Tat-Thang LE

Dr. Tat-Thang LE

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
HTHai N. Tran
Hai N. Tran
TLTat-Thang LE
Tat-Thang LE
HJHyeonju Jeong
Hyeonju Jeong
SKSunju Kim
Sunju Kim
SCSewan Choi
Sewan Choi
In this article, one of the very first 800-V fuel cell DC–DC converter (FDC) is developed for the next-generation fuel cell electric vehicles. The higher boost gain ratio and switching loss associated with increasing dc-link voltage, along with gradually increasing power density and efficiency demanded in the next-generation EV power converters, make the conventional boost converter not suitable for 800-V FDC. This article proposes a new design approach in which a zero voltage transition (ZVT) high step-up dual floating output boost converter (DFOBC) is introduced. Due to higher voltage gain, the operating duty cycle of DFOBC is reduced and lies in the vicinity of D = 0.5, which reduces filter size. The ZVT cells greatly reduce switching losses at 300 kHz, which enables using only a single discrete SiC mosfet for the main switch of 25-kW module, contributing to volume and cost reduction. Moreover, the proposed converter successfully demonstrates the possibility of using planar core and printed circuit board (PCB) windings at 100-kW power level, which is rarely seen in previous works. Finally, a 25-kW prototype of the proposed ZVT DFOBC is built and test. The power density of 63 kW/L excluding heatsink is achieved. The peak and full-load efficiency are measured to be 99.0% and 97.7%, respectively.

9 March 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TLTat-Thang LE
Tat-Thang LE
Khai M. NguyenKhai M. Nguyen
Khai M. Nguyen
Truong-Duy DuongTruong-Duy Duong
Truong-Duy Duong
CWCaisheng Wang
Caisheng Wang
SCSewan Choi
Sewan Choi
Fault-tolerant methods have been recognized for improving the reliability of multiphase bidirectional dc–dc converters, including current-fed and voltage-fed dual active bridge converters. Fault-tolerant research for voltage-fed dual active bridge converters has caught much attention recently. In this article, a new fault-tolerant method for current-fed dual active bridge (CF-DAB) converters with blocking capacitors is proposed. The operation of the CF-DAB converter when an open-circuit fault occurs is comprehensively presented and analyzed. A frozen-phase fault-tolerant method with additional blocking capacitors on both sides of the transformer is proposed. The aim of the use of blocking capacitors is to block the dc current component of the high-frequency transformer, which could avoid the core saturation of the transformer. Also, the dc blocking capacitors help isolate the faulty phase when a frozen-phase fault-tolerant method is applied. The proposed method is shown to be a practical, simple, low loss, and effective solution for not only open-circuit fault isolation but also for shedding capability of the multiphase converter. The proposed concept could be applied for general multiphase current-fed converters. The experiment of a 6-kW prototype is implemented to confirm the proposed concept.

15 September 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JLJaeyeon Lee
Jaeyeon Lee
HJHyeonju Jeong
Hyeonju Jeong
TLTat-Thang LE
Tat-Thang LE
SCSewan Choi
Sewan Choi
In this article, a three-phase single-stage bidirectional ac–dc converter with low component count is proposed. The single-stage structure is configured by integrating a three-phase ac–dc converter and a three-phase dual active bridge converter. The power factor correction and bidirectional power control are performed by adjusting the modulation index of sinusoidal pulse width modulation (SPWM) and phase-shift angle between the primary and secondary bridges. The low-frequency components generated by SPWM are absorbed by fundamental blocking capacitors connected in series with transformer windings, resulting in true high-frequency isolation. The proposed converter can achieve soft-switching of all switching devices even in continuous conduction mode. A 110 Vac, 3 kW, 100 kHz prototype is implemented to validate the proposed concept and demonstrated 95.34% peak efficiency.

13 October 2023 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TLTat-Thang LE
Tat-Thang LE
JLJaeyeon Lee
Jaeyeon Lee
SCSewan Choi
Sewan Choi
In this article, a new single-stage bridgeless totem-pole ac–dc converter is proposed. The proposed converter is composed of two single-stage boost half-bridge ac–dc converters with the interleaved operation. Besides, while preserving the advantages of the L -type half-bridge-based single-stage totem-pole ac–dc converter, the proposed converter has the ability of phase-shedding operation, which helps to increase the total efficiency of the converter due to reduced switching and core losses by half under medium and light loads. A hybrid harmonic injection in phase shift and duty cycle according to battery voltage is proposed, which not only improves total harmonic distortion to smaller than 4% under the whole load range but also extends the zero-voltage switching range of the converter under a wide voltage range. The proposed control method can be utilized in the general dual-active-bridge-based single-stage converter. Experimental results from a 1.5-kW prototype are provided to validate the proposed concepts.

31 March 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
TLTat-Thang LE
Tat-Thang LE
SKSunju Kim
Sunju Kim
SCSewan Choi
Sewan Choi
In this article, a four-phase current-fed push–pull dual active bridge converter is proposed for applications requiring high power and a wide-voltage range. In addition to the conventional advantages of a small filter inductor, a small clamp capacitor, and low current stress in the primary switches due to the effect of four-phase interleaving, the proposed converter has a low total rms current of switches when operating at a wide-voltage range compared with the existing two- and three-phase converters. Also, the proposed converter was shown to be capable of the complete ZVS turn -on of all switches under a wide duty cycle range of 0.25–0.75 in both power-flow directions when small auxiliary inductors were added. A balanced four-phase transformer structure is proposed not only to cancel the dc-flux offset caused by the dc component of the primary winding current but also to reduce the core volume, footprint, and height of the transformer compared with the separated-core transformer. The experimental results from a 15-kW prototype are provided to validate the proposed concepts. The converter achieved a peak efficiency of 98% and maintained high efficiency when operated at a wide-voltage range.

29 January 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
TLTat-Thang LE
Tat-Thang LE
HJHyeonju Jeong
Hyeonju Jeong
SCSewan Choi
Sewan Choi
High-power isolated bidirectional dc-dc converters with wide voltage range are attracting increasing attention in many applications. The bidirectional three-phase current-fed DC-DC converters are known to be suitable for wide voltage range applications compared to DAB based converters, having advantages of reduced device current ratings and prevention of transformer saturation due to high impedance nature. However, when the duty cycle becomes lower than 0.33 or higher than 0.66, power transfer capability is limited, and the efficiency is significantly reduced due to increased circulating current, which has rarely been discussed so far. In this paper, a hybrid dual-asymmetrical PWM (DAPWM) and PWM plus phase-shift (PPS) switching method is proposed for efficiency improvement of the bidirectional three-phase push-pull converter with very wide voltage range. A seamless mode change method between PPS and DAPWM is also proposed for minimizing the transient state. Further, through current waveform and power flow analysis, the leakage inductance along with transformer turn ratio are designed to minimize the RMS current of devices, while having the capability of transferring the desired power and limiting the slew rate of transformer winding current under wide voltage range operation. Experimental results from a 22-kW prototype are provided to validate the proposed concept.