Three-dimensional printing, especially fused filament fabrication (FFF), offers great possibilities in (bio-)medical applications, but a major downside is the difficulty in sterilizing the produced parts. This study evaluates the questions of whether autoclaving is a possible solution for FFF-printed parts and if the printer itself could be seen as an inherent sterilization method. In a first step, an investigation was performed on the deformation of cylindrically shaped test parts after running them through the autoclaving process. Furthermore, the inherent sterility possibilities of the printing process itself were evaluated using culture medium sterility tests. It could be shown that, depending on the needed accuracy, parts down to a diameter of 5–10 mm can still be sterilized using autoclaving, while finer parts suffer from major deformations. For these, inherent sterilization of the printer itself is an option. During the printing process, over a certain contact time, heat at a higher level than that used in autoclaving is applied to the printed parts. The contact time, depending on the printing parameters, is calculated using the established formula. The results show that for stronger parts, autoclaving offers a cheap and good option for sterilization after FFF-printing. However, the inherent sterility possibilities of the printer itself can be considered, especially when printing with small layer heights for finer parts.
Although anterior cruciate ligament (ACL) tear-prevention programs may be effective in the (secondary) prevention of a subsequent ACL injury, little is known, yet, on their effectiveness and feasibility. This study assesses the effects and implementation capacity of a secondary preventive motor-control training (the Stop-X program) after ACL reconstruction. A multicenter, single-blind, randomized controlled, prospective, superiority, two-arm design is adopted. Subsequent patients (18–35 years) with primary arthroscopic unilateral ACL reconstruction with autologous hamstring graft are enrolled. Postoperative guideline rehabilitation plus Classic follow-up treatment and guideline rehabilitation plus the Stop-X intervention will be compared. The onset of the Stop-X program as part of the postoperative follow-up treatment is individualized and function based. The participants must be released for the training components. The endpoint is the unrestricted return to sport (RTS) decision. Before (where applicable) reconstruction and after the clearance for the intervention (aimed at 4–8 months post surgery) until the unrestricted RTS decision (but at least until 12 months post surgery), all outcomes will be assessed once a month. Each participant is consequently measured at least five times to a maximum of 12 times. Twelve, 18 and 24 months after the surgery, follow-up-measurements and recurrence monitoring will follow. The primary outcome assessement (normalized knee-separation distance at the Drop Jump Screening Test (DJST)) is followed by the functional secondary outcomes assessements. The latter consist of quality assessments during simple (combined) balance side, balance front and single-leg hops for distance. All hop/jump tests are self-administered and filmed from the frontal view (3-m distance). All videos are transferred using safe big content transfer and subsequently (and blinded) expertly video-rated. Secondary outcomes are questionnaires on patient-reported knee function, kinesiophobia, RTS after ACL injury and training/therapy volume (frequency – intensity – type and time). All questionnaires are completed online using the participants’ pseudonym only. Group allocation is executed randomly. The training intervention (Stop-X arm) consists of self-administered home-based exercises. The exercises are step-wise graduated and follow wound healing and functional restoration criteria. The training frequency for both arms is scheduled to be three times per week, each time for a 30 min duration. The program follows current (secondary) prevention guidelines. Repeated measurements gain-score analyses using analyses of (co-)variance are performed for all outcomes. German Clinical Trials Register, identification number DRKS00015313 . Registered on 1 October 2018.
The Masquelet technique for the treatment of large bone defects is a two-stage procedure based on an induced membrane. We eliminate the first surgical step by using a decellularized dermal skin graft (Epiflex®) populated with bone marrow mononuclear cells (BMC), as a replacement for the induced membrane. The aim of this study was to demonstrate the feasibility of this technology and provide evidence of equivalent bone healing in comparison to the induced membrane-technique. Therefore, 112 male Sprague–Dawley rats were allocated in six groups and received a 10 mm femoral defect. Defects were treated with either the induced membrane or decellularized dermis, with or without the addition of BMC. Defects were then filled with a scaffold (β-TCP), with or without BMC. After a healing time of eight weeks, femurs were taken for histological, radiological and biomechanical analysis. Defects treated with Epiflex® showed increased mineralization and bone formation predominantly in the transplanted dermis surrounding the defect. No significant decrease of biomechanical properties was found. Vascularization of the defect could be enhanced by addition of BMC. Considering the dramatic reduction of a patient’s burden by the reduced surgical stress and shortened time of treatment, this technique could have a great impact on clinical practice.
Lectures remain an important teaching method to present and structure knowledge to many students concurrently. Adequate measures are necessary to maintain the quality of the lectures. The aim of this study was to determine the impact on the lecture quality using written structured feedback and to compare the ratings of surgical lectures between students and surgical peers. Prospective analysis of two consecutive surgical lecture series for undergraduate students at Goethe-University Medical School was performed before and after evaluation of the lecturers via independent written feedback from trained undergraduate students and surgeons. The 22-item feedback instrument covered three areas of performance: content, visualization, and delivery. Additional suggestions for improvement were provided from both students and surgical peers who anonymously attended the lectures. The lecturers, experienced surgeons, as well as the student and peer raters were blinded in terms of the aim and content of the study. Their response to the feedback was collected using a web-based 13-item questionnaire. The Kendall’s-W coefficient was computed to calculate inter-rater reliability (IRR). Differences between ratings before and after feedback were analyzed using Student’s t-test for dependent samples. The Kolmogorov-Smirnov-test was used for independent samples. A total of 22 lectures from a possible 32 given by 13 lecturers were included and analyzed by at least three surgeons and two students. There were significant improvements in overall score as well as in the details of 9 of the 13 items were found. The average inter-rater reliability was 0.71. There were no differences in the ratings as a function of the rater’s level of expertise (peers vs. students). We found that 13/23 lecturers (56.5%) answered the questionnaire, and 92% strongly agreed that the written feedback was useful. 76.9% of the lecturers revised their lecture based on the written feedback requiring on average 112.5 min (range from 20 to 300 min). Overall, this study indicates that structured written feedback provided by trained peers and students that is subsequently discussed by the lecturers concerned is a highly effective and efficient method to improve aspects of lecturing. We anticipate that structured written feedback by trained students that is discussed by the lecturers concerned will improve lecturing.
31 March 2022 in European Journal of Trauma and Emergency Surgery
Introduction: The aim of this article is to show a new concept of indication and application of the MUTARS® RS Cup System in primary and revision hip arthroplasty. This integrated system is applicable for different acetabular cup replacements in patients with acetabular fractures or instable defects, as well as periprosthetic acetabular fractures. The MUTARS® RS Cup System is a cementless revision cup for insertion into the acetabulum with an integrated polyethylene cup, which fits to a regular or bipolar head. This system replaces the conventional approach for acetabular revision with a Burch-Schneider ring, in which a normal polyethylene cup is cemented. This interface with its complications is avoided with this system of a titanium revision cup with integrated polyethylene cup. Steps of preoperative planning and the intraoperative implementation will be highlighted in this article. Material and methods: This system was applied in 49 patients with 52 MUTARS® RS Cup Implantations in 30 males, 22 females, with an average age of 76,1 years (36,9–94,4 years). Results and discussion: The system shows a good operative feasibility, as well as a reliable handling and safe method for stable treatment of non-reconstructable acetabular fractures or acetabular incongruencies and instabilities.