(200 w) Introduction. Remote monitoring (RM) of cardiac implantable electronic device (CIED) diagnostics helps to identify patients potentially at risk of worsening heart failure (HF). Additionally, knowledge of patient HF-related symptoms is crucial for decision making. Patient smartphone applications may represent an ideal option to remotely collect this information. Purpose. To assess real-world HF patient access, acceptance, and adherence to use of an HF-dedicated smartphone application (HF app). Methods. In this study, 10 Italian hospitals administered a survey on smartphone/app use to HF patients with CIED. The subgroup who accepted it downloaded the HF app. Mean 1-year adherence of the HF app use was evaluated. Results. A total of 495 patients (67 ± 13 years, 79% males, 26% NYHA III–IV) completed the survey, of which 84% had access to smartphones and 85% were willing to use the HF app. In total, 311/495 (63%) downloaded the HF app. Patients who downloaded the HF app were younger and had higher school qualification. Patients who were ≥60 years old had higher mean 1-year adherence (54.1%) than their younger counterparts (42.7%; p < 0.001). Hospitals with RM-dedicated staff had higher mean 1-year patient adherence (64.0% vs. 33.5%; p < 0.001). Adherence to HF app decreased from 63.3% (weeks_1–13) to 42.2% (weeks_40–52, p < 0.001). Conclusions. High access and acceptance of smartphones/apps by HF patients with CIED allow HF app use for RM of patient signs/symptoms. Younger patients with higher school qualifications are more likely to accept HF app; however, older patients have higher long-term adherence.
The cornerstone of ablative therapy for atrial fibrillation (AF) is pulmonary vein isolation (PVI). Whether PVI should be added with additional lesions in persistent atrial fibrillation (PerAF) or for any post-ablative recurrent AF is a matter of debate. Whatever the ablative strategy, it must determine the choice of energy source to achieve the most durable lesion sets with the least likelihood of complications. Radiofrequency (RF) is the most studied thermal ablation technique. It can be combined with high-density electroanatomic mapping and can be used for both pulmonary and extrapulmonary atrial ablation. Cryoenergy is at least as effective as radiofrequency for PVI; it is rapid, relatively safe, and has a steep learning curve. Therefore, it has been proposed as a first-line approach for PVI-only procedures. More recently, a non-thermal technique based on the application of pulsed direct current (Pulsed Field Ablation—PFA) has been introduced. PFA causes cell death by opening cell membrane pores (electroporation) without a significant increase in tissue temperature. It is fast and does not alter the extracellular matrix as thermal techniques do, although it ends up causing long-lasting, transmural lesions. Most importantly, it is relatively selective on cardiac myocytes and therefore potentially safer than thermal techniques. Some PFA systems can be combined with electroanatomic mapping systems. However, as of now, it appears that these ablation technologies should be considered complementary rather than alternative for a number of practical and theoretical reasons.
Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Patients with structural heart disease (SHD) are at an increased risk of developing this arrhythmia and are particularly susceptible to the deleterious hemodynamic effects it carries. In the last two decades, catheter ablation (CA) has emerged as a valuable strategy for rhythm control and is currently part of the standard care for symptomatic relief in patients with AF. Growing evidence suggests that CA of AF may have potential benefits that extend beyond symptoms. In this review, we summarize the current knowledge of this intervention on SHD patients.
Background: The COVID-19 pandemic forced several European governments to impose severe lockdown measures. The reduction of physical activity during the lockdown could have been deleterious. Objective: The aim of this observational, retrospective study was to investigate the effect of the lockdown strategy on the physical activity burden and subsequent reassessment in a group of patients with heart failure who were followed by means of remote monitoring. Methods: We analyzed remote monitoring transmissions during the 3-month period immediately preceding the lockdown, 69 days of lockdown, and 3-month period after the first lockdown in a cohort of patients with heart failure from a general hospital in Lombardy, Italy. We compared variation of daily physical activity measured by cardiac implantable electrical devices with clinical variables collected in a hospital database. Results: We enrolled 41 patients with heart failure that sent 176 transmissions. Physical activity decreased during the lockdown period (mean 3.4, SD 1.9 vs mean 2.9, SD 1.8 hours/day; P<.001) but no significant difference was found when comparing the period preceding and following the lockdown (–0.0007 hours/day; P=.99). We found a significant correlation between physical activity reduction during and after the lockdown (R2=0.45, P<.001). The only significant predictor of exercise variation in the postlockdown period was the lockdown to prelockdown physical activity ratio. Conclusions: An excessive reduction of exercise in patients with heart failure decreased the tolerance to exercise, especially in patients with more comorbidities. Remote monitoring demonstrated exercise reduction, suggesting its potential utility to encourage patients to maintain their usual physical activity levels.
BACKGROUND The COVID-19 pandemic forced several European governments to impose severe lockdown measures. The reduction of physical activity during the lockdown could have been deleterious. OBJECTIVE The aim of this observational, retrospective study was to investigate the effect of the lockdown strategy on the physical activity burden and subsequent reassessment in a group of patients with heart failure who were followed by means of remote monitoring. METHODS We analyzed remote monitoring transmissions during the 3-month period immediately preceding the lockdown, 69 days of lockdown, and 3-month period after the first lockdown in a cohort of patients with heart failure from a general hospital in Lombardy, Italy. We compared variation of daily physical activity measured by cardiac implantable electrical devices with clinical variables collected in a hospital database. RESULTS We enrolled 41 patients with heart failure that sent 176 transmissions. Physical activity decreased during the lockdown period (mean 3.4, SD 1.9 vs mean 2.9, SD 1.8 hours/day; P<.001) but no significant difference was found when comparing the period preceding and following the lockdown (–0.0007 hours/day; P=.99). We found a significant correlation between physical activity reduction during and after the lockdown (R2=0.45, P<.001). The only significant predictor of exercise variation in the postlockdown period was the lockdown to prelockdown physical activity ratio. CONCLUSIONS An excessive reduction of exercise in patients with heart failure decreased the tolerance to exercise, especially in patients with more comorbidities. Remote monitoring demonstrated exercise reduction, suggesting its potential utility to encourage patients to maintain their usual physical activity levels.