Jianheng Sun

Jianheng Sun


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2023 in Structural Concrete
Verified
Journal Article
Closed access
XMXinxin Ma
Xinxin Ma
JSJianheng Sun
Jianheng Sun
RZRuolan Zhang
Ruolan Zhang
MYMingjing Yang
Mingjing Yang
ZMZhiliang Meng
Zhiliang Meng
FZFengshuang Zhang
Fengshuang Zhang

21 January 2023 in Case Studies in Construction Materials
Verified
Journal Article
Open access
XMXinxin Ma
Xinxin Ma
JSJianheng Sun
Jianheng Sun
FZFengshuang Zhang
Fengshuang Zhang
JYJing Yuan
Jing Yuan
ZMZhiliang Meng
Zhiliang Meng

17 June 2025 in Case Studies in Construction Materials
Verified
Journal Article
Open access
MYMingjing Yang
Mingjing Yang
JSJianheng Sun
Jianheng Sun
JYJing Yuan
Jing Yuan
HLHongbin Li
Hongbin Li
DXDa Xu
Da Xu
XMXinrui Ma
Xinrui Ma

31 March 2020 in International Journal of Heat and Technology
Verified
Journal Article
Closed access
WLWei Lu
Wei Lu
JWJunlin Wang
Junlin Wang
HGHua Guo
Hua Guo
HLHongmei Li
Hongmei Li
JSJianheng Sun
Jianheng Sun

20 March 2023 in Materials
Verified
Journal Article
Open access
PDF file
XMXinxin Ma
Xinxin Ma
JSJianheng Sun
Jianheng Sun
FZFengshuang Zhang
Fengshuang Zhang
JYJing Yuan
Jing Yuan
MYMingjing Yang
Mingjing Yang
KNKang min Niu
Kang min Niu
In this study, full iron tailings concrete (FITC) was created using iron tailings from a tailings pond in Qian’an, China. Iron tailings account for 86.8% of the total mass of solid raw materials in the FITC. To enable large-scale use of FITC, a comprehensive investigation of the structural behaviour of full-iron tailing-reinforced concrete (FITRC) specimens is warranted. Therefore, eight rectangular reinforced concrete (RC) columns with conventional reinforced concrete (CRC) as a control were tested to investigate the effects of section dimensions, initial eccentricities, and concrete strengths, on the structural behaviour of FITRC columns under large eccentric short-term loading. The experimental and analytical results indicated that the sectional strain of the FITRC columns satisfied the plane-section assumption under short-term loading, and the lateral deflection curve agreed well with the half-sinusoidal curve. In addition, the FITRC columns exhibited a slightly lower cracking load and lower ultimate load capacity than the CRC columns, and the crack widths were larger than those of the CRC columns. The reduction in the load capacity observed in the FITRC was within the permissible range stated in the design code, thereby satisfying the code requirements. The deformation coefficients of the FITRC and CRC columns were identical, and the cracking and ultimate loads calculated according to the current code and theories were in good agreement with the measured results.

4 December 2023 in Structural Concrete
Verified
Journal Article
Closed access
RCRuoyu Chen
Ruoyu Chen
YDYajing Duan
Yajing Duan
MYMingjing Yang
Mingjing Yang
JSJianheng Sun
Jianheng Sun