A lead bismuth eutectic (LBE) spallation target will be installed in the Target Test Facility (TEF-T) in the Japan Proton Accelerator Research Complex (J-PARC). The spallation target vessel filled with LBE is made of type 316L stainless steel. However, various damages, such as erosion/corrosion damage and liquid metal embrittlement caused by contact with flowing LBE at high temperature, and irradiation hardening caused by protons and neutrons, may be inflicted on the target vessel, which will deteriorate the steel and might break the vessel. To monitor the target vessel for prevention of an accident, an ultrasonic technique has been proposed to establish off-line evaluation for estimating vessel material status during the target maintenance period. Basic R&D must be carried out to clarify the dependency of ultrasonic wave propagation behavior on material microstructures and obtain fundamental knowledge. As a first step, ultrasonic waves scattered by the grains of type 316L stainless steel are investigated using new experimental and numerical approaches in the present study. The results show that the grain size can be evaluated exactly and quantitatively by calculating the attenuation coefficient of the ultrasonic waves scattered by the grains. The results also show that the scattering regimes of ultrasonic waves depend heavily on the ratio of wavelength to average grain size, and are dominated by grains of extraordinarily large size along the wave propagation path.
1 March 2000 in Journal of Nuclear Science and Technology
Electromagnetic induction is an effective technique for local velocity measurements in heavy liquid metals, such as mercury and lead/lead–bismuth eutectic. In this regard, Ricou and Vives’ probe and von Weissenfluh’s probe are well-known instruments that use permanent magnets. However, the sensitivity and measurement volume of the probes unexpectedly vary because the permanent magnet is demagnetized as the temperature increases up to the Curie temperature. Furthermore, such probes do not work for local velocity measurements over the Curie temperature. In this study, a new electromagnetic probe using a miniature electromagnet was developed as a prototype sensor to overcome such disadvantages of the permanent magnet. The diameter and the length of the sensor were 6 and 155 mm, respectively. The electromagnet incorporated in the sensor was excited by a direct current of 50 mA. The fundamental performance of the sensor was confirmed in a room-temperature experiment by measuring the local velocity of flowing mercury in a square channel. Numerical velocity profiles were calculated and compared with those of the experiment to clarify the validity of the measured velocity profiles. In this paper, the sensitivity and the measurement volume of the probe were assessed. The validity of the measured velocity profiles was confirmed by the calculated results.
After the Fukushima accident caused by the Great East Japan Earthquake, nuclear transmutation acquired much interest as an effective option of nuclear waste management. The Japan Atomic Energy Agency (JAEA) proposes the transmutation of minor actinides by an accelerator-driven system (ADS) using lead–bismuth eutectic alloy (Pb-Bi) as a spallation target and a coolant of the subcritical core. The current ADS design has 800 MWth of rated power, which is driven by a 20 MW proton LINAC, to transmute minor actinides generated from 10 units of standard light water reactors. To obtain the data required for ADS design, including the European MYRRHA project, JAEA plans to build a Transmutation Experimental Facility (TEF) within the framework of the J-PARC project. TEF consists of two buildings: one is an ADS target test facility (TEF-T), in which will be installed a high-power Pb-Bi spallation target, and the other is the Transmutation Physics Experimental Facility (TEF-P), which will set up a fast critical/subcritical assembly driven by a low-power proton beam. TEF will be located at the end of the 400 MeV LINAC of J-PARC and accept a 250-kW proton beam with repetition rate of 25 Hz. As major research and development items of TEF-T, irradiation tests for structural materials and engineering tests for Pb-Bi applications to determine the effective lifetime of the proton beam window will be performed. The reference design parameter, that considers operating conditions of the ADS transmutor, was determined by thermal-hydraulic analyses and structural analyses. When the target operates with full-power beam, a fast neutron spectrum field is formed around the target, and it is possible to apply multipurpose usage. Various research plans have been proposed, and layout of the experimental hall surrounding the target is under way. Basic physics application such as measurements of nuclear reaction data is considered as one of the major purposes.
To perform basic Research and Development for future Accelerator-driven Systems (ADSs), Japan Proton Accelerator Research Complex (J-PARC) will construct an ADS target test facility. A Lead–Bismuth Eutectic (LBE) spallation target will be installed in the target test facility and bombarded by pulsed proton beams (250 kW, 400 MeV, 25 Hz, and 0.5 ms pulse duration). To realize the LBE spallation target, cavitation damage due to pressure changes in the liquid metal should be determined, preliminarily, because such damage is considered to be very critical, from the viewpoint of target safety and lifetime. In this study, cavitation damage due to pressure waves caused by pulsed proton beam injection and turbulent liquid metal flow, were studied, numerically, from the viewpoint of single cavitation bubble dynamics. Specifically, the threshold of cavitation and effects of flow speed fluctuation on cavitation bubble dynamics, in an orifice structure, were investigated in the present work. The results showed that the LBE spallation target did not undergo cavitation damage, under normal nominal operation conditions, mainly because of the long pulse duration of the pulsed proton beam and the low liquid metal flow velocity. Nevertheless, the possibility of cavitation damage in the orifice structure, under certain extreme transient LBE flow conditions, cannot be neglected.