Jérôme Froger

Dr. Jérôme Froger


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Germain Valentin FaityGermain Valentin Faity
Germain Valentin Faity
DMDenis Mottet
Denis Mottet
JFJérôme Froger
Jérôme Froger
Kinematic analysis of the upper limbs is a good way to assess and monitor recovery in individuals with stroke, but it remains little used in clinical routine due to its low feasibility. The aim of this study is to assess the validity and reliability of the Kinect v2 for the analysis of upper limb reaching kinematics. Twenty-six healthy participants performed seated hand-reaching tasks while holding a dumbbell to induce behaviour similar to that of stroke survivors. With the Kinect v2 and with the VICON, 3D upper limb and trunk motions were simultaneously recorded. The Kinect assesses trunk compensations, hand range of motion, movement time and mean velocity with a moderate to excellent reliability. In contrast, elbow and shoulder range of motion, time to peak velocity and path length ratio have a poor to moderate reliability. Finally, instantaneous hand and elbow tracking are not precise enough to reliably assess the number of velocity peaks and the peak hand velocity. Thanks to its ease of use and markerless properties, the Kinect can be used in clinical routine for semi-automated quantitative diagnostics guiding individualised rehabilitation of the upper limb. However, engineers and therapists must bear in mind the tracking limitations of the Kinect.

14 November 2018 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
KBK. K. A. Bakhti
K. K. A. Bakhti
ILI. Laffont
I. Laffont
MMMark Muthalib
Mark Muthalib
JFJérôme Froger
Jérôme Froger
DMDenis Mottet
Denis Mottet
After a stroke, during seated reaching with their paretic upper limb, many patients spontaneously replace the use of their arm by trunk compensation movements, even though they are able to use their arm when forced to do so. We previously quantified this proximal arm non-use (PANU) with a motion capture system (Zebris, CMS20s). The aim of this study was to validate a low-cost Microsoft Kinect-based system against the CMS20s reference system to diagnose PANU. In 19 hemiparetic stroke individuals, the PANU score, reach length, trunk length, and proximal arm use (PAU) were measured during seated reaching simultaneously by the Kinect (v2) and the CMS20s over two testing sessions separated by two hours. Intraclass correlation coefficients (ICC) and linear regression analysis showed that the PANU score (ICC = 0.96, r2 = 0.92), reach length (ICC = 0.81, r2 = 0.68), trunk length (ICC = 0.97, r2 = 0.94) and PAU (ICC = 0.97, r2 = 0.94) measured using the Kinect were strongly related to those measured using the CMS20s. The PANU scores showed good test-retest reliability for both the Kinect (ICC = 0.76) and CMS20s (ICC = 0.72). Bland and Altman plots showed slightly reduced PANU scores in the re-test session for both systems (Kinect: − 4.25 ± 6.76; CMS20s: − 4.71 ± 7.88), which suggests a practice effect. We showed that the Kinect could accurately and reliably assess PANU, reach length, trunk length and PAU during seated reaching in post stroke individuals. We conclude that the Kinect can offer a low-cost and widely available solution to clinically assess PANU for individualised rehabilitation and to monitor the progress of paretic arm recovery. The study was approved by The Ethics Committee of Montpellier, France (N°ID-RCB: 2014-A00395–42) and registered in Clinical Trial (N° NCT02326688, Registered on 15 December 2014, https://clinicaltrials.gov/ct2/show/results/NCT02326688 ).

1 January 2014 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
CCChristine Azevedo Coste
Christine Azevedo Coste
JJJovana Jovic
Jovana Jovic
RPRoger Pissard-Gibollet
Roger Pissard-Gibollet
JFJérôme Froger
Jérôme Froger
Walking impairment after stroke can be addressed with the use of drop foot stimulators (DFS). Many studies have demonstrated that DFS improves walking speed, reduces spasticity and reduces the physiologic effort of walking. Current DFS, through activation of the common peroneal nerve, elicit ankle dorsiflexion during swing phase of gait. DFS are generally piloted by force sensing resistor placed in the shoe of the affected side with stimulation triggered ON by heel rise and triggered OFF by heel strike. A tilt sensor can also be used with stimulation triggered by the tilt of the shank of the affected leg. These triggering approaches are the standard for initiating stimulation. However, the real-time modulation of FES intensity to provide more optimized delivery of stimulation and also to regulate dorsiflexion in the presence of disturbances, such as fatigue and spasticity may increase the number of potential users of DFS. Concerning research domain, stimulators that would allow modulating the stimulation pattern in between heel rise and strike events would allow exploring new stimulation strategies. We propose to extract continuous information: the gait cycle index (GCI), from one inertial measurement unit (IMU) measuring shank tilt angle. In order to illustrate the use of this real-time information, we show the feasibility of piloting an electrical stimulator. 12 subjects with post-stroke hemiplegia participated. A wireless IMU was placed on the unaffected shank and was used to estimate GCI. Subjects performed 3 trials in each of the 3 conditions: C1 no stimulation aid, C2 electrical stimulation assistance triggered by heel switch, C3 electrical stimulation assistance triggered from GCI. 1) the proposed algorithm was able to real-time estimate GCI, 2) events could be extracted from GCI information in order to trig a DFS. The estimation of the continuous GCI in individuals with stroke is possible. Events can be extracted from this information in order to trig a stimulator. These results are a first step towards the possibility to investigate new DFS paradigms based on real-time modulation of stimulation parameters.

1 January 2015 in IFAC-PapersOnLine
Verified
Journal Article
Closed access
CCChristine Azevedo Coste
Christine Azevedo Coste
BENOIT SIJOBERTBENOIT SIJOBERT
BENOIT SIJOBERT
JFJérôme Froger
Jérôme Froger
CFCh. Fattal
Ch. Fattal

27 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Germain Valentin FaityGermain Valentin Faity
Germain Valentin Faity
YSYasmine Sidahmed
Yasmine Sidahmed
ILIsabelle Laffont
Isabelle Laffont
JFJérôme Froger
Jérôme Froger
Unilateral spatial neglect is a common sensorimotor disorder following the occurrence of a stroke, for which prismatic adaptation is a promising rehabilitation method. However, the use of prisms for rehabilitation often requires the use of specific equipment that may not be available in clinics. To address this limitation, we developed a new software package that allows for the quantification and rehabilitation of unilateral spatial neglect using immersive virtual reality. In this study, we compared the effects of virtual and real prisms in healthy subjects and evaluated the performance of our virtual reality tool (HTC Vive) against a validated motion capture tool. Ten healthy subjects were randomly exposed to virtual and real prisms, and measurements were taken before and after exposure. Our findings indicate that virtual prisms are at least as effective as real prisms in inducing aftereffects (4.39° ± 2.91° with the virtual prisms compared to 4.30° ± 3.49° with the real prisms), but that these effects were not sustained beyond 2 h regardless of exposure modality. The virtual measurements obtained with our software showed excellent metrological qualities (ICC = 0.95, error = 0.52° ± 1.18°), demonstrating its validity and reliability for quantifying deviation during pointing movements. Overall, our results suggest that our virtual reality software (Virtualis, Montpellier, France) could provide an easy and reliable means of quantifying and rehabilitating spatial neglect. Further validation of these results is required in individuals with unilateral spatial neglect.

21 December 2024 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
RGRonan Le Guillou
Ronan Le Guillou
JFJérôme Froger
Jérôme Froger
MMM. Morin
M. Morin
MCM. Couderc
M. Couderc
CCCamille Cormier
Camille Cormier
DGDavid Gasq
David Gasq
BackgroundStroke is the leading cause of acquired motor deficiencies in adults. Restoring prehension abilities is challenging for individuals who have not recovered active hand opening capacities after their rehabilitation. Self-triggered functional electrical stimulation applied to finger extensor muscles to restore grasping abilities in daily life is called grasp neuroprosthesis (GNP) and remains poorly accessible to the post-stroke population. Thus, we developed a GNP prototype with self-triggering control modalities adapted to the characteristics of the post-stroke population and assessed its impact on abilities.MethodsThrough two clinical research protocols, 22 stroke participants used the GNP and its control modalities (EMG activity of a pre-defined muscle, IMU motion detection, foot switches and voice commands) for 3 to 5 sessions over a week. The NeuroPrehens software interpreted user commands through input signals from electromyographic, inertial, foot switches or microphone sensors to trigger an external electrical stimulator using two bipolar channels with surface electrodes. Users tested a panel of 9 control modalities, subjectively evaluated in ease-of-use and reliability with scores out of 10 and selected a preferred one before training with the GNP to perform functional unimanual standardized prehension tasks in a seated position. The responsiveness and functional impact of the GNP were assessed through a posteriori analysis of video recordings of these tasks across the two blinded evaluation multi-crossover N-of-1 randomized controlled trials.ResultsNon-paretic foot triggering, whether from EMG or IMU, received the highest scores in both ease-of-use (median scores out of 10: EMG 10, IMU 9) and reliability (EMG 9, IMU 9) and were found viable and appreciated by users, like voice control and head lateral inclination modalities. The assessment of the system's general responsiveness combined with the control modalities latencies revealed median (95% confidence interval) durations between user intent and FES triggering of 333 ms (211 to 561), 217 ms (167 to 355) and 467 ms (147 to 728) for the IMU, EMG and voice control types of modalities, respectively. The functional improvement with the use of the GNP was significant in the two prehension tasks evaluated, with a median (95% confidence interval) improvement of 3 (- 1 to 5) points out of 5.ConclusionsThe GNP prototype and its control modalities were well suited to the post-stroke population in terms of self-triggering, responsiveness and restoration of functional grasping abilities. A wearable version of this device is being developed to improve prehension abilities at home.Trial Registration: Both studies are registered on clinicaltrials.gov: NCT03946488, registered May 10, 2019 and NCT04804384, registered March 18, 2021.ConclusionsThe GNP prototype and its control modalities were well suited to the post-stroke population in terms of self-triggering, responsiveness and restoration of functional grasping abilities. A wearable version of this device is being developed to improve prehension abilities at home.Trial Registration: Both studies are registered on clinicaltrials.gov: NCT03946488, registered May 10, 2019 and NCT04804384, registered March 18, 2021.