This work demonstrates an interferometric technique to estimate the reflected powers from dielectric interfaces and the reflection coefficient using the Fresnel equation for measurement of the refractive index (RI) of liquid samples. It uses low-coherence common-path optical interferometry that is commonly used for optical imaging. A uniquely designed optical fiber tip generating a high-quality non-diffractive Bessel beam probes liquid samples in a glass container non-invasively. The light reflected from different interfaces of the container is recollected by the same optical fiber tip. The reflected beams interfere with the reference beam generated at the fiber tip itself. This interference spectrum is further processed using fast-Fourier transform to measure reflected powers from the respective interfaces. The acquired powers are used to solve the Fresnel equation to find RI of liquid samples. As a proof of concept, experiments have been performed on several liquid samples including turbid media such as blood. This non-invasive interferometric technique could also be an ideal example confirming the Fresnel equation for reflection of light. Unlike other optical fiber-based RI sensors, this technique does not require temperature compensation. The method can be employed for inspection of the production process in terms of RI in pharmaceutical and chemical process plants, etc.
11 June 2018 in IEEE Journal of Selected Topics in Quantum Electronics
In this work, a deep-seated negative axicon fiber tip (DSNA-FT) generating the Bessel–Gauss beam is proposed as an optical probe for a common-path optical coherence tomography (CPOCT) imaging. The axicon at the optical fiber tip is fabricated by etching the tip of a selective optical fiber in hydrofluoric acid under the influence of capillary action. The nondiffracting type quasi-Bessel beam from the DSNA-FT having a long depth of field, ∼0.7 mm, is used for the CPOCT imaging of different type of samples, i.e., sticky tape, fish scale, and rice grain. The CPOCT with unique and simple optical fiber probe has achieved lateral resolution at least ∼3.3 μm maintained up to 3 mm working distance in air. This optical fiber tip is an excellent candidate for an endoscopic probe design.
10 October 2019 in Journal of Lightwave Technology
Experimental realization of a fiber Bragg grating-based compact, high-sensitive, and fully packaged single-axis accelerometer has been demonstrated. To verify experimentally observed results, simulation has been carried out for the performance comparison of packaged single-axis accelerometer with the cantilever of various materials. The experimental demonstrations have been conducted at unknown seismic vibrations of random frequencies as well as the vibrations of known frequencies. The experimental results for the reported seismic events (i.e., footprint and hammering) demonstrate that the developed fully packaged accelerometer possesses good response to the signals with random vibrations. The developed accelerometer holds a high sensitivity up to 88 pm/g in the broad bandwidth. Such a compact fully packaged accelerometer with improved sensitivity can be deployed at any civil engineering structures, such as highways, bridges, dams, tunnels, pipelines, and aeronautical platforms for broadband dynamic monitoring of the random vibrations ranging from 5 to 100 Hz.
This work demonstrates an interferometric technique to measure the refractive index (RI) of microliter volume of biosample solutions with the help of an optical fiber negative axicon and Bessel beam with the micrometer-size central spot. The RI measuring device consists of a broadband superluminescent diode (SLD) source along with an optical circulator and spectrometer. The axicon optical fiber probe packaged with a glass slide is connected to a broadband SLD source through an optical circulator, and a drop of microliter bioliquid sample is placed on the packaged probe’s head. The reflected light from the glass–liquid interface couples back to the axicon probe and interferes with the reference beam generated at the air–glass interface of the axicon. The interference spectrum is further analyzed by applying the fast Fourier transform to calculate power from the respective interface and solve the Fresnel equation for the RI measurement. The RI of small sample volume of glucose solutions and bovine serum albumin protein solutions are reported as an application of the proposed method. This sensing platform shows promising applications in biomedicine for monitoring small volume various biosample concentrations. We also demonstrate RI measurement of flowing liquid sample using the developed setup in case the design can be considered for microfluidic channel research.