Max Jäger

Mr. Max Jäger

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2023 in Actuators
Verified
Journal Article
Open access
PDF file
MJMax Jäger
Max Jäger
THThomas Helbig
Thomas Helbig
MGMoritz Goos
Moritz Goos
SKSebastian Köhring
Sebastian Köhring
Hartmut F. WitteHartmut F. Witte
Hartmut F. Witte
The parallel connection of technical and biological systems with a comparable mechanical behavior offers the possibility of reducing the interaction forces between those systems. Especially in the context of human–robot interaction (e.g., exoskeletons), it can improve user safety and acceptance at the same time. With this aim, we used antagonistic actuators with nonlinear compliance for a modular upper-extremity exoskeleton following biological paragons, mirroring the “blueprint” of its human user. In a test-bed setup, we compared antagonistic compliant actuation with antagonistic stiff, unilateral stiff and unilateral compliant actuation in the artificial “elbow joint” of the exoskeleton test bed. We show that this type of actuation allows the variation of the joint stiffness during motion, independent of the position. With the approach we propose, compliance leads to reduced force peaks and angular jerk, without sacrifices in terms of time constants and overshoot of amplitudes. We conclude that the presented actuation principle has considerable benefits in comparison to other types of exoskeleton actuation, even when using only commercially available and 3D printed components. Based on our work, further investigations into the control of compliant antagonistically actuated exoskeletons become realizable.

1 January 2014
Verified
Conference Paper
Closed access
MJMax Jäger
Max Jäger
MKM. Kohlmann
M. Kohlmann
VSV. Staudt
V. Staudt
ASA. Steimel
A. Steimel
MGM. Gorski
M. Gorski
High-voltage DC (HVDC) transmission lines offer highly efficient transport of electric energy. If applied to comparatively weak grids, self-commutated converters are the proper choice, because they allow stabilizing the grid in case of faults by injecting reactive power. However, proper control methods have to be applied - normal operation and the reaction to various fault conditions need careful analysis. For this purpose a scaled-down test bench for an HVDC system has been realised. Four modular multilevel-converters (MMCs) operate together, defining a multiterminal DC grid. The test bench provides a realistic environment to verify multiterminal operation and fault mitigation. For this purpose, a lot of signals have to be measured and transferred to the control. The control in turn has to provide many switching signals for the IGBT used. This paper presents layout and structure of the entire control and a modular control system that has been configured for the tasks of this HVDC-system test bench and includes first measurement results of controlled operation of the test bench.

3 November 2025 in BMC Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MJMax Jäger
Max Jäger
KUKatja Uhrhan
Katja Uhrhan
CMChristine Mucha
Christine Mucha
MAMaría Alejandra Guzmán Alfaro
María Alejandra Guzmán Alfaro
HWHartmut Witte
Hartmut Witte
The mechanical properties of tumor tissue differ from those of healthy tissue. Therefore, surgeons palpate accessible surgical sites to determine tumor boundaries prior to resection. However, palpation is not possible during minimally invasive surgery, so instrumented palpation is required instead. This study investigates the suitability of an engineering method that combines mechanical object scanning and indentation to determine Young’s modulus of soft, tissue-like materials. To establish a defined reference, we tested our concept on silicone phantoms containing stiff tumor-like inclusions. We used a sensor consisting of a load cell connected to a rigid probe with a spherical indenter tip. Young’s modulus was calculated by measured force, indentation depth, and indenter geometry. These results were compared with those of a palpation experiment on the same specimens, conducted with surgeons. Validation results reflect the accuracy of the method. Error in estimation of Young’s modulus is: soft material 6.7%, stiff material 44.9%. Repeatability is high, with a standard deviation < 7%. By scanning a phantom and creating a stiffness image, we were able to identify the location and shape of the inclusion more clearly than experienced surgeons could using manual palpation. Looking ahead, the prospect of miniaturizing the presented technique for localizing tumor boundaries during surgery seems promising.