David Necas

Dr. David Necas

Faculty of Mechanical Engineering, Brno University of Technology, Technická 2896/2, 616 69 Brno, Czech Republic
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
DRDavid Rebenda
David Rebenda
MVMartin Vrbka
Martin Vrbka
PČPavel Čípek
Pavel Čípek
ETEvgeniy Toropitsyn
Evgeniy Toropitsyn
DNDavid Necas
David Necas
MHMartin Hartl
Martin Hartl
Hyaluronic acid (HA) injections represent one of the most common methods for the treatment of osteoarthritis. However, the clinical results of this method are unambiguous mainly because the mechanism of action has not been clearly clarified yet. Viscosupplementation consists, inter alia, of the improvement of synovial fluid rheological properties by injected solution. The present paper deals with the effect of HA molecular weight on the rheological properties of its solutions and also on friction in the articular cartilage model. Viscosity and viscoelastic properties of HA solutions were analyzed with a rotational rheometer in a cone–plate and plate–plate configuration. In total, four HA solutions with molecular weights between 77 kDa and 2010 kDa were tested. The frictional measurements were realized on a commercial tribometer Bruker UMT TriboLab, while the coefficient of friction (CoF) dependency on time was measured. The contact couple consisted of the articular cartilage pin and the plate made from optical glass. The contact was fully flooded with tested HA solutions. Results showed a strong dependency between HA molecular weight and its rheological properties. However, no clear dependence between HA molecular weight and CoF was revealed from the frictional measurements. This study presents new insight into the dependence between rheological and frictional behavior of the articular cartilage, while such an extensive investigation has not been presented before.

31 July 2022 in Advances in Colloid and Interface Science
Verified
Journal Article
Closed access
Max MarianMax Marian
Max Marian
Diana BermanDiana Berman
Diana Berman
DNDavid Necas
David Necas
NENazanin Emami
Nazanin Emami
Alessandro RuggieroAlessandro Ruggiero
Alessandro Ruggiero
Andreas RosenkranzAndreas Rosenkranz
Andreas Rosenkranz

15 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
DFDenis Furmann
Denis Furmann
DNDavid Necas
David Necas
DRDavid Rebenda
David Rebenda
PČPavel Čípek
Pavel Čípek
MVMartin Vrbka
Martin Vrbka
MHMartin Hartl
Martin Hartl
Articular cartilage ensures smooth motion of natural synovial joints operating at very low friction. However, the number of patients suffering from joint diseases, usually associated with cartilage degradation, continuously increases. Therefore, an understanding of cartilage tribological behaviour is of great interest in order to minimize its degradation, preserving the reliable function of the joints. The aim of the present study is to provide a comprehensive comparison of frictional behaviour of articular cartilage, focusing on the effect of synovial fluid composition (i), speed (ii), and load (iii). The experiments were realized using a pin-on-plate tribometer with reciprocating motion. The articular cartilage pin was loaded against smooth glass plate while the tests consisted of loading and unloading phases in order to enable cartilage rehydration. Various model fluids containing albumin, γ-globulin, hyaluronic acid, and phospholipids were prepared in two different concentrations simulating physiologic and osteoarthritic synovial fluid. Two different speeds, 5 mm/s and 10 mm/s were applied, and the tests were carried out under 5 N and 10 N. It was found that protein-based solutions exhibit almost no difference in friction coefficient, independently of the concentration of the constituents. However, the behaviour is considerably changed when adding hyaluronic acid and phospholipids. Especially when interacting with γ-globulin, friction coefficient decreased substantially. In general, an important role of the interaction of fluid constituents was observed. On the other hand, a limited effect of speed was detected for most of the model fluids. Finally, it was shown that elevated load leads to lower friction, which corresponds well with previous observations. Further study should concentrate on specific explored phenomena focusing on the detailed statistical evaluation.

22 February 2020 in Friction
Verified
Journal Article
Open access
PDF file
DNDavid Necas
David Necas
HUHatsuhiko Usami
Hatsuhiko Usami
TNTatsuya Niimi
Tatsuya Niimi
YSYoshinori Sawae
Yoshinori Sawae
IKIvan Krupka
Ivan Krupka
MHMartin Hartl
Martin Hartl
Hip joint replacements represent the most effective way of treatment for patients suffering from joint diseases. Despite the rapid improvement of implant materials over the last few decades, limited longevity associated with wear-related complications persists as the main drawback. Therefore, improved tribological performance is required in order to extend the service life of replacements. The effect of surface texturing of ultra-high molecular weight polyethylene (UHMWPE) acetabular cup was investigated in the present study. Unique tilling method was utilized for manufacturing the dimples with controlled diameter and depths on the contact surface of the cup. The experiments with four commercial femoral components and two model lubricants were realized. The main attention was paid to a coefficient of friction considering the differences between the original and the dimpled cups. Results showed remarkable lowering of friction, in general. Focusing on the simulated human synovial fluid, friction was reduced by 40% (alumina ceramic), 38.8% (zirconia toughened ceramic), 25.5% (metal), and 9.9% (oxinium). In addition, the dimples helped to keep the friction stable without fluctuations. To conclude, the paper brings a new insight into frictional behaviour of the hip replacements during running-in phase which is essential for overall implant lifespan. It is believed that proper surface texturing may rapidly improve the life quality of millions of patients and may lead to considerable financial savings.

1 April 2021 in Tribology International
Verified
Journal Article
Closed access
MMMax Marian
Max Marian
COChristian Orgeldinger
Christian Orgeldinger
Benedict RothammerBenedict Rothammer
Benedict Rothammer
DNDavid Necas
David Necas
MVMartin Vrbka
Martin Vrbka
SWSandro Wartzack
Sandro Wartzack

1 January 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
DNDavid Necas
David Necas
MVMartin Vrbka
Martin Vrbka
AGA. Galandáková
A. Galandáková
IKIvan Krupka
Ivan Krupka
MHM. Hartl
M. Hartl