of the image intact. The other two components of the model are saturation and intensity. These two components play a significant role in enhancement of highly underexposed images by recovering the lost information in the image. New power-law transformation operators are defined for the two components, i.e. saturation and intensity, to improve the tone of the image. The values of these two components are varied to get the enhanced image.