Marco Montemagno

Dr. Marco Montemagno

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
GTGianluca Testa
Gianluca Testa
MMMarco Montemagno
Marco Montemagno
AVAndrea Vescio
Andrea Vescio
GMGiuseppe Micali
Giuseppe Micali
RPRosario Emanuele Perrotta
Rosario Emanuele Perrotta
Vito PavoneVito Pavone
Vito Pavone
Background: Extracapsular femoral neck fractures (eFNF) are the third most common type of fracture in traumatology. Intramedullary nailing (IMN) is one of the most frequently used ortho-pedic treatments for eFNF. Blood loss is one of the main complications of this treatment. This study aimed to identify and evaluate the perioperative risk factors that lead to blood transfusion in frail patients with eFNF who undergo IMN. Methods: From July 2020 to December 2020, 170 eFNF-affected patients who were treated with IMN were enrolled and divided into two groups according to blood transfusion: NBT (71 patients who did not need a blood transfusion), and BT (72 patients who needed blood transfusion). Gender, age, BMI, pre-operative hemoglobin levels, in-ternational normalized ratio (INR) level, number of blood units transfused, length of hospital stay, surgery duration, type of anesthesia, pre-operative ASA score, Charlson Comorbidity Index, and mortality rate were assessed. Results: Cohorts differed only for pre-operatively Hb and surgery time (p < 0.05). Conclusion: Patients who have a lower preoperative Hb level and longer surgery time have a high blood-transfusion risk and should be closely followed peri-operatively.

Verified
Journal Article
Open access
PDF file
GTGianluca Testa
Gianluca Testa
SSSara De Salvo
Sara De Salvo
SBSilvia Boscaglia
Silvia Boscaglia
MMMarco Montemagno
Marco Montemagno
ALAntonio Longo
Antonio Longo
Vito PavoneVito Pavone
Vito Pavone
Background: Numerous studies have pointed out how visual impairment relates to falls in the elderly, causing dangerous consequences, such as fractures. The proximal femur fracture is one of the most frequent fracture types related to poor vision. This study investigates the link between fall-related hip fractures and visual impairment. Methods: The present is an observational monocentric case–control study. We collected the ophthalmologic anamnesis and measured the visual acuity of 88 subjects with femur neck fracture (case group), comparing it with 101 adults without fractures and a recent fall history. Results: The results showed no statistical difference between the two groups regarding visual acuity, with a p-value of 0.08 for the right eye and 0.13 for the left one. One of the major ophthalmologic morbidities found was cataracts, present in 48% of the control group and 30% of the case group. Conclusions: The data obtained suggest that visual impairment might not be crucial in determining falls in the elderly.

26 July 2024 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
RRRaffaele Russo
Raffaele Russo
AFAlberto Fontanarosa
Alberto Fontanarosa
MMMarco Montemagno
Marco Montemagno
AFAlfonso Fedele
Alfonso Fedele
ACAngelo De Crescenzo
Angelo De Crescenzo
RGRaffaele Garofalo
Raffaele Garofalo

Verified
Journal Article
Open access
PDF file
MMMarco Montemagno
Marco Montemagno
GTGianluca Testa
Gianluca Testa
FPFlora Maria Chiara Panvini
Flora Maria Chiara Panvini
GPGianluca Puglisi
Gianluca Puglisi
GPGiacomo Papotto
Giacomo Papotto
Vito PavoneVito Pavone
Vito Pavone
Augmented reality (AR) and 3D printing (3DP) are novel technologies in the orthopedic field. Over the past decade, enthusiasm for these new digital applications has driven new perspectives in improving diagnostic accuracy and sensitivity in the field of traumatology. Currently, however, it is still difficult to quantify their value and impact in the medical–scientific field, especially in the improvement of diagnostics in complex fractures. Acetabular fractures have always been a challenge in orthopedics, due to their volumetric complexity and low diagnostic reliability. Background/Objectives: The goal of this study was to determine whether these methods could improve the learning aspect and diagnostic accuracy of complex acetabular fractures compared to gold-standard CT (computed tomography). Methods: Orthopedic residents of our department were selected and divided into Junior (JUN) and Senior (SEN) groups. Associated fractures of acetabulum were included in the study, and details of these were provided as CT scans, 3DP models, and AR models displayed on a tablet screen. In a double-blind questionnaire, each resident classified every fracture. Diagnostic accuracy (DA), response time (RT), agreement (R), and confidence (C) were measured. Results: Twenty residents (JUN = 10, SEN = 10) classified five fractures. Overall DA was 26% (CT), 18% (3DP), and 29% (AR). AR-DA was superior to 3DP-DA (p = 0.048). DA means (JUN vs. SEN, respectively): CT-DA was 20% vs. 32% (p < 0.05), 3DP-DA was 12% vs. 24% (p = 0.08), and AR-DA was 28% vs. 30% (p = 0.80). Overall RT was 61.2 s (±24.6) for CT, 35.8 s (±20.1) for 3DP, and 46.7 s (±20.8) for AR. R was fairly poor between methods and groups. Overall, 3DPs had superior C (65%). Conclusions: AR had the same overall DA as CT, independent of experience, 3DP had minor differences in DA and R, but it was the fastest method and the one in which there was the most confidence. Intra- and inter-observer R between methods remained very poor in residents.

13 November 2024 in Injury
Verified
Journal Article
Closed access
Luigi TaralloLuigi Tarallo
Luigi Tarallo
MMMarco Montemagno
Marco Montemagno
MDMatilde Delvecchio
Matilde Delvecchio
LCLorenzo Costabile
Lorenzo Costabile
GPGiuseppe Porcellini
Giuseppe Porcellini
FCFabio Catani
Fabio Catani

Verified
Journal Article
Open access
PDF file
LLLudovico Lucenti
Ludovico Lucenti
GTGianluca Testa
Gianluca Testa
MMMarco Montemagno
Marco Montemagno
Marco SapienzaMarco Sapienza
Marco Sapienza
ARArcangelo Russo
Arcangelo Russo
Vito PavoneVito Pavone
Vito Pavone
The knowledge on the anatomy, function and biomechanics and the role of surgical procedures on the anterolateral ligament (ALL) of the knee is still controversial. Only a few papers have examined the ALL in children. The aim of this review is to analyze all the available literature about ALL in the pediatric population. Following the PRISMA criteria, the literature was systematically reviewed, examining all the articles about ALL in pediatric patients. Eight articles were involved in this study. Five cadaveric studies, two diagnostic studies, and one cross-sectional study were found. The identification of the ALL is not always possible in diagnostic studies using magnetic resonance (MRI) or in dissecting specimens. A high variability in the presence of the ligament and in its origin and insertion were found among the studies. It is more difficult to identify the ligament in younger patients than in older children, suggesting that its presence may develop at some point during the growth. Further studies are needed for a detailed knowledge of the ALL.