To evaluate the effectiveness and safety of cryoballoon ablation (CBA) compared with radiofrequency ablation (RFA) for symptomatic paroxysmal or drug-refractory persistent atrial fibrillation (AF). Prospective cluster cohort study in experienced CBA and RFA centres. Primary endpoint was ‘atrial arrhythmia recurrence’, secondary endpoints were as follows: procedural results, safety, and clinical course. A total of 4189 patients were included: CBA 2329 (55.6%) and RFA 1860 (44.4%). Cryoballoon ablation population was younger, with fewer comorbidities. Procedure time was longer in the RFA group (P = 0.01). Radiation exposure was 2487 (CBA) and 1792 cGycm2 (RFA) (P < 0.001). Follow-up duration was 441 (CBA) and 511 days (RFA) (P < 0.0001). Primary endpoint occurred in 30.7% (CBA) and 39.4% patients (RFA) [adjusted hazard ratio (adjHR) 0.85, 95% confidence interval (CI) 0.70–1.04; P = 0.12). In paroxysmal AF, CBA resulted in a lower risk of recurrence (adjHR 0.80, 95% CI 0.64–0.99; P = 0.047). In persistent AF, the primary outcome was not different between groups. Major adverse cardiovascular and cerebrovascular event rates were 1.0% (CBA) and 2.8% (RFA) (adjHR 0.53, 95% CI 0.26–1.10; P = 0.088). Re-ablations (adjHR 0.46, 95% CI 0.34–0.61; P < 0.0001) and adverse events during follow-up (adjHR 0.64, 95% CI 0.48–0.88; P = 0.005) were less common after CBA. Higher rehospitalization rates with RFA were caused by re-ablations. The primary endpoint did not differ between CBA and RFA. Cryoballoon ablation was completed rapidly; the radiation exposure was greater. Rehospitalization due to re-ablations and adverse events during follow-up were observed significantly less frequently after CBA than after RFA. Subgroup analysis suggested a lower risk of recurrence after CBA in paroxysmal AF. ClinicalTrials.gov (NCT01360008), https://clinicaltrials.gov/ct2/show/NCT01360008.
1 January 2022 in Circulation: Arrhythmia and Electrophysiology
Background: Cryoballoon-based pulmonary vein isolation (PVI) has emerged as an effective treatment for atrial fibrillation. The most frequent complication during cryoballoon-based PVI is phrenic nerve injury (PNI). However, data on PNI are scarce. Methods: The YETI registry is a retrospective, multicenter, and multinational registry evaluating the incidence, characteristics, prognostic factors for PNI recovery and follow-up data of patients with PNI during cryoballoon-based PVI. Experienced electrophysiological centers were invited to participate. All patients with PNI during CB2 or third (CB3) and fourth-generation cryoballoon (CB4)-based PVI were eligible. Results: A total of 17 356 patients underwent cryoballoon-based PVI in 33 centers from 10 countries. A total of 731 (4.2%) patients experienced PNI. The mean time to PNI was 127.7±50.4 seconds, and the mean temperature at the time of PNI was −49±8°C. At the end of the procedure, PNI recovered in 394/731 patients (53.9%). Recovery of PNI at 12 months of follow-up was found in 97.0% of patients (682/703, with 28 patients lost to follow-up). A total of 16/703 (2.3%) reported symptomatic PNI. Only 0.06% of the overall population showed symptomatic and permanent PNI. Prognostic factors improving PNI recovery are immediate stop at PNI by double-stop technique and utilization of a bonus-freeze protocol. Age, cryoballoon temperature at PNI, and compound motor action potential amplitude loss >30% were identified as factors decreasing PNI recovery. Based on these parameters, a score was calculated. The YETI score has a numerical value that will directly represent the probability of a specific patient of recovering from PNI within 12 months. Conclusions: The incidence of PNI during cryoballoon-based PVI was 4.2%. Overall 97% of PNI recovered within 12 months. Symptomatic and permanent PNI is exceedingly rare in patients after cryoballoon-based PVI. The YETI score estimates the prognosis after iatrogenic cryoballoon-derived PNI. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03645577. Graphic A graphic abstract is available for this article.
Aims: To analyse outcomes of supraventricular tachycardia (SVT) ablations performed within a prospective German Ablation Quality Registry. Methods and results: Data from 12 566 patients who underwent catheter ablation of SVT between January 2007 and January 2010 to treat atrial fibrillation (AFIB, 37.2% of procedures), atrial flutter (AFL, 29.9%), atrioventricular nodal re-entrant tachycardia (AVNRT, 23.2%), atrioventricular re-entrant tachycardia (6.3%), and focal atrial tachycardia (AT, 3.4%) were prospectively collected. Patients were followed for at least 1 year. The periprocedural success rate was 96.3%, ranging from 84.3% (focal AT) to 98.9% (AVNRT). Kaplan–Meier mortality estimate at 1 year was 1.4% overall, and as high as 2.6% in the AFL group and 2.8% in the focal AT group. Recurrence of ablated or another symptomatic SVT was observed in 3783 (32.6%) of patients, ranging from 17.2% (AVNRT) to 45.6% (AFIB). Repeat ablation was performed in 12.0% of patients. After 1 year, 74.1% of survivors perceived ablation therapy as successful, 15.7% as partly successful, and 9.6% as unsuccessful. Even in those patients with arrhythmia recurrence, 76.0% perceived ablation as successful or partly successful and 89.6% would still undergo repeat ablation in the same institution. Conclusion: Ablation therapy for SVT is a safe procedure bringing symptomatic improvement and satisfaction to three quarters of patients after 1 year. Even in patients with arrhythmia recurrence, a high satisfaction level and adherence to the ablating institution could be documented. Strikingly high mortality and stroke rates in follow-up were observed in AFL patients, who apparently need consistent long-term anticoagulation and more medical attention.
1 April 2014 in Circulation: Arrhythmia and Electrophysiology
Background—: Cryoballoon (CB) ablation results in >70% freedom from atrial fibrillation at 1 year. Single-center data of the first (CBG1) and second (CBG2) cryoballoon, recently introduced, were analyzed to compare safety and efficacy. Methods and Results—: From March 2011 to December 2012, CB ablation with spiral mapping was performed consecutively in 484 patients with symptomatic atrial fibrillation. CBG1 was used in 364 of 484 (75%) and CBG2 in 120 of 484 (25%) patients. Periprocedural data were analyzed. Acute pulmonary vein (PV) isolation with CB only was achieved in 99.86% and 100% of veins with CBG1 and CBG2, respectively ( P =0.43). Number of applications until PV isolation decreased significantly with CBG2 (1.45±0.81 versus 1.28±0.64; P =0.001). Procedural, left atrial, and fluoroscopy time were reduced by −5%, −11%, and −15% ( P <0.05), respectively. Two balloons were used less frequently. Time to isolation decreased significantly with 23-mm (48 versus 33 seconds; P <0.0001) and 28-mm CBG2 (76 versus 52 seconds; P <0.0001). Early PV reconduction rarely occurred with CBG2 (2.6% versus 0.42%; P =0.0023). In-hospital atrial fibrillation recurrence rates were similar. Balloon temperatures were significantly warmer with 23-mm CBG2 and a trend for colder balloon temperature with 28-mm CBG2 were observed compared with their predecessors. Comparable low rates of phrenic nerve palsy were recorded (1.1% versus 1.7%; P =0.64). Esophageal temperatures were similar. Major complication rates were low (3.3% versus 3.33%; P =1.0). Conclusions—: CBG2 attains high rates of acute PV isolation within a significant faster and less complex procedure. Time to isolation is shorter, and PV isolation is achieved with fewer applications using CBG2. These enhancements were not at the cost of complications. Long-term success rates remain to be demonstrated.
Aims First-line ablation prior to antiarrhythmic drug (AAD) therapy is an option for symptomatic paroxysmal atrial fibrillation (PAF); however, the optimal ablation technique, radiofrequency (RF), or cryoballoon (CB) has to be determined. Methods and results The FREEZE Cohort Study compares RF and CB ablation. Treatment-naïve patients were documented in the FREEZEplus Registry. Periprocedural data and outcome were analysed. From 2011 to 2014, a total of 373/4184 (8.9%) patients with PAF naïve to AAD were identified. Pulmonary vein isolation (PVI) was performed with RF (n = 180) or CB (n = 193). In the RF group, patients were older (65 vs. 61 years, P < 0.01) compared with the CB group. The procedure time was significantly shorter and radiation exposure higher in the CB group. Major adverse events occurred in 1.6% (CB) and 3.7% (RF) of patients (P = 0.22). AF/atrial tachycardia (AT) recurrence until discharge was 4.5% (RF) and 8.5% (CB, P = 0.2). Follow-up (FU) ≥12 months was available in 99 (RF) and 107 (CB) patients. After 1.4 years of FU, freedom from AF/atrial tachycardia (AT) was 61% (RF) and 71% (CB, P = 0.11). In the RF group, more patients underwent cardioversion, and a trend for more repeat ablations was observed. Persistent phrenic nerve palsy was observed in one patient treated by CB. Conclusion First-line ablation for PAF is safe and effective with either RF or CB. The procedure was faster with the CB, but the radiation exposure was higher. Although there was a trend for more recurrences and complications in the RF group, a more favourable risk profile in patients undergoing CB ablation might have biased the results. ClinicalTrials.gov identifier NCT01360008.
19 May 2011 in Journal of Interventional Cardiac Electrophysiology