Huiyi Yan

Ms. Huiyi Yan


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2017 in Molecules
Verified
Journal Article
Open access
PDF file
HYHuiyi Yan
Huiyi Yan
HYHongye Yang
Hongye Yang
KLKang Li
Kang Li
JYJian Yu
Jian Yu
CHCui Huang
Cui Huang
One of the primary causes for the failure of glass ionomer cement (GIC) is secondary caries. To enhance the anti-microbial performance of GIC without affecting its mechanical properties, chlorhexidine (CHX) was encapsulated in expanded-pore mesoporous silica nanoparticles (pMSN) to synthesize CHX@pMSN. CHX@pMSN was added at three mass fractions (1%, 5%, and 10% (w/w)) to GIC powder as the experimental groups. Pure GIC was set as the control group. The mechanical and anti-biofilm properties of GIC from each group were tested. The results demonstrated that CHX was successfully encapsulated on/into pMSN, and the encapsulating efficiency of CHX was 44.62% in CHX@pMSN. The anti-biofilm ability was significantly enhanced in all experimental groups (p < 0.001) compared with that in the control group. CHX was continuously released, and anti-biofilm ability was maintained up to 30 days. In addition, the mechanical properties (compressive strength, surface hardness, elastic modulus, water sorption, and solubility) of 1% (w/w) group were maintained compared with those in the control group (p > 0.05). In conclusion, adding 1% (w/w) CHX@pMSN to GIC led to conspicuous anti-biofilm ability and had no adverse effect on the mechanical properties of this restorative material. This study proposes a new strategy for preventing secondary caries by using CHX@pMSN-modified GIC.

20 June 2026 in BMC Oral Health
Verified
Journal Article
Open access
XBXueying Bai
Xueying Bai
YXYufei Xue
Yufei Xue
JLJiao Li
Jiao Li
YLYi Liu
Yi Liu
ZYZhou Ye
Zhou Ye
YZYi Zhou
Yi Zhou
This study evaluates and compares the mechanical behavior of two collagen membranes in an in vitro model simulating membrane-stabilized horizontal guided bone regeneration (GBR). Megreen® (bovine pericardium, BP) and Bio-Gide® (porcine dermis, PD) were tested under wet conditions. Two models were developed: (1) a balloon dilation test to assess the membrane's capability to accommodate bone graft material and (2) a bone graft compression model to evaluate tear resistance during graft compaction. In the tensile testing, BP demonstrated a significantly superior modulus of elasticity (146.71 ± 45.08 vs. 6.08 ± 2.66 MPa), maximum load tolerance (30.71 ± 8.42 vs. 4.49 ± 1.36 N), and tensile stress at maximum load (14.62 ± 4.01 vs. 1.61 ± 0.49 MPa; p < 0.001). Conversely, PD achieved high tensile extension at maximum load (6.32 ± 1.93 vs. 1.64 ± 0.32 mm) and percent tensile strain at maximum load (52.69 ± 16.03 vs. 13.63 ± 2.65%; p < 0.001). In the balloon dilation test, PD presented a slightly greater expansion diameter (4.43 ± 0.17 vs. 4.34 ± 0.05 mm; p = 0.047). In the compression model, BP significantly outperformed PD in maximum load (40.86 ± 4.54 vs. 7.90 (7.72-10.92) N) and displacement at maximum load (5.61 ± 0.60 vs. 3.65 ± 0.82 mm; p < 0.001). BP exhibited higher tensile strength and compression resistance, whereas PD showed greater deformability. These findings indicate distinct mechanical differences between the two collagen membranes under the tested conditions and may provide a mechanical basis for membrane selection in membrane-stabilized horizontal GBR.