Zeeshan Anjum Memon

Mr. Zeeshan Anjum Memon


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2022 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ZMZeeshan Anjum Memon
Zeeshan Anjum Memon
DSDalila Mat Said
Dalila Mat Said
MHMohammad Yusri Hassan
Mohammad Yusri Hassan
ZLZohaib Hussain Leghari
Zohaib Hussain Leghari
GSGul Sahar
Gul Sahar
The installation of Distributed Generation (DG) units in the Radial Distribution Networks (RDNs) has significant potential to minimize active power losses in distribution networks. However, inaccurate size(s) and location(s) of DG units increase power losses and associated Annual Financial Losses (AFL). A comprehensive review of the literature reveals that existing analytical, metaheuristic and hybrid algorithms employed on DG allocation problems trap in local or global optima resulting in higher power losses. To address these limitations, this article develops a parallel hybrid Arithmetic Optimization Algorithm and Salp Swarm Algorithm (AOASSA) for the optimal sizing and placement of DGs in the RDNs. The proposed parallel hybrid AOASSA enables the mutual benefit of both algorithms, i.e., the exploration capability of the SSA and the exploitation capability of the AOA. The performance of the proposed algorithm has been analyzed against the hybrid Arithmetic Optimization Algorithm Particle Swarm Optimization (AOAPSO), Salp Swarm Algorithm Particle Swarm Optimization (SSAPSO), standard AOA, SSA, and Particle Swarm Optimization (PSO) algorithms. The results obtained reveals that the proposed algorithm produces quality solutions and minimum power losses in RDNs. The Power Loss Reduction (PLR) obtained with the proposed algorithm has also been validated against recent analytical, metaheuristic and hybrid optimization algorithms with the help of three cases based on the number of DG units allocated. Using the proposed algorithm, the PLR and associated AFL reduction of the 33-bus and 69-bus RDNs improved to 65.51% and 69.14%, respectively. This study will help the local distribution companies to minimize power losses and associated AFL in the long-term planning paradigm.

23 April 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
ZMZeeshan Anjum Memon
Zeeshan Anjum Memon
DSDalila Mat Said
Dalila Mat Said
MHMohammad Yusri Hassan
Mohammad Yusri Hassan
Hafiz Mudassir MunirHafiz Mudassir Munir
Hafiz Mudassir Munir
FAFaisal Alsaif
Faisal Alsaif
SASager Alsulamy
Sager Alsulamy
The rapid depletion of fossil fuel motivates researchers and policymakers to switch from the internal combustion engine (ICE) to plug-in electric vehicles (PEVs). However, the electric power distribution networks are congested, which lowers the accommodation of PEVs and produces higher power losses. Therefore, the study proposes an effective deterministic methodology to maximize the accommodation of PEVs and percentage power loss reduction (%PLR) in radial distribution networks (RDNs). In the first stage, the PEVs are allocated to the best bus, which is chosen based on the loading capacity to power loss index (LCPLI), and the accommodation profile of PEVs is developed based on varying states of charge (SoC) and battery capacities (BCs). In the second stage, the power losses are minimized in PEV integrated networks with the allocation of DG units using a recently developed parallel-operated arithmetic optimization algorithm salp swarm algorithm (AOASSA). In the third stage, the charging and discharging ratios of PEVs are optimized analytically to minimize power losses after planning PEVs and DGs. The outcomes reveal that bus-2 is the most optimal bus for accommodation of PEVs, as it has the highest level of LCPLI, which is 9.81 in the 33-bus system and 28.24 in the 69-bus system. The optimal bus can safely accommodate the largest number of electric vehicles, with a capacity of 31,988 units in the 33-bus system and 92,519 units in the 69-bus system. Additionally, the parallel-operated AOASSA mechanism leads to a reduction in power losses of at least 0.09% and 0.25% compared with other algorithms that have been previously applied to the 33-bus and 69-bus systems, respectively. Moreover, with an optimal charging and discharging ratio of PEVs in the IEEE-33-bus radial distribution network (RDN), the %PLR further improved by 3.08%, 4.19%, and 2.29% in the presence of the optimal allocation of one, two and three DG units, respectively. In the IEEE-69-bus RDN, the %PLR further improved by 0.09%, 0.09%, and 0.08% with optimal charge and discharge ratios in the presence of one, two, and three DG units, respectively. The proposed study intends to help the local power distribution companies to maximize accommodation of PEV units and minimize power losses in RDNs.

9 March 2022
Verified
Book Chapter
Closed access
PDF file
ZMZeeshan Anjum Memon
Zeeshan Anjum Memon
MHMohammad Yusri Hassan
Mohammad Yusri Hassan
DSDalila Mat Said
Dalila Mat Said
ZLZohaib Hussain Leghari
Zohaib Hussain Leghari
PSPervez Hameed Shaikh
Pervez Hameed Shaikh