Ricardo Augusto

Ricardo Augusto

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 May 2016 in Frontiers in Oncology
Verified
Journal Article
Open access
PDF file
GBGiuseppe Battistoni
Giuseppe Battistoni
JBJulia Bauer
Julia Bauer
TBTill T. Boehlen
Till T. Boehlen
FCFrancesco Cerutti
Francesco Cerutti
MCMary P. W. Chin
Mary P. W. Chin
VVVasilis Vlachoudis
Vasilis Vlachoudis
Onte Carlo (MC) codes are increasingly spreading in the hadrontherapy community due to their detailed description of radiation transport and interaction with matter. The suitability of a MC code for application to hadrontherapy demands accurate and reliable physical models capable of handling all components of the expected radiation field. This becomes extremely important for correctly performing not only physical but also biologically-based dose calculations, especially in cases where ions heavier than protons are involved. In addition, accurate prediction of emerging secondary radiation is of utmost importance in innovative areas of research aiming at in-vivo treatment verification. This contribution will address the recent developments of the FLUKA MC code and its practical applications in this field. Refinements of the FLUKA nuclear models in the therapeutic energy interval lead to an improved description of the mixed radiation field as shown in the presented benchmarks against experimental data with both 4 He and 12 C ion beams. Accurate description of ionization energy losses and of particle scattering and interactions lead to the excellent agreement of calculated depth-dose profiles with those measured at leading European hadron therapy centers, both with proton and ion beams. In order to support the application of FLUKA in hospital based environments, Flair, the FLUKA graphical interface, has been enhanced with the capability of translating CT DICOM images into voxel-based computational phantoms in a fast and well-structured way. The interface is capable of importing also radiotherapy treatment data described in DICOM RT standard.In addition the interface is equipped with an intuitive PET scanner geometry generator and automatic recording of coincidence events. Clinically similar cases will be presented both in terms of absorbed dose and biological dose calculations describing the various available features.

16 May 2014 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RARicardo Augusto
Ricardo Augusto
LBLeo Buehler
Leo Buehler
ZLZoe Lawson
Zoe Lawson
SMStefano Marzari
Stefano Marzari
MSMonika Stachura
Monika Stachura
CCCERN-MEDICIS collaboration
CERN-MEDICIS collaboration
About 50% of the 1.4 GeV CERN (European Organization for Nuclear Research, www.cern.ch) protons are sent onto targets to produce radioactive beams by online mass separation at the Isotope Separator Online Device (ISOLDE) facility, for a wide range of studies in fundamental and applied physics. CERN-MEDICIS is a spin-off dedicated to R&D in life sciences and medical applications. It is located in an extension of the Class A building presently under construction. It will comprise laboratories to receive the irradiated targets from a new station located at the dump position behind the ISOLDE production targets. An increasing range of innovative isotopes will thus progressively become accessible from the start-up of the facility in 2015 onward; for fundamental studies in cancer research, for new imaging and therapy protocols in cell and animal models and for pre-clinical trials, possibly extended to specific early phase clinical studies up to Phase I trials. Five hundred megabecquerel isotope batches purified by electromagnetic mass separation combined with chemical methods will be collected on a weekly basis. A possible future upgrade with gigabecquerel pharmaceutical-grade i.e., current good manufacturing practices (cGMP) batch production capabilities is finally presented.

2 December 2024 in EPJ Nuclear Sciences & Technologies
Verified
Journal Article
Open access
PDF file
FBFrancesca Ballarini
Francesca Ballarini
KBKonstantin Batkov
Konstantin Batkov
GBGiuseppe Battistoni
Giuseppe Battistoni
MBMaria Bisogni
Maria Bisogni
TBTill Tobias Tobias Böhlen
Till Tobias Tobias Böhlen
LZLorenzo Zana
Lorenzo Zana
The FLUKA Monte Carlo Radiation Transport and Interaction code package is widely used to simulate the interaction of particles with matter in a variety of fields, including high energy physics, space radiation, medical applications, radiation protection and shielding assessments, accelerator studies, astrophysical studies and well logging. This paper gives a brief overview of the FLUKA program and describes recent developments, in particular, improvements in the modelling of particle interactions and transport are described in detail. In addition, an overview of selected applications is given.

1 June 2016 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Open access
RARicardo Augusto
Ricardo Augusto
TMT.M. Mendonca
T.M. Mendonca
FWF. Wenander
F. Wenander
LPL. Penescu
L. Penescu
ROR. Orecchia
R. Orecchia
TST. Stora
T. Stora
Hadron therapy was first proposed in 1946 and is by now widespread throughout the world, as witnessed with the design and construction of the CNAO, HIT, PROSCAN and MedAustron treatment centres, among others. The clinical interest in hadron therapy lies in the fact that it delivers precision treatment of tumours, exploiting the characteristic shape (the Bragg peak) of the energy deposition in the tissues for charged hadrons. In particular, carbon ion therapy is found to be biologically more effective, with respect to protons, on certain types of tumours. Following an approach tested at NIRS in Japan [1], carbon ion therapy treatments based on 12C could be combined or fully replaced with 11C PET radioactive ions post-accelerated to the same energy. This approach allows providing a beam for treatment and, at the same time, to collect information on the 3D distributions of the implanted ions by PET imaging. The production of 11C ion beams can be performed using two methods. A first one is based on the production using compact PET cyclotrons with 10–20 MeV protons via 14N(p,α)11C reactions following an approach developed at the Lawrence Berkeley National Laboratory [2]. A second route exploits spallation reactions 19F(p,X)11C and 23Na(p,X)11C on a molten fluoride salt target using the ISOL (isotope separation on-line) technique [3]. This approach can be seriously envisaged at CERN-ISOLDE following recent progresses made on 11C+ production [4] and proven post-acceleration of pure 10C3/6+ beams in the REX-ISOLDE linac [5]. Part of the required components is operational in radioactive ion beam facilities or commercial medical PET cyclotrons. The driver could be a 70 MeV, 1.2 mA proton commercial cyclotron, which would lead to 8.1 × 10711C6+ per spill. This intensity is appropriate using 11C ions alone for both imaging and treatment. Here we report on the ongoing feasibility studies of such approach, using the Monte Carlo particle transport code FLUKA [6,7] to simulate pristine Bragg Peaks of 11C, in order to compare its performance with 12C, in the context of hadron therapy

1 June 2016 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Open access
João Pedro RamosJoão Pedro Ramos
João Pedro Ramos
AGA. Gottberg
A. Gottberg
RARicardo Augusto
Ricardo Augusto
TMT.M. Mendonca
T.M. Mendonca
KRK. Riisager
K. Riisager
TST. Stora
T. Stora
Five different nanostructured target materials were tested and operated at ISOLDE in the year of 2014, three of them being carbon-based nanocomposites. In most cases such target materials have higher radioisotope intensities than standard targets and with apparently longer release characteristics. Here, an isotope release profile from a standard calcium oxide (CaO) powder target is compared to the nanostructured one. For all target materials, the synthesis is the key process since it determines the material characteristics and maximum operation temperature which, in turn, defines the final isotope yields (especially for exotic isotopes). An unexpected release of Ar isotopes from a nanometric CaO powder target, with its oven set to room temperature is described and a release mechanism is proposed: spallation recoil momentum from the natCa(p,x)35Ar reaction

1 October 2018 in Physica Medica
Verified
Journal Article
Open access
RARicardo Augusto
Ricardo Augusto
JBJ. Bauer
J. Bauer
OBO. Bouhali
O. Bouhali
CCC. Cuccagna
C. Cuccagna
CGC. Gianoli
C. Gianoli
AFA. Ferrari
A. Ferrari
The new developments of the FLUKA Positron-Emission-Tomography (PET) tools are detailed. FLUKA is a fully integrated Monte Carlo (MC) particle transport code, used for an extended range of applications, including Medical Physics. Recently, it provided the medical community with dedicated simulation tools for clinical applications, including the PET simulation package. PET is a well-established imaging technique in nuclear medicine, and a promising method for clinical in vivo treatment verification in hadrontherapy. The application of clinically established PET scanners to new irradiation environments such as hadrontherapy requires further experimental and theoretical research to which MC simulations could be applied. The FLUKA PET tools, besides featuring PET scanner models in its library, allow the configuration of new PET prototypes via the FLUKA Graphical User Interface (GUI) Flair. Both the beam time structure and scan time can be specified by the user, reproducing PET acquisitions in time, in a particle therapy scenario. Furthermore, different scoring routines allow the analysis of single and coincident events, and identification of parent isotopes generating annihilation events. Two reconstruction codes are currently supported: the Filtered Back-Projection (FBP) and Maximum-Likelihood Expectation Maximization (MLEM), the latter embedded in the tools. Compatibility with other reconstruction frameworks is also possible. The FLUKA PET tools package has been successfully tested for different detectors and scenarios, including conventional functional PET applications and in beam PET, either using radioactive sources, or simulating hadron beam irradiations. The results obtained so far confirm the FLUKA PET tools suitability to perform PET simulations in R&D environment.