Vitamin K deficiency within neonates can result in vitamin K deficiency bleeding. Ensuring that newborns receive vitamin K is particularly critical in places where access to health care and blood products and transfusions is limited. The World Health Organization recommends that newborns receive a 1 mg intramuscular injection of vitamin K at birth. Evidence from multiple surveillance studies shows that the introduction of vitamin K prophylaxis reduces the incidence of vitamin K deficiency bleeding. Despite these recommendations, coverage of vitamin K prophylactic treatment in low-resource settings is limited. An intramuscular injection is the most common method of vitamin K administration in neonates. In low- and middle-income countries, needle sharing may occur, which may result in the spread of bloodborne diseases. The objective of our study was to investigate the manufacture of microneedles for the delivery of vitamin K. Following microneedle fabrication, we performed insertion studies to assess the microneedle's mechanical properties. Results indicate that vitamin K in a microneedle array was successfully delivered in vitro across neonatal porcine skin with 1.80 ± 0.08 mg delivered over 24 h. Therefore, this initial study shows that microneedles do have the potential to prevent vitamin K deficiency bleeding. Future work will assess delivery of vitamin K in microneedle array in vivo.
12 August 2021 in PLOS Neglected Tropical Diseases
Background: Glucose-6-phosphate dehydrogenase (G6PD) deficiency is a common enzyme deficiency, prevalent in many malaria-endemic countries. G6PD-deficient individuals are susceptible to hemolysis during oxidative stress, which can occur from exposure to certain medications, including 8-aminoquinolines used to treat Plasmodium vivax malaria. Accordingly, access to point-of-care (POC) G6PD testing in Brazil is critical for safe treatment of P. vivax malaria. Methodology/Principal findings: This study evaluated the performance of the semi-quantitative, POC STANDARD G6PD Test (SD Biosensor, Republic of Korea). Participants were recruited at clinics and through an enriched sample in Manaus and Porto Velho, Brazil. G6PD and hemoglobin measurements were obtained from capillary samples at the POC using the STANDARD and HemoCue 201+ (HemoCue AB, Sweden) tests. A thick blood slide was prepared for malaria microscopy. At the laboratories, the STANDARD and HemoCue tests were repeated on venous samples and a quantitative spectrophotometric G6PD reference assay was performed (Pointe Scientific, Canton, MI). G6PD was also assessed by fluorescent spot test. In Manaus, a complete blood count was performed. Samples were analyzed from 1,736 participants. In comparison to spectrophotometry, the STANDARD G6PD Test performed equivalently in determining G6PD status in venous and capillary specimens under varied operating temperatures. Using the manufacturer-recommended reference value thresholds, the test’s sensitivity at the <30% threshold on both specimen types was 100% (95% confidence interval [CI] venous 93.6%–100.0%; capillary 93.8%–100.0%). Specificity was 98.6% on venous specimens (95% CI 97.9%–99.1%) and 97.8% on capillary (95% CI 97.0%–98.5%). At the 70% threshold, the test’s sensitivity was 96.9% on venous specimens (95% CI 83.8%–99.9%) and 94.3% on capillary (95% CI 80.8%–99.3%). Specificity was 96.5% (95% CI 95.0%–97.6%) and 92.3% (95% CI 90.3%–94.0%) on venous and capillary specimens, respectively. Conclusion/Significance: The STANDARD G6PD Test is a promising tool to aid in POC detection of G6PD deficiency in Brazil. Trial registration: This study was registered with ClinicalTrials.gov (identifier: NCT04033640).
Glucose-6-phosphate dehydrogenase (G6PD) deficiency, an X-linked genetic disorder, is associated with increased risk of jaundice and kernicterus at birth. G6PD deficiency can manifest later in life as severe hemolysis, when the individual is exposed to oxidative agents that range from foods such as fava beans, to diseases such as typhoid, to medications such as dapsone, to the curative drugs for Plasmodium (P.) vivax malaria, primaquine and tafenoquine. While routine testing at birth for G6PD deficiency is recommended by the World Health Organization for populations with greater than 5% prevalence of G6PD deficiency and to inform P. vivax case management using primaquine, testing coverage is extremely low. Test coverage is low due to the need to prioritize newborn interventions and the complexity of currently available G6PD tests, especially those used to inform malaria case management. More affordable, accurate, point-of-care (POC) tests for G6PD deficiency are emerging that create an opportunity to extend testing to populations that do not have access to high throughput screening services. Some of these tests are quantitative, which provides an opportunity to address the gender disparity created by the currently available POC qualitative tests that misclassify females with intermediate G6PD activity as normal. In populations where the epidemiology for G6PD deficiency and P. vivax overlap, screening for G6PD deficiency at birth to inform care of the newborn can also be used to inform malaria case management over their lifetime.
12 October 2023 in PLOS Neglected Tropical Diseases
Introduction: Screening for G6PD deficiency can inform disease management including malaria. Treatment with the antimalarial drugs primaquine and tafenoquine can be guided by point-of-care testing for G6PD deficiency. Methods and findings: Data from similar clinical studies evaluating the performance of the STANDARD G6PD Test (SD Biosensor, South Korea) conducted in Bangladesh, Brazil, Ethiopia, India, Thailand, the United Kingdom, and the United States were pooled. Test performance was assessed in a retrospective analysis on capillary and venous specimens. All study sites used spectrophotometry for reference G6PD testing, and either the HemoCue or complete blood count for reference hemoglobin measurement. The sensitivity of the STANDARD G6PD Test using the manufacturer thresholds for G6PD deficient and intermediate cases in capillary specimens from 4212 study participants was 100% (95% Confidence Interval (CI): 97.5%–100%) for G6PD deficient cases with 60% on the reference assay. The negative predictive value for females with G6PD activity >60% was 99.6% (95% CI 99.1%–99.8%) on capillary specimens. Sensitivity among 396 P. vivax malaria cases was 100% (69.2%–100.0%) for both deficient and intermediate cases. Across the full dataset, 37% of those classified as G6PD deficient or intermediate resulted from true normal cases. Despite this, over 95% of cases would receive correct treatment with primaquine, over 87% of cases would receive correct treatment with tafenoquine, and no true G6PD deficient cases would be treated inappropriately based on the result of the STANDARD G6PD Test. Conclusions: The STANDARD G6PD Test enables safe access to drugs which are contraindicated for individuals with G6PD deficiency. Operational considerations will inform test uptake in specific settings.
Background: Point-of-care glucose-6-phosphate dehydrogenase (G6PD) testing has the potential to make the use of radical treatment for vivax malaria safer and more effective. Widespread use of G6PD tests as part of malaria case management has been limited, in part due to due concerns regarding product usability, user training, and supervision. This study seeks to assess how well end users can understand the Standard™ G6PD Test (SD Biosensor, Suwon, South Korea) workflow, result output, and label after training. This will ultimately help inform test registration and introduction. Methods: Potential G6PD test users who provide malaria case management at three sites in Brazil, Ethiopia, and India were trained on the use of the SD Biosensor Standard G6PD Test and assessed based on their ability to understand the test workflow and interpret results. The assessment was done through a questionnaire, designed to assess product usability against key technical product specifications and fulfill regulatory evidence requirements. Any participant who obtained 85% or above correct responses to the questionnaire was considered to adequately comprehend how to use and interpret the test. Results: Forty-five participants, including malaria microscopists, laboratory staff, nurses, and community health workers took part in the study. Seventy-eight percent of all participants in the study (35/45) obtained passing scores on the assessment with minimal training. Responses to the multiple-choice questions indicate that most participants understood well the test intended use, safety claims, and warnings. The greatest source of error regarding the test was around the correct operating temperature. Most test results were also read and interpreted correctly, with the haemoglobin measurement being a more problematic output to interpret than the G6PD measurement. Conclusions: These data results show how a standardized tool can be used to assess a user’s ability to run a point-of-care diagnostic and interpret results. When applied to the SD Biosensor Standard G6PD Test, this tool demonstrates that a range of users across multiple contexts can use the test and suggests improvements to the test instructions and training that can improve product usability, increase user comprehension, and ultimately contribute to more widespread effective use of point-of-care G6PD tests. Trial registration: NCT04033640