Thomas Helbig

Mr. Thomas Helbig

Mechanical Engineering, Technische Universität Ilmenau, Ilmenau, Thuringia, Germany
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
JDJonas Paul David
Jonas Paul David
THThomas Helbig
Thomas Helbig
Hartmut F. WitteHartmut F. Witte
Hartmut F. Witte
For technical or medical applications, the knowledge of the exact kinematics of the human hand is key to utilizing its capability of handling and manipulating objects and communicating with other humans or machines. The optimal relationship between the number of measurement parameters, measurement accuracy, as well as complexity, usability and cost of the measuring systems is hard to find. Biomechanic assumptions, the concepts of a biomechatronic system and the mechatronic design process, as well as commercially available components, are used to develop a sensorized glove. The proposed wearable introduced in this paper can measure 14 of 15 angular values of a simplified hand model. Additionally, five contact pressure values at the fingertips and inertial data of the whole hand with six degrees of freedom are gathered. Due to the modular design and a hand size examination based on anthropometric parameters, the concept of the wearable is applicable to a large variety of hand sizes and adaptable to different use cases. Validations show a combined root-mean-square error of 0.99° to 2.38° for the measurement of all joint angles on one finger, surpassing the human perception threshold and the current state-of-the-art in science and technology for comparable systems.

25 January 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
SKStefan Kreipe
Stefan Kreipe
THThomas Helbig
Thomas Helbig
Hartmut F. WitteHartmut F. Witte
Hartmut F. Witte
NSNikolaus-Peter Schumann
Nikolaus-Peter Schumann
CAChristoph Anders
Christoph Anders
The design of human-machine interfaces of occupational exoskeletons is essential for their successful application, but at the same time demanding. In terms of information gain, biosensoric methods such as surface electromyography (sEMG) can help to achieve intuitive control of the device, for example by reduction of the inherent time latencies of a conventional, non-biosensoric, control scheme. To assess the reliability of sEMG onset detection under close to real-life circumstances, shoulder sEMG of 55 healthy test subjects was recorded during seated free arm lifting movements based on assembly tasks. Known algorithms for sEMG onset detection are reviewed and evaluated regarding application demands. A constant false alarm rate (CFAR) double-threshold detection algorithm was implemented and tested with different features. Feature selection was done by evaluation of signal-to-noise-ratio (SNR), onset sensitivity and precision, as well as timing error and deviation. Results of visual signal inspection by sEMG experts and kinematic signals were used as references. Overall, a CFAR algorithm with Teager-Kaiser-Energy-Operator (TKEO) as feature showed the best results with feature SNR = 14.48 dB, 91% sensitivity, 93% precision. In average, sEMG analysis hinted towards impending movements 215 ms before measurable kinematic changes.

27 February 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
JDJonas Paul David
Jonas Paul David
THThomas Helbig
Thomas Helbig
Hartmut F. WitteHartmut F. Witte
Hartmut F. Witte
For technical or medical applications, the knowledge of the exact kinematics of the human hand is key to utilizing its capability to handle and manipulate objects and to communicate with other humans or machines. The optimal relationship between the number of measurement parameters, measurement accuracy as well as complexity, usability and cost of the measuring systems is hard to find. Biomechanic assumptions, the concepts of a biomechatronic system and the mechatronic design process as well as commercially available components are used to develop a sensorized glove. The proposed wearable can measure 14 of 15 angular values of a simplified hand model introduced in this paper. Additionally, five contact pressure values at the fingertips and inertial data of the whole hand with a degree of freedom of six are gathered. Due to the modular design and a hand size examination based on anthropometric parameters, the concept of the wearable is applicable for a large variety of hand sizes and adaptable to different use cases. Validations show a combined root-mean-square error of 0.99° to 2.38° for the measurement of all joint angles at one finger, surpassing the human perception threshold and the current state of the art in science and technology for comparable systems.

10 May 2023 in Actuators
Verified
Journal Article
Open access
PDF file
MJMax Jäger
Max Jäger
THThomas Helbig
Thomas Helbig
MGMoritz Goos
Moritz Goos
SKSebastian Köhring
Sebastian Köhring
Hartmut F. WitteHartmut F. Witte
Hartmut F. Witte
The parallel connection of technical and biological systems with a comparable mechanical behavior offers the possibility of reducing the interaction forces between those systems. Especially in the context of human–robot interaction (e.g., exoskeletons), it can improve user safety and acceptance at the same time. With this aim, we used antagonistic actuators with nonlinear compliance for a modular upper-extremity exoskeleton following biological paragons, mirroring the “blueprint” of its human user. In a test-bed setup, we compared antagonistic compliant actuation with antagonistic stiff, unilateral stiff and unilateral compliant actuation in the artificial “elbow joint” of the exoskeleton test bed. We show that this type of actuation allows the variation of the joint stiffness during motion, independent of the position. With the approach we propose, compliance leads to reduced force peaks and angular jerk, without sacrifices in terms of time constants and overshoot of amplitudes. We conclude that the presented actuation principle has considerable benefits in comparison to other types of exoskeleton actuation, even when using only commercially available and 3D printed components. Based on our work, further investigations into the control of compliant antagonistically actuated exoskeletons become realizable.

1 January 2000
Verified
Book Chapter
Closed access
PDF file
RLRainer Lindenau
Rainer Lindenau
THThomas Helbig
Thomas Helbig