Pavel Čípek

Mr. Pavel Čípek

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2020 in Materials
Verified
Journal Article
Open access
PDF file
DRDavid Rebenda
David Rebenda
MVMartin Vrbka
Martin Vrbka
PČPavel Čípek
Pavel Čípek
ETEvgeniy Toropitsyn
Evgeniy Toropitsyn
DNDavid Necas
David Necas
MHMartin Hartl
Martin Hartl
Hyaluronic acid (HA) injections represent one of the most common methods for the treatment of osteoarthritis. However, the clinical results of this method are unambiguous mainly because the mechanism of action has not been clearly clarified yet. Viscosupplementation consists, inter alia, of the improvement of synovial fluid rheological properties by injected solution. The present paper deals with the effect of HA molecular weight on the rheological properties of its solutions and also on friction in the articular cartilage model. Viscosity and viscoelastic properties of HA solutions were analyzed with a rotational rheometer in a cone–plate and plate–plate configuration. In total, four HA solutions with molecular weights between 77 kDa and 2010 kDa were tested. The frictional measurements were realized on a commercial tribometer Bruker UMT TriboLab, while the coefficient of friction (CoF) dependency on time was measured. The contact couple consisted of the articular cartilage pin and the plate made from optical glass. The contact was fully flooded with tested HA solutions. Results showed a strong dependency between HA molecular weight and its rheological properties. However, no clear dependence between HA molecular weight and CoF was revealed from the frictional measurements. This study presents new insight into the dependence between rheological and frictional behavior of the articular cartilage, while such an extensive investigation has not been presented before.

15 March 2020 in Materials
Verified
Journal Article
Open access
PDF file
DFDenis Furmann
Denis Furmann
DNDavid Necas
David Necas
DRDavid Rebenda
David Rebenda
PČPavel Čípek
Pavel Čípek
MVMartin Vrbka
Martin Vrbka
MHMartin Hartl
Martin Hartl
Articular cartilage ensures smooth motion of natural synovial joints operating at very low friction. However, the number of patients suffering from joint diseases, usually associated with cartilage degradation, continuously increases. Therefore, an understanding of cartilage tribological behaviour is of great interest in order to minimize its degradation, preserving the reliable function of the joints. The aim of the present study is to provide a comprehensive comparison of frictional behaviour of articular cartilage, focusing on the effect of synovial fluid composition (i), speed (ii), and load (iii). The experiments were realized using a pin-on-plate tribometer with reciprocating motion. The articular cartilage pin was loaded against smooth glass plate while the tests consisted of loading and unloading phases in order to enable cartilage rehydration. Various model fluids containing albumin, γ-globulin, hyaluronic acid, and phospholipids were prepared in two different concentrations simulating physiologic and osteoarthritic synovial fluid. Two different speeds, 5 mm/s and 10 mm/s were applied, and the tests were carried out under 5 N and 10 N. It was found that protein-based solutions exhibit almost no difference in friction coefficient, independently of the concentration of the constituents. However, the behaviour is considerably changed when adding hyaluronic acid and phospholipids. Especially when interacting with γ-globulin, friction coefficient decreased substantially. In general, an important role of the interaction of fluid constituents was observed. On the other hand, a limited effect of speed was detected for most of the model fluids. Finally, it was shown that elevated load leads to lower friction, which corresponds well with previous observations. Further study should concentrate on specific explored phenomena focusing on the detailed statistical evaluation.

30 April 2020 in Materials
Verified
Journal Article
Open access
PDF file
PČPavel Čípek
Pavel Čípek
MVMartin Vrbka
Martin Vrbka
DRDavid Rebenda
David Rebenda
DNDavid Necas
David Necas
IKIvan Krupka
Ivan Krupka
A healthy natural synovial joint is very important for painless active movement of the natural musculoskeletal system. The right functioning of natural synovial joints ensures well lubricated contact surfaces with a very low friction coefficient and wear of cartilage tissue. The present paper deals with a new method for visualization of lubricating film with simultaneous measurements of the friction coefficient. This can contribute to better understanding of lubricating film formation in a natural synovial joint. A newly developed device, a reciprocating tribometer, is used to allow for simultaneous measurement of friction forces with contact visualization by fluorescence microscopy. The software allowing for snaps processing and subsequent evaluation of fluorescence records is developed. The evaluation software and the follow-up evaluation procedure are also described. The experiments with cartilage samples and model synovial fluid are carried out, and the new software is applied to provide their evaluation. The primary results explaining a connection between lubrication and friction are presented. The results show a more significant impact of albumin proteins on the lubrication process, whereas its clusters create a more stable lubrication layer. A decreasing trend of protein cluster count, which corresponds to a decrease in the thickness of the lubrication film, is found in all experiments. The results highlight a deeper connection between the cartilage friction and the lubrication film formation, which allows for better understanding of the cartilage lubrication mechanism.

15 September 2019 in Tribology in Industry
Verified
Journal Article
Open access
PČPavel Čípek
Pavel Čípek
DRDavid Rebenda
David Rebenda
DNDavid Necas
David Necas
MVMartin Vrbka
Martin Vrbka
IKIvan Krupka
Ivan Krupka
MHM. Hartl
M. Hartl

19 December 2025 in Tribology International
Verified
Journal Article
Open access
LOLukáš Odehnal
Lukáš Odehnal
MRMatúš Ranuša
Matúš Ranuša
PČPavel Čípek
Pavel Čípek
MMMartin Malý
Martin Malý
VMVeronika Mazánová
Veronika Mazánová
MVMartin Vrbka
Martin Vrbka

30 December 2022 in Lubricants
Verified
Journal Article
Open access
PDF file
DRDavid Rebenda
David Rebenda
MRMatúš Ranuša
Matúš Ranuša
PČPavel Čípek
Pavel Čípek
ETEvgeniy Toropitsyn
Evgeniy Toropitsyn
MVMartin Vrbka
Martin Vrbka
Degradation of the articular cartilage (AC) structure due to osteoarthritis significantly influences its friction and lubrication mechanisms. Injection with exogenous hyaluronic acid (HA) is one of the ways to slow down the progress of these changes. The present paper aims to determine the effect of HA on the friction and lubrication processes of the synovial joint model. The main emphasis is placed on the effect of HA molecular weight (MW) on the coefficient of friction (COF) and the interactions between HA and other constituents of synovial fluid (SF). Frictional measurements between the AC surface and the glass were performed with simultaneous in situ observation of the contact zone by fluorescence microscopy. Using this methodology, a decrease in AC COF with an increase in the fluorescence intensity emitted from contact with HA was observed, while the phenomenon was found to be MW-dependent. These findings demonstrate that high-MW HA is more effective within a resumption of healthy AC lubrication due to a better adhesion to the AC surface.