Yiyu Hong

Mr. Yiyu Hong

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2022 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Eduardo Conde-SousaEduardo Conde-Sousa
Eduardo Conde-Sousa
JVJoão Vale
João Vale
MFMing Feng
Ming Feng
KXKele Xu
Kele Xu
YWYin Wang
Yin Wang
APAntónio Polónia
António Polónia
Breast cancer is the most common malignancy in women worldwide, and is responsible for more than half a million deaths each year. The appropriate therapy depends on the evaluation of the expression of various biomarkers, such as the human epidermal growth factor receptor 2 (HER2) transmembrane protein, through specialized techniques, such as immunohistochemistry or in situ hybridization. In this work, we present the HER2 on hematoxylin and eosin (HEROHE) challenge, a parallel event of the 16th European Congress on Digital Pathology, which aimed to predict the HER2 status in breast cancer based only on hematoxylin–eosin-stained tissue samples, thus avoiding specialized techniques. The challenge consisted of a large, annotated, whole-slide images dataset (509), specifically collected for the challenge. Models for predicting HER2 status were presented by 21 teams worldwide. The best-performing models are presented by detailing the network architectures and key parameters. Methods are compared and approaches, core methodologies, and software choices contrasted. Different evaluation metrics are discussed, as well as the performance of the presented models for each of these metrics. Potential differences in ranking that would result from different choices of evaluation metrics highlight the need for careful consideration at the time of their selection, as the results show that some metrics may misrepresent the true potential of a model to solve the problem for which it was developed. The HEROHE dataset remains publicly available to promote advances in the field of computational pathology.

23 July 2018 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
YHYiyu Hong
Yiyu Hong
JKJongweon Kim
Jongweon Kim

16 May 2024 in Cancers
Verified
Journal Article
Open access
PDF file
JSJoo Hye Song
Joo Hye Song
EKEun Ran Kim
Eun Ran Kim
YHYiyu Hong
Yiyu Hong
ISInsuk Sohn
Insuk Sohn
SASoomin Ahn
Soomin Ahn
KJKee-Taek Jang
Kee-Taek Jang
According to the current guidelines, additional surgery is performed for endoscopically resected specimens of early colorectal cancer (CRC) with a high risk of lymph node metastasis (LNM). However, the rate of LNM is 2.1–25.0% in cases treated endoscopically followed by surgery, indicating a high rate of unnecessary surgeries. Therefore, this study aimed to develop an artificial intelligence (AI) model using H&E-stained whole slide images (WSIs) without handcrafted features employing surgically and endoscopically resected specimens to predict LNM in T1 CRC. To validate with an independent cohort, we developed a model with four versions comprising various combinations of training and test sets using H&E-stained WSIs from endoscopically (400 patients) and surgically resected specimens (881 patients): Version 1, Train and Test: surgical specimens; Version 2, Train and Test: endoscopic and surgically resected specimens; Version 3, Train: endoscopic and surgical specimens and Test: surgical specimens; Version 4, Train: endoscopic and surgical specimens and Test: endoscopic specimens. The area under the curve (AUC) of the receiver operating characteristic curve was used to determine the accuracy of the AI model for predicting LNM with a 5-fold cross-validation in the training set. Our AI model with H&E-stained WSIs and without annotations showed good performance power with the validation of an independent cohort in a single center. The AUC of our model was 0.758–0.830 in the training set and 0.781–0.824 in the test set, higher than that of previous AI studies with only WSI. Moreover, the AI model with Version 4, which showed the highest sensitivity (92.9%), reduced unnecessary additional surgery by 14.2% more than using the current guidelines (68.3% vs. 82.5%). This revealed the feasibility of using an AI model with only H&E-stained WSIs to predict LNM in T1 CRC.

10 July 2019 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YHYiyu Hong
Yiyu Hong
JKJongweon Kim
Jongweon Kim
High Efficiency Advanced Audio Coding (HE-AAC) is a lossy compression method for digital audio data which supplies high-quality audio at a very low bit rate. In this paper, the audio blind watermarking algorithm, on the basis of autocorrelation modulation, is introduced to maximize the robustness against low-bit rate HE-AAC. The watermark is embedded by modulating the normalized correlation of the original signal as well as its delayed version. The signal-to-noise ratio of before and after HE-AAC compression decides the strength of the embedding watermark. The watermarking embedding strength is guaranteed by the feedback process. The effectiveness of the proposed method is proven using the Perceptual Evaluation of Audio Quality algorithm and bit error rate of recovered watermarks under HE-AAC compression on mono, stereo and 5.1 channel audio. Experimental results show that the proposed method provides good performance in terms of imperceptibility, robustness and data payload compared with some recent state-of-the-art watermarking methods under an MPEG-2 Audio Layer III (MP3) compression attack.

1 January 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
Eduardo Conde-SousaEduardo Conde-Sousa
Eduardo Conde-Sousa
JVJoão Vale
João Vale
MFMing Feng
Ming Feng
KXKele Xu
Kele Xu
YWYin Wang
Yin Wang
APAntónio Polónia
António Polónia
Background and Objectives: Breast cancer is the most common malignancy in women and is responsible for more than half a million deaths each year. Early and accurate diagnosis is therefore of utmost importance. Human expertise is required to diagnose and correctly classify breast cancer and determine appropriate therapy, which depends on evaluating the expression of various biomarkers such as the transmembrane protein receptor HER2. This evaluation requires several steps, including specialized techniques such as immunohistochemistry or in situ hybridization to assess HER2 status. In this work, we present the HEROHE challenge, a parallel event of the 16th European Congress on Digital Pathology, which aims to automate the assessment of HER2 status based only on hematoxylin and eosin stained tissue samples from invasive breast cancer. Methods: The organizational protocol is presented, from sample preparation to timeline and evaluation metric. The best-performing models are presented by detailing the network architectures and key parameters. Results: Models for assessing HER2 status were presented by 21 teams worldwide. Their results in the main dataset and in the subset of cases classified as equivocal by the immunohistochemistry test were evaluated. Methods were compared and approaches, core methodologies, and software choices were contrasted. Conclusions: Promising results were obtained, especially for the subset of equivocal cases. The performance of each model was evaluated according to multiple evaluation metrics highlighting that the chosen metric may be misleading and, in some extreme scenarios, may distort the perception of the adequacy of the model to solve the problem.

25 September 2017 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YHYiyu Hong
Yiyu Hong
JKJongweon Kim
Jongweon Kim
With the rapid development of three-dimensional (3D) technology and an increase in the number of available models, issues with copyright protection of 3D models are inevitable. In this paper, we propose a 2D-view depth image- and convolutional neural network (CNN)-based 3D model identification method. To identify a 3D model, we first need an adequate number of the modified versions that could be made by copyright infringers. Then, they can be represented by a number of 2D-view depth images that are captured from evenly distributed vertices on a regular convex polyhedron. Finally, a CNN is trained by these depth images to acquire the capability of identifying the 3D model. The experiment carried out with the dataset of Shape Retrieval Contest 2015 (SHREC’15): Non-Rigid 3D Shape Retrieval shows the practicability of our method, which yields 93.5% accuracy. The effectiveness of the proposed method is demonstrated via evaluation in the latest standard benchmark SHREC’17 Deformable Shape Retrieval with Missing Parts. It clearly shows superior or comparable performance to state-of-the-art methods, shown by the fact that it is in the top three of the 11 participating methods (without counting different runs).